A 3-phase, 48 kW, start-connected permanent magnet (PM) motor has a rated speed of 6600 rpm when supplied from a 110 Hz supply. The d-axis and q-axis inductances are La= 3.5mH and Lq= 4.7mH, respectively. The armature resistance and rotational losses are negligible. The motor operates without field weakening up to 6600 rpm, and a negative direct-axis current is imposed if the motor operates at speeds above 6600 rpm. The no-load terminal line-to-line voltage at 5000 rpm is 420 V (RMS). a. Determine the permanent magnet flux linkage.

Delmar's Standard Textbook Of Electricity
7th Edition
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Stephen L. Herman
Chapter35: Harmonics 916
Section: Chapter Questions
Problem 3RQ: Would a positive-rotating harmonic or a negative-rotating harmonic be more harmful to an induction...
icon
Related questions
Question
A 3-phase, 48 kW, start-connected permanent magnet (PM) motor has a rated speed of 6600
rpm when supplied from a 110 Hz supply. The d-axis and q-axis inductances are La= 3.5mH
and Lg= 4.7mH, respectively. The armature resistance and rotational losses are negligible.
The motor operates without field weakening up to 6600 rpm, and a negative direct-axis
current is imposed if the motor operates at speeds above 6600 rpm.
The no-load terminal line-to-line voltage at 5000 rpm is 420 V (RMS).
a. Determine the permanent magnet flux linkage.
b. Calculate the rated phase current.
c. Calculate the rated line to line voltage of the PM motor.
с.
d. At a speed of 7300 rpm, the PM motor operates in field weakening mode with a direct
axis current of -30A and produces a torque of 30 Nm. Determine the per-phase current
at this operating condition.
Transcribed Image Text:A 3-phase, 48 kW, start-connected permanent magnet (PM) motor has a rated speed of 6600 rpm when supplied from a 110 Hz supply. The d-axis and q-axis inductances are La= 3.5mH and Lg= 4.7mH, respectively. The armature resistance and rotational losses are negligible. The motor operates without field weakening up to 6600 rpm, and a negative direct-axis current is imposed if the motor operates at speeds above 6600 rpm. The no-load terminal line-to-line voltage at 5000 rpm is 420 V (RMS). a. Determine the permanent magnet flux linkage. b. Calculate the rated phase current. c. Calculate the rated line to line voltage of the PM motor. с. d. At a speed of 7300 rpm, the PM motor operates in field weakening mode with a direct axis current of -30A and produces a torque of 30 Nm. Determine the per-phase current at this operating condition.
Expert Solution
steps

Step by step

Solved in 4 steps

Blurred answer
Knowledge Booster
Three phase Induction Motor
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Electricity for Refrigeration, Heating, and Air C…
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning