In induction type energy meter ,. is made up of Silicon Steel laminated assembly placed below the Aluminum disc. permanent magnet ferro magnet series magnet shunt magnet
Q: Driving torque in electromagnetic induction relay is proportional to the square of current in-relay…
A: TRUE
Q: A 10 kW, 250 V self-excited generator, when delivering rated load, has an armature circuit voltage…
A: The emf induced in a set of conductors due to relative space variation w.r.t steady magnetic field…
Q: entify the DC motor that can be used in conveyor. Also, explain the requirement of a DC Motor to be…
A: DC series motor is used for the conveyer dc series motor are those motor in which field winding and…
Q: Draw the equivalent circuits of Class E chopper for the different quadrant operation and write its…
A:
Q: A 30kW, 280V DC shunt machine has an armature and field resistances of 0.06Ω and 10Ω respectively.…
A:
Q: Q5. Explain the difference for the following paragraphs, answer five only A. Auto transformers and…
A: Convention transformer: This transformer is basically a two winding transformer or we can say that…
Q: Elimination of armature reaction requires a series field winding O True False
A: The elimination of armature reaction requires compensating winding.
Q: The open circuit characteristics of DC shunt generator starts with some * minimum voltage instead of…
A:
Q: Q: A 6-pole dc machine has 46 slots, 184 commutator segments, and 16 conductors per slot. It is…
A: We are authorized to answer three subparts at a time, since you have not mentioned which part you…
Q: Why we use silicon steel in manufacturing induction motor Core ? can we use wood in core…
A: In this question we will write about silicon steel use in making core of IM...
Q: CE1.3a Figure 1.16 shows a single robot joint/link driven through a gear ratio n by an…
A: 1. Input isarmature voltage VAtoutput isload shaft angle θLt
Q: Q\ Compare between Variable reluctance (VR) type and permanent magnet (PM) type and Hybrid type
A: permanent magnet motor is used to magnet imbedded into a surface of the motor rotor. it is used in a…
Q: Explain the improvement of transient stability by using turbine fast valving method.
A: Explain the improvement of transient stability by using turbine fast valving method.
Q: 1- Prove from the first principles an expression for the generated EMF at the armature of DC…
A:
Q: Using RHR-1, show that the emfs in the sides of the generator loop in Figure 23.23 are in the same…
A: Magnetic field is always run from north direction pole to south direction pole. If the current is…
Q: Explain the improvement of transient stability by using high speed excitation system
A: The transient stage operation of high power synchronous generator is dependent upon the excitation…
Q: Calculate the field copper loss at no -load and rated voltage for CW rotation of the armature and…
A:
Q: Draw the equivalent circuits of Class E chopper for the different quadrant operation and write its…
A: The following points should be remembered: 1. Positive Load Current = Current flows from source to…
Q: a shunt generator delivers a 195A at a terminal voltage of 250V. the armature resistance and shunt…
A: Given:-Vt=250VIL=195APF+W=950WRa=0.02ohmRsh=50ohm
Q: Draw and explain output characteristics of DC shunt generator
A: Concept: A capacity to do work is called energy and it may exist in potential, kinetic, thermal,…
Q: The relationship between field current and induced armature voltage is known as open circuit…
A: Given Field current and armature voltage is known as open circuit characteristics True or false
Q: What are the necessary conditions for voltage build-up in dc shunt generator ?
A: The necessary conditions for voltage build up in a dc shunt generator is given below: The…
Q: Decreasing the length of the air gap of DC machine reduces the Armature reaction effect. Select one:…
A: A Brief About Armature Reaction:- The effect of magnetic field produced on the main field flux is…
Q: 3-A long shunt compound DC generator delivers a load current of 50A at 500V and has armature, series…
A:
Q: Draw the circuit diagram of self excited DC shunt generator, mark all current and voltages and write…
A: A shunt generator is a type of direct current electric generator in which field winding and armature…
Q: > A 25 kW Shunt Generator generates terminal voltage at full load is 400V and has a resistances of…
A:
Q: Qi (a) With aid of suitable diagram, explain the losses and power-flow of an induction motor.
A: To know how the power flow in the case of an induction machine we need to draw power flow diagram.…
Q: QI) The induced voltage of a shunt generator is 254 V. When the machine is loaded, the terminal…
A: Step 1 Induced voltage E = 254 V Terminal voltage Vt = 240 V Armature resistance Ra = 0.04Ω…
Q: To ensure a successful voltage buildup, the self-excited dc generator must be started with a shunt…
A: The correct answer is option b, Lesser than the maximum slope of its magnetization curve. Critical…
Q: A 6-pole dcshuntgenerator with a wave - wound armature has 960 conductors. Itruns ata speed of 500…
A:
Q: question:- 1- For the induced electromotive force generated through commutator of 2-pole Works as…
A: a) In two pole armature when rotor rotate the according to Faraday's law of electromagnetic…
Q: A long shunt compound generator delivers a load current of 50A at 430V and has series, armature and…
A: Given: A long shunt compound generator Load current, I=50 A Terminal voltage, V=430 V Series…
Q: Discuss two design considerations when selecting a stepper motor.
A: When choosing a stepper motor for your application, it is important to analyze the motor’s…
Q: 3. Which of the following statements IS NOT CORRECT ? * for two motors with equal output power,…
A: Motor: It is an electromechanical device. this takes the electrical input and converts this power…
Q: Pls Explain the following Contrast DC motor types with DC generator
A: Types of DC motors: separately excited motor: The field winding of this motos is excited from an…
Q: resistance, R = 116mN. If the field windin armature resistance, Ra =45m2. Determine the following…
A:
Q: With suitable diagram explain the operation of a permanent magnet stepper motor.
A: The permanent magnet stepper motor is an electromechanical energy change device, which converts…
Q: Answe completely and elaborate complete details. No plagiarism 1.) Define the working principle of…
A: AC motor: The motor converts the electrical current into mechanical power. This type of motor is…
Q: torque equation of induct
A: Solution- Torque Equation- In induction relay torque equation, two magnetic fluxes ϕ1 & ϕ2 which…
Q: machine consists of 4-poles and operating at 1500 rpm. Its frequency of the induced emf in armature…
A:
Q: A 25 kW Shunt Generator generates terminal voltage 400V at full load and has resistances of field…
A: Given a shunt generator having, Po/p=25kWVT=400VRsh=200ΩRa=1.75ΩFriction & windage loss=600W
Q: O In order to exchange the output polarity of the induced electromotive force in the self-excited…
A: As per our guidelines, we are supposed to answer only one question. Kindly repost other questions as…
Q: With necessary sketch, Explain the mode of operation of chopper which is turn off due to external…
A: Given that Explain the mode of operation of chopper which is turn off due to external circuit's…
Q: With neat diagrams, explain the development and effects of armature reaction in an alternator.…
A: As you have asked many sub-questions, I will answer the first two questions. You can ask the…
Q: Which among the following is the major portion of the operating cost which can be controlled in a…
A: The power plants are used to generate electricity. This generation of electricity involves many…
Q: shunt generator with a capacity of 250 kW and a voltage of 250 V has an armature circuit resistance…
A: Given, A shunt generator has, Terminal voltage (Vt)= 250 V Output power (Pout) = 250 kW Armerture…
Q: What are differences in term of construction and working principle between Shaded Pole Induction…
A: The shaded pole motor and the capacitor start motor are the two types of single phase induction…
Q: -Why is the fall in the terminal voltage for the external chara, greater shunt generator than in…
A: The explanation is as follows.
Q: Describe the main advantage of GTO over thyristor.
A:
![In induction type energy meter
is made up of Silicon Steel laminated assembly placed below
the Aluminum disc.
permanent magnet
ferro magnet
O series magnet
shunt magnet](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2Fb01b1e7b-57a2-49be-9698-c07700a5ead1%2F8d24493b-28e7-420b-ba27-2ca6d36b04dd%2Fsqcnc2a_processed.png&w=3840&q=75)
![](/static/compass_v2/shared-icons/check-mark.png)
Step by step
Solved in 2 steps
![Blurred answer](/static/compass_v2/solution-images/blurred-answer.jpg)
- A magnetic circuit with a cross-sectional area of 20 cm? is to be operated at 50 Hz from a 120 V rms supply. The number of turns required to achieve a peak magnetic flux density of 1.8 T in the core isUntitled Section Jalis 6 In d.c. generators armature reaction is produced by field current O armature current commutating winding current none of the mentioned compensating winding current *.The use of d.c. generators eliminated the use of rectifiers and ac supplies True False ODifferentiate the two generators shown in Figure 1.6.1-1 and Figure 1.6.1-2. The output voltage can be controlled by the adjustment of the d.c. field Permanent Magnet Field Electro- Magnetic Field Magnetic Field (Flux) Magnetic Field (Flux) IN ADJUSTABLE D.C SUPPLY Shaft Shaft Copper loop Slip-rings and Brushes Çopper loop Slip-rings and Brushes THIS TIME THE MAGNETS ARE STATIONARY, BUT THE COIL IS MOVING! www Output Output Figure 1.6.1-1 Figure 1.6.1-2
- 1.Consider the magnetic core below.All dimensions are shown on the figure. The core is made up of legs with 2 different cross-sectional areas.The depth of core is 10cm.The relative permeability of the core is 2000. The current in the magnetising coil is 1 A. The number of turns of the coil is 2000.Calculate: (i)the reluctances and draw the magnetic circuit (ii)the flux in the core (iii)Flux densities B and field intensities H in legs having different cross-sectional areas. (iv)Verify Ampere's Law. Depth: 10 cm I=1A 20cm 2000 Turns 65cm 15cm 15cm 50cm 15cm ndo un ofHow voltage is built up in dc shunt generatorThe task is to draw or illustrate the armature winding, using the description below: -4 poles -26 conductors -double layer -simplex wave winding
- Using figures (a) and (b), a magnetic flux density of 0.1 Wb in the air gap Determine the current I in the coil with 200 turns required to produceArmature winding of an alternator can also be described asThe length of a magnetic circuit in a moving iron instrument is 300mm.The coil around the soft iron core has 360 turns and takes a current of 1.75A.The core is square in section with sides of 20mm.Take the relative permeability of soft iron as 1100. Determine the magnetomotive force in the core. Determine the field strength. Determine the flux density. Determine the total flux.
- What is the air gap flux?What characteristic is desirable in the B–H curve for a prospective material to be used in a permanent magnet? In a motor or transformer? Explain.What is use of solenoid coil in the pressure to converter? a. To produce magnetic field in the LVDT b. To change the LVDT output c. To bring back the pivoted beam normal position d. To produce linear displacement in bellows