b) A 300 MVA, 20 kV three-phase generator has a sub-transient reactance of 20%. The generator supplies a number of synchronous motors over 64 km transmission line having transformers at both ends, as shown in Figure 3. The motors, all rated 13.2 kV, are represented by just two equivalent motors. Rated inputs to the motors are 200 MVA and 100 MVA for M1 and M2, respectively. For both motors X" = 20%. The three-phase transformer T1 is rated 350 MVA, 230/20 kV with leakage reactance of 10%. Transformer T2 is composed of three single phase transformers each rated 127/13.2 kV, 100 MVA with leakage reactance of 10%. Series reactance of the transmission line is 0.50/km. M1 T2 k m r M2 Figure 3 Determine all impedances marked in per-unit and draw the per-unit per-phase impedances diagram. Select the generator rating as base in the generator circuit

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.45P: Figure 3.39 shows a oneline diagram of a system in which the three-phase generator is rated 300 MVA,...
icon
Related questions
Question
b) A 300 MVA, 20 kV three-phase generator has a sub-transient reactance of 20%. The generator
supplies a number of synchronous motors over 64 km transmission line having transformers at
both ends, as shown in Figure 3. The motors, all rated 13.2 kV, are represented by just two
equivalent motors. Rated inputs to the motors are 200 MVA and 100 MVA for M1 and M2,
respectively. For both motors X" = 20%. The three-phase transformer T1 is rated 350 MVA, 230/20
kV with leakage reactance of 10%. Transformer T2 is composed of three single phase transformers
each rated 127/13.2 kV, 100 MVA with leakage reactance of 10%. Series reactance of the
transmission line is 0.50/km.
p
M1
T1
T2
k
m
r
M2
Figure 3
Determine all impedances marked in per-unit and draw the per-unit per-phase impedances
diagram. Select the generator rating as base in the generator circuit
lle
Transcribed Image Text:b) A 300 MVA, 20 kV three-phase generator has a sub-transient reactance of 20%. The generator supplies a number of synchronous motors over 64 km transmission line having transformers at both ends, as shown in Figure 3. The motors, all rated 13.2 kV, are represented by just two equivalent motors. Rated inputs to the motors are 200 MVA and 100 MVA for M1 and M2, respectively. For both motors X" = 20%. The three-phase transformer T1 is rated 350 MVA, 230/20 kV with leakage reactance of 10%. Transformer T2 is composed of three single phase transformers each rated 127/13.2 kV, 100 MVA with leakage reactance of 10%. Series reactance of the transmission line is 0.50/km. p M1 T1 T2 k m r M2 Figure 3 Determine all impedances marked in per-unit and draw the per-unit per-phase impedances diagram. Select the generator rating as base in the generator circuit lle
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Synchronous Generator
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning