SIL What is gradient elution? 412 List the variables in chromatography that lead to zone separation. 3 What would be the effect on a chromatographic peak of introducing the sample L at too slow a rate? 3-14 The following data are for a liquid chromatographic column Length of packing Flow rate 24.7 cm 0.313 mL/min 1.37 mL 0.164 mL A chromatogram of a mixture of species A, B, C, and D provided the following data: Retention Width of Peak Time, min Base (W), min Nonretained 3.1 A. 5.4 0.41 13.3 1.07 14.1 1.16 1.72 21.6 786 Chapter 26 An lotroduction to Chromatographic Separations Calculate (a) the number of plates from each peak. (b) the mean and the standard deviation for N. (c) the plate height for the column.

Principles of Instrumental Analysis
7th Edition
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Chapter26: An Introduction To Chromatographic Separations
Section: Chapter Questions
Problem 26.14QAP
icon
Related questions
Question
ONLY 26-11 26-14 Same questions just subpart
11 What is gradient elution?
12 List the variables in chromatography that lead to zone separation.
$3 What would be the effect on a chromatographic peak of introducing the sample
at too slow a rate?
3-14 The following data are for a liquid chromatographic column
Length of packing
Flow rate
24.7 cm
0.313 mL/min
1.37 mL
0.164 mL
A chromatogram of a mixture of species A, B, C, and D provided the following
data:
Retention
Width of Peak
Time, min
Base (W), min
Nonretained
3.1
5.4
0.41
B
13.3
1.07
14.1
1.16
D
21.6
1.72
786 Chapter 26 An louroduction to Chromatographic Separati
Calculate
(a) the number of plates from cach peak.
(b) the mean and the standard deviation for N.
(c) the plate height for the column.
Transcribed Image Text:11 What is gradient elution? 12 List the variables in chromatography that lead to zone separation. $3 What would be the effect on a chromatographic peak of introducing the sample at too slow a rate? 3-14 The following data are for a liquid chromatographic column Length of packing Flow rate 24.7 cm 0.313 mL/min 1.37 mL 0.164 mL A chromatogram of a mixture of species A, B, C, and D provided the following data: Retention Width of Peak Time, min Base (W), min Nonretained 3.1 5.4 0.41 B 13.3 1.07 14.1 1.16 D 21.6 1.72 786 Chapter 26 An louroduction to Chromatographic Separati Calculate (a) the number of plates from cach peak. (b) the mean and the standard deviation for N. (c) the plate height for the column.
Expert Solution
steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Analytical Separations
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
Appl Of Ms Excel In Analytical Chemistry
Appl Of Ms Excel In Analytical Chemistry
Chemistry
ISBN:
9781285686691
Author:
Crouch
Publisher:
Cengage
Fundamentals Of Analytical Chemistry
Fundamentals Of Analytical Chemistry
Chemistry
ISBN:
9781285640686
Author:
Skoog
Publisher:
Cengage
EBK A SMALL SCALE APPROACH TO ORGANIC L
EBK A SMALL SCALE APPROACH TO ORGANIC L
Chemistry
ISBN:
9781305446021
Author:
Lampman
Publisher:
CENGAGE LEARNING - CONSIGNMENT