Q3/A/ For the three bus power system shown in Fig.(3), all the per unit reactances of its elements are scaled on a common MVA base and they are given as follow: G: 25 MVA, 11 kV, Xa =0.12p.u. M: 25 MVA, 6.6 kV, Xa =0.3 p.u. T1: 25 MVA, 11/66 kV, X= 0.09 p.u. T2: 25 MVA, 6.6/66 kV, X=0.08 p.u. T3: 25 MVA, 6.6/66 kV, X=0.08 p.u. Linel: 66 kV,X=0.2 pu: Line2: 66 kV, X=0.1 p.u. Bus 1 Bus 2 Bus 3 T2 Bus 4 Line 1 M uw T, Bus 5 Symmetrical three phase fault Line 2 Fig. (3) Bus 6 For a symmetrical three phase fault occurs at point F( at the mid point of line 1), find the fault current in amperes?

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter6: Power Flows
Section: Chapter Questions
Problem 6.52P
icon
Related questions
Question
i need ans within 15 minutes my best wishes ton
Q3/A/ For the three bus power system shown in Fig.(3), all the per unit reactances of its elements are
scaled on a common MVA base and they are given as follow:
G: 25 MVA, 11 kV, Xa =0.12p.u.
M: 25 MVA, 6.6 kV, Xa =0.3 p.u.
T: 25 MVA, 11/66 kV, X= 0.09 p.u.
T2: 25 MVA, 6.6/66 kV, X=0.08 p.u.
T3: 25 MVA, 6.6/66 kV, X=0.08 p.u.
Linel: 66 kV,X=0.2 pu:
Line2: 66 kV, X-0.1 p.u.
Bus 1
Bus 2
Bus 3
T2
Bus 4
Line 1
F
M
uw T3
Bus 5
Symmetrical
three phase fault
Line 2
Fig. (3)
Bus 6
For a symmetrical three phase fault occurs at point F( at the mid point of line 1), find the fault current
in amperes?
Transcribed Image Text:Q3/A/ For the three bus power system shown in Fig.(3), all the per unit reactances of its elements are scaled on a common MVA base and they are given as follow: G: 25 MVA, 11 kV, Xa =0.12p.u. M: 25 MVA, 6.6 kV, Xa =0.3 p.u. T: 25 MVA, 11/66 kV, X= 0.09 p.u. T2: 25 MVA, 6.6/66 kV, X=0.08 p.u. T3: 25 MVA, 6.6/66 kV, X=0.08 p.u. Linel: 66 kV,X=0.2 pu: Line2: 66 kV, X-0.1 p.u. Bus 1 Bus 2 Bus 3 T2 Bus 4 Line 1 F M uw T3 Bus 5 Symmetrical three phase fault Line 2 Fig. (3) Bus 6 For a symmetrical three phase fault occurs at point F( at the mid point of line 1), find the fault current in amperes?
Expert Solution
steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Diode-Transistor Logic Circuit
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning