LEASE GIVE COMPLETE AND DETAILED SOLUTION The oven shown in Figure 1 has a heating element, qi with capacitances C = 50 J/K. The corresponding temperature is T and ambient temperature is Ta. The thermal resistance of the oven wall is R = 2 K-s/J. The system has a steady-state error in the response, T(t) to a change in the reference input. The steady state error can be reduced if a proportional control action, Kp is included in the controller. Determine the range of values of Kp of the system so that the steady state error is lower than 0.4. (Hint: Kindly determine the steady state error at value 0.4)
LEASE GIVE COMPLETE AND DETAILED SOLUTION The oven shown in Figure 1 has a heating element, qi with capacitances C = 50 J/K. The corresponding temperature is T and ambient temperature is Ta. The thermal resistance of the oven wall is R = 2 K-s/J. The system has a steady-state error in the response, T(t) to a change in the reference input. The steady state error can be reduced if a proportional control action, Kp is included in the controller. Determine the range of values of Kp of the system so that the steady state error is lower than 0.4. (Hint: Kindly determine the steady state error at value 0.4)
Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter50: Commercial, Packaged Rooftop, Variable Refrigerant Flow, And Variable Air Volume Systems
Section: Chapter Questions
Problem 15RQ: Explain why the outside air damper is typically never completely closed, even when the outside air...
Related questions
Question
PLEASE GIVE COMPLETE AND DETAILED SOLUTION
The oven shown in Figure 1 has a heating element, qi with capacitances C = 50 J/K. The corresponding temperature is T and ambient temperature is Ta. The thermal resistance of the oven wall is R = 2 K-s/J. The system has a steady-state error in the response, T(t) to a change in the reference input. The steady state error can be reduced if a proportional control action, Kp is included in the controller. Determine the range of values of Kp of the system so that the steady state error is lower than 0.4.
(Hint: Kindly determine the steady state error at value 0.4)
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution!
Trending now
This is a popular solution!
Step by step
Solved in 2 steps
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning