D-F. If the voltage rating is 2400 V, what is the current rating at each power factor? D) unity power factor a) 234.55 A b) 325 A c) 406.25 A d) none of the above E) 80 percent power factor a) 234.55 A b) 325 A c) 406.25 A d) none of the above F) 50 percent power factor a) 234.55 A b) 325 A c) 406.25 A d) none of the above

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter2: Fundamentals
Section: Chapter Questions
Problem 2.10P: For the circuit element of Problem 2.3, calculate (a) the instantaneous power absorbed, (b) the real...
icon
Related questions
Question
100%

7-

d.

e.

f.

 

B) 80 percent power factor?
a) 487.5 kW
- b) 780 kW
c) 975 kW
d) none of the above
C) 50 percent power factor?
a) 487.5 kW
b) 780 kW
c) 975 kW
d) none of the above
D-F.
If the voltage rating is 2400 V, what is the current rating at each power factor?
D) unity power factor
a) 234.55 A
b) 325 A
c) 406.25 A
d) none of the above
E) 80 percent power factor
a) 234.55 A
b) 325 A
c) 406.25 A
d) none of the above
F) 50 percent power factor
a) 234.55 A
b) 325 A
c) 406.25 A
d) none of the above
A three-phase 480-V 1200-kVA synchronous generator supplies rated load at a lagging power
factor of 75 percent. If the efficiency of the generator is 90 percent, what horsepower is the prime
mover delivering to the generator?
8.
a) 1201 hp
b) 1340 hp
c) 1787 hp
d) none of the above
Transcribed Image Text:B) 80 percent power factor? a) 487.5 kW - b) 780 kW c) 975 kW d) none of the above C) 50 percent power factor? a) 487.5 kW b) 780 kW c) 975 kW d) none of the above D-F. If the voltage rating is 2400 V, what is the current rating at each power factor? D) unity power factor a) 234.55 A b) 325 A c) 406.25 A d) none of the above E) 80 percent power factor a) 234.55 A b) 325 A c) 406.25 A d) none of the above F) 50 percent power factor a) 234.55 A b) 325 A c) 406.25 A d) none of the above A three-phase 480-V 1200-kVA synchronous generator supplies rated load at a lagging power factor of 75 percent. If the efficiency of the generator is 90 percent, what horsepower is the prime mover delivering to the generator? 8. a) 1201 hp b) 1340 hp c) 1787 hp d) none of the above
B) Current
a) 83.34 A
b) 144.34 A
c) 250 A
d) none of the above
C) kVA
a) 600 kVA
b) 1039.23 kVA
c) 1257 kVA
d) none of the above
A) Find the regulation of an AC generator that has a full-load voltage of 2400 V and no-load
voltage of 3240 V at 80 percent lagging power factor.
6.
a) 20 %
b) 27 %
-c) 35 %
d) none of the above
B) Will the percent regulation at unity power factor be larger than, smaller than, or the same as at
80 percent lagging power factor?
a) larger
b) smaller
c)
d)
same
none of the above
7.
What is the kilowatt rating of a three-phase 975-kVA generator at
A) unity power factor?
a) 487.5 kW
b) 780 kW
c) 975 kW
none of the above
d)
Transcribed Image Text:B) Current a) 83.34 A b) 144.34 A c) 250 A d) none of the above C) kVA a) 600 kVA b) 1039.23 kVA c) 1257 kVA d) none of the above A) Find the regulation of an AC generator that has a full-load voltage of 2400 V and no-load voltage of 3240 V at 80 percent lagging power factor. 6. a) 20 % b) 27 % -c) 35 % d) none of the above B) Will the percent regulation at unity power factor be larger than, smaller than, or the same as at 80 percent lagging power factor? a) larger b) smaller c) d) same none of the above 7. What is the kilowatt rating of a three-phase 975-kVA generator at A) unity power factor? a) 487.5 kW b) 780 kW c) 975 kW none of the above d)
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Voltage division method
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning