4) How would your calculated value of Ksn be affected by errors introduced from the following sources? Be specific in your answer. State whether Ksp Would be too large, too small, or not affected, and explain why that error would have that effect on Kep- The precipitate of Ca(IO3)2, when obtained originally, is not washed with distilled water. b The Na2S2O3 was not standardized, so its nominal molarity was used instead of a standardized molarity. Note that Na2S203 solutions can air oxidize over time. Although the KIO3 used to standardize the Na2S203 is labeled as 0.0100 M, its actual concentration is somewhat higher than 0.0100 M. Extraneous water is introduced from wet filter paper or wet funnels, or by washing the precipitate during the final filtration of Ca(IO3)2.

Appl Of Ms Excel In Analytical Chemistry
2nd Edition
ISBN:9781285686691
Author:Crouch
Publisher:Crouch
Chapter10: Potentiometry And Redox Titrations
Section: Chapter Questions
Problem 8P
icon
Related questions
Question
4) How would your calculated value of Ksn be affected by errors introduced from the following
sources? Be specific in your answer. State whether Ksp Would be too large, too small, or not
affected, and explain why that error would have that effect on Kep-
The precipitate of Ca(IO3)2, when obtained originally, is not washed with distilled water.
b The Na2S2O3 was not standardized, so its nominal molarity was used instead of a
standardized molarity. Note that Na2S203 solutions can air oxidize over time.
Although the KIO3 used to standardize the Na2S203 is labeled as 0.0100 M, its actual
concentration is somewhat higher than 0.0100 M.
Extraneous water is introduced from wet filter paper or wet funnels, or by washing
the precipitate during the final filtration of Ca(IO3)2.
Transcribed Image Text:4) How would your calculated value of Ksn be affected by errors introduced from the following sources? Be specific in your answer. State whether Ksp Would be too large, too small, or not affected, and explain why that error would have that effect on Kep- The precipitate of Ca(IO3)2, when obtained originally, is not washed with distilled water. b The Na2S2O3 was not standardized, so its nominal molarity was used instead of a standardized molarity. Note that Na2S203 solutions can air oxidize over time. Although the KIO3 used to standardize the Na2S203 is labeled as 0.0100 M, its actual concentration is somewhat higher than 0.0100 M. Extraneous water is introduced from wet filter paper or wet funnels, or by washing the precipitate during the final filtration of Ca(IO3)2.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 4 steps with 9 images

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Appl Of Ms Excel In Analytical Chemistry
Appl Of Ms Excel In Analytical Chemistry
Chemistry
ISBN:
9781285686691
Author:
Crouch
Publisher:
Cengage