(d) Sketch and explain the transposition of 3- phase unsymmetrical transmission lines.
Q: An air lossless transmission line is operating at frequency of 3 MHz and has a length of 1.75 A,…
A: Given: An air lossless transmission line having Frequency, f=3 MHz Length, L=1.75 λ Characteristics…
Q: 11. The impedance on the Smith chart can be repeated for each half wavelength . length of the…
A: Lembda/2 line of the transmission line is called as impedance reflector because the value of…
Q: A single stub tuner is used to match a lossless transmission line of Z, = 75 Q to an antenna load…
A:
Q: A sinusoidal voltage wave is propagating on a low loss transmission line. The voltage as a function…
A: First calculate the wavelength of the signal by measuring the distance between two peaks.
Q: Problem 1. A parallel-wire air-spaced transmis- sion line operating at 1910 Hz has a phase shift of…
A: Given a parallel wire air spaced transmission line operating at, Frequency, f = 1910 Hz Phase shift,…
Q: Estimate the corona loss for a three-phase, 110 kV, 50 Hz, 150 km long transmission line consisting…
A: Introduction The solution can be achieved as follows. Solution
Q: A load with an impedance of 424.3045° N is connected to a 100 N lossless line. Using the Smith Chart…
A:
Q: A 30-m-long lossless transmission line with Z, = 50 0 operating at 2 MHz is terminated with a load…
A: The transmission lines have their own resistance, inductance and capacitance. The transmission lines…
Q: A single-phase antenna transmission line with a length of 40 km and the load supplying with a…
A: Given data, The value of the length of the line is 40 km, The supply voltage with load is 200kV, The…
Q: .A 3-phase, 220 k 50Hz transmission line consists of 1.5 cm radius conductor spaced 2 metres apart…
A: According to the question we have calculate corona loss per km of the line.
Q: From an antenna point of view, a two-wire transmission line can be considered as two wire antennas
A: Yes.
Q: A rectangular waveguide is terminated with an unknown load. By using a slotted line, load VSWR is…
A: VSWR : VSWR stands for voltage standing wave ratio is directly proportional to reflection…
Q: 3. Write down the conditions for RTE = RTM = 0. Under these conditions, a. for RTE, state what it…
A: Solution (a) : for the reflection coefficients ra0,k⊥ of the slabs at zero-frequency (the terms with…
Q: A load of 120 + j150 Ω is connected to a 60 Ω lossless line. Calculate the back reflection…
A: It is given that: ZL=12+j150 ΩZo=60 Ω
Q: A dispersionless transmission line is one which the wave velocity is not constant as a function of…
A: The above statement is absolutely correct
Q: A transmission line is not properly terminated thereby causing a a reflection coefficient magnitude…
A: In this question we need to find a impedance of the termination.
Q: The cutoff frequency for TE11 mode if the guide is filled with a lossless material having r = 2.25…
A:
Q: A transmission line has characteristic impedance of 75 Ω and it is connected to receiver with…
A: According to the question we have to find the value of i. Reflection Coefficient; ii. VSWR
Q: A 105MHz, 90 v peak signal is incident on a 50-ohm transmission line. The line is 125m long and is…
A:
Q: A 376-2 lossless air transmission line is connected to a complex load composed of a 749-N resistor…
A: We are authorized to answer one question at a time, since you have not mentioned which question you…
Q: A 702 high-frequency lossless line is used at a frequency where 2 = 80cm with a load of 140+j91 2 a.…
A:
Q: A piece of RG-59B/U Coaxial cable has a nominal capacitance of 0.4 F/m, and 7.5 H inductance per…
A:
Q: A load with an impedance of 424.30245° N is connected to a 100 N lossless line. Using the Smith…
A: The load impedance is given as, ZL=424.30∠45° ΩAnd The lossline impedance is,Zo=100 Ω
Q: A 3-phase, 60 Hz, 600 kV, lossless transmission line is 600 km long. The line inductance is 2…
A: Given- VL-L=600 kVf = 60 HzL = 2 mH/km/phaseC = 20 nF/km/phase To Find- Phase constant Surge…
Q: A 376-2 lossless air transmission line is connected to a complex load composed of a 749-2 resistor…
A:
Q: Derive an expression for sag in a transmission line of equal hight poles.
A: We have to derive formula of sag for equal height poles in a transmission line.
Q: c. A lossless 502line is terminated by a load Zı = 75 + j60 2. Using a Smith chart, determine (a)…
A: Given Zo = 50 ohm ZL = 75+j60 ohm
Q: Three phase, 260 kV, 50 Hz transmission line consists of 3.2 cm diameter conductor spaced 0.002 km…
A:
Q: Show that in a transmission line terminated with a pure positive reactive charge, the magnitude of…
A:
Q: sinusoidal voltage wave is propagating on a low loss transmission line. The voltage as a function of…
A:
Q: Which transmission medium is ideal for the most densely inhabited areas? Discuss
A: Transmission medium- Transmission Media are the communication channels through which data is…
Q: A lossless 50 transmission line was terminated with a load of = 17.7 + jl1.8N. The length of the…
A: The solution can be achieved as follows.
Q: Question#01: A piece of RG-59B/U Coaxial cable has a nominal capacitance of 0.9 Farad/meter, and 8…
A:
Q: The return loss for a Transmission line is 20 dB. What will be the value of the corresponding VSWR…
A: During transmission of signal through a transmission line, some portion of the signal always gets…
Q: A 100Ω lossless line connects a matched signal of 100kHz to a load of 25Ω. Calculate the reflection…
A:
Q: Antenna with impedance 40 +j30 2 is to be matched to a 100 Q lossless line with a shorted stub.…
A: Antenna with impedance 40+j30Ω is to be matched to a 100 Ω lossless line with a shorted…
Q: A 50Ω lossless transmission line is terminated in a load (50+j100) Ω. Using a smith chart, determine…
A: Given, Impedance, Z0=50ΩLoad Impedance, ZL =(50+j100)Ω
Q: Show work on smith chart find the shortest distance to match antenna 326+154J and transmission line…
A: Given ZL = 326+154J Z0 = 350 ohm Using single stub series matching we can find the minimum distance…
Q: ny two transmission mediums (twistted piars, coxial cable, microwave, satalitte, fiber optical).
A: Transmission medium is considered as the path of communication system that links the transmitter to…
Q: A 30-m-long lossless transmission line with Z, = 50 N operating at 2 MHz is termina with a load Z, =…
A: Reflection coefficients determine how much wave is is reflected at discontinuity of medium.It is…
Q: A 30-m-long lossless transmission line with Z, = 50 N operating at 2 MHz is terminated with a load…
A: Given Lossless transmission line Length l=30 mfrequency f=2 MHzZ0=50 Ωload ZL=60+j40 Ωu=0.6c
Q: Question # 01: A piece of RG-59B/U Coaxial cable has a 950 characteristic impedance and a nominal…
A: Given data, Characteristic impedance, Z=95 Ω Nominal capacitance, C=89 pF/m Diameter of the inner…
Q: What different types and modern usage areas of transmission lines and waveguides ? Explain and…
A: Transmission lines are used to transmit power from generating stations to distribution an dfrom…
Q: Antenna connected to a 150- lossless line, produces a standing wave ratio of 2.6. If measurements…
A: Given characteristic impedance is Zo=150 ohm Standing wave ratio S=2.6 Distance between two…
Q: A 50-ohm lossless transmission line is terminated by a 100-ohm resistive load and is operated at 100…
A:
Q: A 75 Q lossless transmission line is to be matched with a 100-j802 load using Single stub. Calculate…
A: Given :Z0=75 ΩZL=100-j80 ΩZL=128.06∠38.66° f=30 MHz
Q: A piece of RG-59B/U Coaxial cable has a nominal capacitance of 0.9 Farad/meter, and 8 Henry/m…
A:
Q: 4- Prove that the Transmission system behavior differs at low and high frequencies? *
A: At low frequencies, the transmission line can be dealt by normal network theory. The elements too…
Q: Answer the following questions with simple answer within few lines only. A. How many numbers of…
A: Hello. Since your question has multiple sub-parts, we will solve the first three sub-parts for you.…
Q: The distance from the load to the source moving on a lossless transmission line is 2.5 revolutions…
A: The transmission lines are used for power transmission from one place to another. The power system…
Step by step
Solved in 2 steps with 6 images
- In terms of line-to-line capacitance, the line-to-neutral capacitance of a single-phase transmission line is Same Twice One-halfA single-phase overhead transmission line consists of two solid aluminum conductors having a radius of 3 cm with a spacing 3.5 m between centers. (a) Determine the total line inductance in mH/m. (b) Given the operating frequency to be 60 Hz, find the total inductive reactance of the line in /km and in/mi. (c) If the spacing is doubled to 7 m, how does the reactance change?Find the inductive reactance per mile of a single-phase overhead transmission line operating at 60 Hz given the conductors to be Partridge and the spacing between centers to be 30 ft.
- A piece of RG-59B/U Coaxial cable has a nominal capacitance of 0.9 Farad/meter, and 8 Henry/m inductance per meter. The diameter of the inner conductor as 0.8m, and the dielectric constant of the insulation as 4. Find the diameter of the outer conductor in cm. Assume the line is a lossless line?A piece of RG-59B/U Coaxial cable has a nominal capacitance of 0.4F/m, and 7.5 H inductance per meter. The diameter of the inner conductor as 0.8m,and the dielectric constant of the insulation as 4.97. Find the diameter of the outer conductor in cm. Assume the line is a lossless line?A 15-km, 60Hz, single phase transmission line consists of two solid conductors, eachhaving a diameter of 0.8cm. If the distance between conductors is 1.25m, determine theinductance and reactance of the line
- A piece of RG-59B/U Coaxial cable has a nominal capacitance of 0.4 F/m, and 7.5 H inductance per meter. The diameter of the inner conductor as 0.8m, and the dielectric constant of the insulation as 4.97. Find the diameter of the outer conductor in cm. Assume the line is a lossless line?Any two transmission mediums (twistted piars, coxial cable, microwave, satalitte, fiber optical).A Three-Phase, 180 KV, 75 Hz Transmission Line consists of 1.2 cm radius conductors spaced at 2.4 meters apart in an equilateral triangular formation. If the Temperature is 40 ºC and Atmospheric Pressure is 76 cm of Hg, calculate the Corona Loss per km of the line. Take m0=0.8
- A load of 120 + j150 Ω is connected to a 60 Ω lossless line. Calculate the back reflection coefficient and voltage standing wave ratio (VSWR) values on the line, respectively. Choose the correct optionA transmission line has characteristic impedance of 75 Ω and it is connected to receiver with ??=100−?50 Ω, using smith chart to find:i. Reflection Coefficient;ii. VSWRDetermine the loop inductance, and the capacitance of a 1 km length of single-phase twin line having conductors of diameter 10 mm and spaced 800 mm apart in air.