Q2:- a synchronous generator is 25 MVA, 11kV, it is star- connected with the neutral point solidly grounded the generator is operating at no load rated voltage. Its reactances are X₁ = X₂ = 0.2 and Xo = 0.08 pu, calculate : a) The symmetrical sub transient line currents for SLG, LL, LLG and symmetrical three phase current. b) The value of reactance to be included in the generator neutral and grounded, so that line to ground fault current equals to the three phase fault current what will be the value of ground resistance to achieve the same condition ? c) With reactance value calculated in (b) included between neutral and ground. Calculate the line to line current and double line to ground fault current.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter6: Power Flows
Section: Chapter Questions
Problem 6.48P
icon
Related questions
Question
Q2:- a synchronous generator is 25 MVA, 11kV, it is star- connected with the neutral point solidly
grounded the generator is operating at no load rated voltage. Its reactances are X₁ = X₂ = 0.2 and
Xo = 0.08 pu, calculate :
a) The symmetrical sub transient line currents for SLG, LL, LLG and symmetrical three phase
current.
b) The value of reactance to be included in the generator neutral and grounded, so that line to
ground fault current equals to the three phase fault current what will be the value of ground
resistance to achieve the same condition ?
c) With reactance value calculated in (b) included between neutral and ground. Calculate the line
to line current and double line to ground fault current.
Transcribed Image Text:Q2:- a synchronous generator is 25 MVA, 11kV, it is star- connected with the neutral point solidly grounded the generator is operating at no load rated voltage. Its reactances are X₁ = X₂ = 0.2 and Xo = 0.08 pu, calculate : a) The symmetrical sub transient line currents for SLG, LL, LLG and symmetrical three phase current. b) The value of reactance to be included in the generator neutral and grounded, so that line to ground fault current equals to the three phase fault current what will be the value of ground resistance to achieve the same condition ? c) With reactance value calculated in (b) included between neutral and ground. Calculate the line to line current and double line to ground fault current.
Expert Solution
steps

Step by step

Solved in 4 steps

Blurred answer
Knowledge Booster
Three Phase Transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning