By how many volts will the potential of an ideal Mg2+ ion selective electrode (ISE) change if the electrode is removed from a 1.0 x 10-4 M solution of MgCl2 and placed in 1.0 x 10-3 M MgCl2?

Principles of Instrumental Analysis
7th Edition
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Chapter23: Potentiometry
Section: Chapter Questions
Problem 23.7QAP
icon
Related questions
Question
  1. By how many volts will the potential of an ideal Mg2+ ion selective electrode (ISE) change if the electrode is removed from a 1.0 x 10-4 M solution of MgCl2 and placed in 1.0 x 10-3 M MgCl2?

 

  1. 28 mL of 0.1M Ce4+ is mixed with 50 mL of 0.05M Fe2+. The solution potential is monitored with a Pt indicator electrode and an Ag/AgCl reference electrode. Calculate the potential of the Pt electrode and the cell potential.

 

                       

  1. An ion selective electrode for NO2- has the following values of Log k for the listed interferents.

 

 

                              Interferent                                     Logk

 

                              F-                                                   -3.1

                              SO42-                                             -4.1

                                I-                                                    -1.2

                                NO3-                                              -3.3

 

Which ion is the most serious interferent? Why? For what activity of this interferent is the potential (E) equivalent to a solution in

which aNO2- = 2.75 x 10-4 ?

 

     

  1. A glass and calomel electrode system was found to develop a potential of -0.0412V when dipped into a pH 6.00 buffer. When in an unknown solution, the cell potential was found to be -0.2004 V. Calculate the pH and the activity of hydrogen ion in the unknown solution.

 

  1. Suppose that when the cell potential for the unknown solution in # 3 was measured, the voltage reading was unstable and the values ranged from -0.1950 to -0.2020 V. Based on these data, estimate S/N for that electrode measurement system. Use absolute values in your calculation.

 

 

  1. A bare silver wire electrode is dipped into a solution 0.05M in KNO3 (supporting electrolyte) and saturated in AgBr (Ksp = 5.0 x 10-13), and connected to the back of an mV/pH meter along with a saturated calomel reference electrode. Calculate the potential of the silver indicator electrode. Calculate the cell potential.

 

 

                       

Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Electroanalytical Techniques
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
Appl Of Ms Excel In Analytical Chemistry
Appl Of Ms Excel In Analytical Chemistry
Chemistry
ISBN:
9781285686691
Author:
Crouch
Publisher:
Cengage
Fundamentals Of Analytical Chemistry
Fundamentals Of Analytical Chemistry
Chemistry
ISBN:
9781285640686
Author:
Skoog
Publisher:
Cengage