SP₂ SP₁ PV 8 6 4 2 A B 10 5 15 20 Figure 3 Process responses from a pressure control loop Time (s) i. Based on the process responses, identify the type of controller used (PI or PID) to produce Response A and Response B. Justify your answer. ii. Determine which controller provides better control performance in terms of the overshoot value. iii. If a proportional controller only is used in the control system, sketch the predicted process response of the controller by comparing it with process responses in Figure 3.

Electric Motor Control
10th Edition
ISBN:9781133702818
Author:Herman
Publisher:Herman
Chapter50: Dynamic And Regenerative Braking
Section: Chapter Questions
Problem 3SQ: Referring to Figure 501, what will happen if the controller is placed in the off position from a...
icon
Related questions
Question
b) Figure 3 shows process responses (Response A and Response B) from a pressure control
loop when the setpoint is changed from SP₁ to SP₂ by using 2 different controllers.
Transcribed Image Text:b) Figure 3 shows process responses (Response A and Response B) from a pressure control loop when the setpoint is changed from SP₁ to SP₂ by using 2 different controllers.
SP₂
SP₁
PV
8
6
4
2
A
B
5
15
20
Figure 3 Process responses from a pressure control loop
10
Time (s)
i. Based on the process responses, identify the type of controller used (PI or PID) to
produce Response A and Response B. Justify your answer.
ii. Determine which controller provides better control performance in terms of the
overshoot value.
iii. If a proportional controller only is used in the control system, sketch the predicted
process response of the controller by comparing it with process responses in
Figure 3.
Transcribed Image Text:SP₂ SP₁ PV 8 6 4 2 A B 5 15 20 Figure 3 Process responses from a pressure control loop 10 Time (s) i. Based on the process responses, identify the type of controller used (PI or PID) to produce Response A and Response B. Justify your answer. ii. Determine which controller provides better control performance in terms of the overshoot value. iii. If a proportional controller only is used in the control system, sketch the predicted process response of the controller by comparing it with process responses in Figure 3.
Expert Solution
steps

Step by step

Solved in 4 steps with 4 images

Blurred answer
Knowledge Booster
Routh Hurwitz Criteria
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Electric Motor Control
Electric Motor Control
Electrical Engineering
ISBN:
9781133702818
Author:
Herman
Publisher:
CENGAGE L