Chips of width L _ 15 mm on a side are mounted to a substrate that is installed in an enclosure whose walls and air are maintained at a temperature of Tsur=T∞=25oC. The chips have an emissivity of ε=0.60 and a maximum allowable temperature of Ts=85oC. (a) If heat is rejected from the chips by radiation and natural convection, what is the maximum operating power of each chip? The convection coefficient may be approximated as h=11.7 W/m2K. (b) If a fan is used to maintain airflow through the enclosure and heat transfer is by only forced convection, with h=250 W/m2K, what is the maximum operating power?
Chips of width L _ 15 mm on a side are mounted to a substrate that is installed in an enclosure whose walls and air are maintained at a temperature of Tsur=T∞=25oC. The chips have an emissivity of ε=0.60 and a maximum allowable temperature of Ts=85oC. (a) If heat is rejected from the chips by radiation and natural convection, what is the maximum operating power of each chip? The convection coefficient may be approximated as h=11.7 W/m2K. (b) If a fan is used to maintain airflow through the enclosure and heat transfer is by only forced convection, with h=250 W/m2K, what is the maximum operating power?
Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter48: Cooling Towers And Pumps
Section: Chapter Questions
Problem 11RQ: Vortexing in a cooling tower occurs in the A. inlet piping. B. basin of the tower. C. outlet piping....
Related questions
Question
Chips of width L _ 15 mm on a side are mounted to a substrate that is installed in an enclosure
whose walls and air are maintained at a temperature of Tsur=T∞=25oC. The chips have an emissivity of
ε=0.60 and a maximum allowable temperature of Ts=85oC.
(a) If heat is rejected from the chips by radiation and natural convection, what is the maximum operating
power of each chip? The convection coefficient may be approximated as h=11.7 W/m2K.
(b) If a fan is used to maintain airflow through the enclosure and heat transfer is by only forced
convection, with h=250 W/m2K, what is the maximum operating power?
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution!
Trending now
This is a popular solution!
Step by step
Solved in 4 steps
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning
International Edition---engineering Mechanics: St…
Mechanical Engineering
ISBN:
9781305501607
Author:
Andrew Pytel And Jaan Kiusalaas
Publisher:
CENGAGE L
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning
International Edition---engineering Mechanics: St…
Mechanical Engineering
ISBN:
9781305501607
Author:
Andrew Pytel And Jaan Kiusalaas
Publisher:
CENGAGE L