Due to the fault at bus number -4 the Circuit breaker connected to the phase "B" starts functioning and it is found that fault current flows to the ground through a fault impedance of jo.02. [Take pre-fault current as 1.04 p.u.] (a) Name the Type of fault (b)Find all the maximum sequence currents that flows through the circuit Breaker The Z bus as shown below. j0.15 [j0.11 j0.12 j0.22 j0.26 j0.28 j0.30 j0.13 j0.26 j0.14 j0.15 j0.16 j0.32 j0.12 j0.13 j0.14 j0.161 j0.32 j0.33 j0.45 jo.35 j0.53 j0.28 j0.45 j0.55 j0.30 j0.35 j0.54 j0.66 j0.53 j0.56 j0.56 j0.67 j0.67 j0.77 j0.54 [j0.21 j0.22 j0.33 j0.36 j0.38 j0.23 j0.36 j0.24 j0.25 j0.26 j0.42 j0.25 j0.40 j0.26 j0.42 j0.46 j0.47 j0.57 j0.76 j 0.87 j0.22 j0.23 j0.24 j0.43 j0.45 j0.38 j0.45 j0.54 Z? j0.56 j0.40 j0.46 j0.56 j0.77 j0.47 j0.57 jo.76 j0.36 j0.32 j0.53 j0.54 j0.56 j0.67 0.87 [j0.31 j0.32 j0.33 j0.34 j0.32 j0.32 j0.26 j0.28 j0.30 j0.43 j0.45 j0.45 j0.65 j0.30 j0.35 j0.54 j0.76 j0.53 j0.56 j0.35 j0.33 j0.34 j0.35 j0.36 j0.32 j0.35 j0.26 j0.28 j0.67

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter10: System Protection
Section: Chapter Questions
Problem 10.25P
icon
Related questions
icon
Concept explainers
Question
Due to the fault at bus number -4 the Circuit breaker connected to the phase "B" starts
functioning and it is found that fault current flows to the ground through a fault impedance of
j0.02. [Take pre-fault current as 1.04 p.u.]
(a) Name the Type of fault
(b)Find all the maximum sequence currents that flows through the circuit Breaker
The Z bus as shown below.
[j0.11
j0.12
j0.13
j0.14
j0.15
j0.16 j0.32
j0.12 j0.13 j0.14
j0.26 j0.28
j0.33 j0.45
j0.45 j0.55
j0.30 j0.35 j0.54
j0.53 j0.56
j0.15
j0.30
j0.35
j0.54
j0.66
j0.67
j0.16-
j0.32
j0.53
j0.56
j0.67
j0.77
j0.22
j0.26
j0.28
[j0.21
j0.22
j0.23
j0.24
j0.25
j0.26 j0.42
j0.22
j0.33
j0.36
j0.38
j0.23 j0.24
j0.36 j0.38
j0.43 j0.45
j0.45 j0.54
j0.40 j0.46 j0.56
j0.47 j0.57
j0.26
j0.42
j0.25
j0.40
j0.46 j0.47
j0.56
j0.77
j0.76
j0.57
j0.76
j 0.87
[J0.31
j0.32
j0.33
j0.34
j0.35
j0.36 j0.32
j0.32 j0.33 j0.34
j0.26 j0.28
j0.43 j0.45
j0.45 j0.65
j0.30 j0.35 j0.54 j0.76
j0.53 j0.56
j0.35
j0.30
j0.35
j0.54
j0.36
j0.32
j0.53
j0.56
j0.67
j0.32
j0.26
j0.28
j0.67
0.87
Transcribed Image Text:Due to the fault at bus number -4 the Circuit breaker connected to the phase "B" starts functioning and it is found that fault current flows to the ground through a fault impedance of j0.02. [Take pre-fault current as 1.04 p.u.] (a) Name the Type of fault (b)Find all the maximum sequence currents that flows through the circuit Breaker The Z bus as shown below. [j0.11 j0.12 j0.13 j0.14 j0.15 j0.16 j0.32 j0.12 j0.13 j0.14 j0.26 j0.28 j0.33 j0.45 j0.45 j0.55 j0.30 j0.35 j0.54 j0.53 j0.56 j0.15 j0.30 j0.35 j0.54 j0.66 j0.67 j0.16- j0.32 j0.53 j0.56 j0.67 j0.77 j0.22 j0.26 j0.28 [j0.21 j0.22 j0.23 j0.24 j0.25 j0.26 j0.42 j0.22 j0.33 j0.36 j0.38 j0.23 j0.24 j0.36 j0.38 j0.43 j0.45 j0.45 j0.54 j0.40 j0.46 j0.56 j0.47 j0.57 j0.26 j0.42 j0.25 j0.40 j0.46 j0.47 j0.56 j0.77 j0.76 j0.57 j0.76 j 0.87 [J0.31 j0.32 j0.33 j0.34 j0.35 j0.36 j0.32 j0.32 j0.33 j0.34 j0.26 j0.28 j0.43 j0.45 j0.45 j0.65 j0.30 j0.35 j0.54 j0.76 j0.53 j0.56 j0.35 j0.30 j0.35 j0.54 j0.36 j0.32 j0.53 j0.56 j0.67 j0.32 j0.26 j0.28 j0.67 0.87
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Knowledge Booster
Fault analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning