[Standardization] A 0.3045 g of CaCO3 primary standard was dissolved using concentrated HCI, evaporated to incipient dryness, and quantitatively transferred to a 250 mL volumetric flask and diluted to mark. A 10 mL of aliquot was then transferred to an Erlenmeyer flask, together with 5mL buffer and 5 drops of EBT indicator, and was used to standardize the EDTA titrant. The solution turned blue after the addition of 24.10 mL of EDTA. A blank correction was made and was determined to be 0.4 mL. [Analysis] A 30 mL unknown water sample was treated with 37.6 mL of EDTA. A blank correction was made and was determined to be 0.4 mL. What is the concentration of CaCO3 of the unknown water sample in ppm? (MW CaCO3 = 100.0869 g/mol)? A 644.11 ppm CaCO3 B) 637.27 ppm CaCO3 633.43 ppm CaCO3 626.71 ppm CaCO3
[Standardization] A 0.3045 g of CaCO3 primary standard was dissolved using concentrated HCI, evaporated to incipient dryness, and quantitatively transferred to a 250 mL volumetric flask and diluted to mark. A 10 mL of aliquot was then transferred to an Erlenmeyer flask, together with 5mL buffer and 5 drops of EBT indicator, and was used to standardize the EDTA titrant. The solution turned blue after the addition of 24.10 mL of EDTA. A blank correction was made and was determined to be 0.4 mL. [Analysis] A 30 mL unknown water sample was treated with 37.6 mL of EDTA. A blank correction was made and was determined to be 0.4 mL. What is the concentration of CaCO3 of the unknown water sample in ppm? (MW CaCO3 = 100.0869 g/mol)? A 644.11 ppm CaCO3 B) 637.27 ppm CaCO3 633.43 ppm CaCO3 626.71 ppm CaCO3
Chapter9: Complexometric And Precipitation Titrations
Section: Chapter Questions
Problem 17P
Related questions
Question
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 2 steps with 1 images
Follow-up Questions
Read through expert solutions to related follow-up questions below.
Follow-up Question
Which of the following statements about the BOD test is FALSE?
-
The standard test for BOD is the five-day (BOD5) test carried out in the dark at 20 °C
-
There is an indirect correlation between the BOD5 value and the level of organic pollutants.
-
BOD test measures the oxygen consumed by microorganisms as they break down organic material
-
BOD test is a simple an
Solution
by Bartleby Expert
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.Recommended textbooks for you