Bathroom 2022
.pdf
keyboard_arrow_up
School
Dunwoody College of Technology *
*We aren’t endorsed by this school
Course
2111
Subject
Electrical Engineering
Date
Dec 6, 2023
Type
Pages
6
Uploaded by JudgeMusic11748
ELEC 2111
Job 28 Bathroom
Possible Points
Total
Pre-Job
5
Design (Cable Layout)
5
Material List
5
Rough-In Inspection
10
Trim-Out/ Final Inspection
10
Post Job
5
Safety/Professionalism
5
Name: ____________________________________________________________________Date: ____________
Objectives: Upon the completion of this job, the student should be able to:
•
Create a material list of the material that are required for the following installation.
•
Design a working drawing utilizing the cable layout method for the installation.
•
Apply the NEC to a working condition and environment.
•
Understand the construction process as is reflected in the field.
•
Apply box fill calculation as specified in Article 314.
•
Correctly splice conductors and termination devices.
•
Troubleshoot and correct basic circuitry
•
Demonstrate professionalism, and communication skills.
References:
•
NEC
Instructions: This Job will be done in any of the framing members in the house, please consult the instructor
for direction.
•
Answer all the pre job questions at prior to starting the job.
•
Design a print with (Visio/CAD/ Hand) with customer
’
s specifications.
•
Make a material list
•
Pull a Permit (
Download and fill a permit from any city in the state requesting inspection.)
•
Post you permit in your job
•
Complete the rough-in and call for an inspection wear your tools and PPE.
•
Complete the trim-out/Final and call for an inspection wear your tools and PPE.
•
We will power your job during the final Inspection
•
Answer all the post job questions
•
Upon completion demo your job, and return all the part to the tool room
Pre Job
1.
What is the definition of adjacent?
2.
What is the minimum size branch circuit required to supply the receptacle outlets in a
bathroom?
Code reference_________________
3.
Bathroom receptacles are required to be ____________________protected.
Code reference________________
4.
At least one receptacle must be installed within _________________of the outside
edge of each basin in the bathroom.
Code reference_________________
5.
A Bathroom is an area that includes a basin and a
_________________________________
Code reference__________________
6.
Is a bathroom required to have AFCI protection?
Code reference__________________
7.
Can you utilize the same receptacle circuit for the lighting circuit in the bathroom?
Explain:
Code reference___________________
8.
Can you utilize the bathroom receptacle circuit for the hallway receptacle outside the
bathroom?
Code Reference: _____________
9.
Do all receptacles require GFCI protection in the bathroom? Explain
Code Reference: _____________
10.
Draw the symbol for a bathroom fan
Design
Every bathroom design is going to be different based upon the
customer’s
needs.
Ask the Instructor what the customer wants:
Please design a print based upon the information you have been given.
Dot paper link
https://stemsheets.com/math/pdf/dot-
paper/c3JjL2RvdC1wYXBlcitrcy82NDY0K28xLzYrbzIvMitvMy81K3ByLzI-3D
Notes:
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
- Access to all documents
- Unlimited textbook solutions
- 24/7 expert homework help
Related Questions
Messages
AA
Statement one
Training will allow you to
safely erect a mobile.
tower scaffold on any
ground surface condition.
and access the tower
both internal and
externally
Statement two
In windy conditions
placing sheeting around
the mobile tower scaffold
will protect the workers
on the tower
a) Statement two
is incorrect
b) Statement one
and two are
correct
c) Statement one
is correct and
statement two is
incorrect
d) Both
statements are
incorrect
actclass.co.uk
22
Questi
23
Questi
24
Questi
25
Questi
26
Questi
Submit Answers
Ć
arrow_forward
14: In a natural circulation solar water heater, collector has a glass cover on the top and an ________________ material at the bottom.
a.
Insulating
b.
Sheets
c.
Steel
d.
Tubes
15: text
____________ wind mill consists of narrow rims and wire spokes.
a.
Single bladed
b.
Vertical Axis
c.
Double bladed
d.
Multibladed
arrow_forward
schedules are typically provided to detail the circuits and overcurrent protection required for
listribution equipment.
Branch-circuit
- Outlet
C.
d.
ore distribution points for electrical in ....
Switch
Panelboard
arrow_forward
1.1 PV modules can be wired together in an array using ______ connections to increase voltage.
a. Terminating
b. Series
c. Parallel
d. AC
1.2 A PV module, also called a solar panel, is comprised of individual photovoltaic _______ wired and mounted together as an integrated unit.
a. Capsules
b. Compartments
c. Chips
d. Cells
1.3 A __________ system uses a storage system that stores the generated electricity so it can provide during times when the system’s panels are not receiving solar energy.
a. Direct coupled
b. Self regulating
c. Charge controlled
d. Indirectly connected
1. 4 __________ energy may have the potential to supply all of the world's energy needs, but at this time, it provides a very small percentage.
a. Coal
b. Natural Gas
c. Diesel
d. Solar
arrow_forward
A cable wire maybe coaxial or twisted. Coaxial costs 25 centavos per meter while twisted wire costs only 18 centavos. The soldering cost for coaxial wire is P1.30 per connection, for twisted wire P1.70. What length of cable run will make the cost of installing coaxial equal to that of the twisted wire. Assume that the number of soldered connection is 350.
ANSWER_____________m
arrow_forward
Draw a dysfunctional circuit. Why is the circuit not functional?
arrow_forward
1-Calculate the minimum and maximum protection for an A/C, its conductors(75 °C) and its grounding.
For the following values:
1- FLC compressor = 30 A
2- FLC condenser = 3 A
NEC LOOP
CONDUCTORS
440.33
440.34
CONDUCTORS 440.32
OCPDS
440.22(A)
440.35
OCPD
440.22(A)
+440.22(B)
OVERLOADS 440.52(A(1)
DISCONNECT 440.14
DISCONNECTING MEANS
440.14
•SEE Ex 1 TO 440.14
A/C UNIT
WITH SINGLE
COMPRESSOR
CONDUCTORS
440.32
440.33
CONDUCTORS
440.32
440.33
arrow_forward
1. A14/2 type copper used for a general lighting branch circuit. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 2.Three 8 AWG copper conductors with THHN insulation Installed in garage in electrical metallic tubing (EMT). The ambient temperature in the garage can reach as high as 110'F. All termination points for this circuit are rated 60'C. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 3.Four 4 AWG copper conductor with THWN insulation imstalled in EMT in a basement. All termination points are rated at 60'C.
Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 4. An 8/3 Type UF copper cable installed underground from a house to a detached garage to feed a 120/240-volt subpanel. All termination points are rated at 60'C.…
arrow_forward
H1. If you need to make a straight connection to splice two conductors (both size 4 AWG) together, whichof the following connection methods should you use?A. A pressure connectorB. A barrel crimpC. A butt crimpD. A wire nut
H2. A/An _______ is an insulating tube or sleeve that protects an electrical conductor where it passesthrough a hole.A. expansion fittingB. couplingC. gland nutD. bushing
H3. Conductors that are larger than AWG size 8 will come only as a/an _______ conductor.A. aluminumEnd of examB. coveredC. solidD. stranded
arrow_forward
Provide a picture on the following parts of electrical plan.
Location and Site Plans in a Drawing Sheet
Legend or Symbols or Electrical Symbols in a Drawing Sheet
General Notes and/or Specifications.
Electrical Layout.
Schedule of Loads
One Line Diagram
Title Block
arrow_forward
The term "____" is defined in NEC® Article 100 as "connected to establish electrical continuity and conductivity."
Select one:
A. BENDED (BENDING)
B. BONDED (BONDING)
C. SHUNTED (SHUNTING)
D. GROUNDED (GROUNDING)
arrow_forward
What assumptions can you make regarding the following receptacle wiring?
Check all that apply.
White neutral wire
Grounding
screw
Brass screw
terminal
Silver screw
terminal
Black hot
wire
Red hot wire
Grounding wires
Grounding
screw
terminal
O device is at end-of-run
device box does not need a ground connection
this is a split-circuit receptacle
neutral side receptacle tab must be removed
arrow_forward
1.
Question text
In solar module, minimum value of shunt resistance could be 300 Ohm.
Select one:
True
False
arrow_forward
QUESTION 3
We are running 3 wires and a ground in a RMC to a control panel with a 60 amp circuit breaker disconnect in the control panel. The conduit is run along the ceiling where the ambient air temperature is 100 degrees. The control panel feeds our secondary cooling pump. What size are the ungrounded conductors? All conductors have typeTHHN insulation.
arrow_forward
Electrical plants
Define the terms "Main column ." " Line ." " Protection earth " and "
Operating earth
arrow_forward
List the minimum trade size Type EMT for each of the following applications. (Objective 12-1)
Three 14 AWG THHN, four 12 AWG THHN ______
Three 12 AWG THHN, four 8 AWG TW ______
Five 12 AWG THW, three 10 AWG THWN, three 8 AWG THHN ______
arrow_forward
Question 6 B
Thevenin’s Theorem RL
what VTH RTH
Full explain this question very fast solution sent me step by step
Not:- Text typing work only and Don't ignore any part all part work u
arrow_forward
QUESTION 3
Pair up the correct descriptions with the codes written in Sketch for Arduino
: void setup ()
A. Run setup and set pin 13 to be an output
B. Run loop repetitively
C. Set pin 13 to high (LED on)
D. Delay for half a second, and then Set pin 13 to low (LED off)
pinMode (13, OUTPUT):
E, Delay for a full second
: Void loop 0
F. Complete one iteration of the loop, and run it again
G. Delay for 500 seconds, and then Set pin 13 to low (LED of)
H. Run loop once
: digitalWrite (13, HIGH):
edelay (500):
digitalWrite (13, LOW):
delay (1000);
arrow_forward
6. Ferrous metal raceways or enclosures are made with _______ content.A. brass or aluminumB. steel or brassC. aluminum or ironD. iron or steel
arrow_forward
1-Calculate the minimum and maximum protection for an A/C , its conductors(75 ºC) and its grounding. For the following values:1- FLC compressor = 30 A2- FLC condenser = 3 A
arrow_forward
An isolator is used to:
Select one:
a. To be mounted on towers for
insulation purpose
b. All of the above
c. to disconnect part of the system for
maintenance from live circuit
d. Insulate the wires to avoid
electrocution and short circuits
Clear my choice
arrow_forward
If the NEC provides a requirement to grounding equipment, it generally implies that there will be a direct connection to Earth of connection through a/an
A. Equipment grounding conductor
B. Bonding conductor
C. Grounding electrode conductor
D. Equipotential bonding conductor
arrow_forward
NEC identifies ____ types of rigid PVC conduit.
Select one:
A. FIVE
B. TEN
C. THREE
D. TWO
arrow_forward
To testing installation of grounds, the usual procedure is to connect one lead of the megohmmeter to one of the conductors, then the other lead is___.
A, connected to another conductor b, connected to the conduit or raceway c. Connected to a special grounding electrode on the megohmmeter d. Left unconnected
arrow_forward
The control circuit is used to detect and count the number of products being carried on an assembly line. When it counts five products, the circuit energizes a solenoid. The solenoid is energized for a period of two seconds and is then shunts off, causing it to retract?
Note: Correct and detailed answer will be Upvoted else downvoted. Thank you!
arrow_forward
45. A switch or circuit breaker can be used as both the controller and disconnecting means if
it
a. opens all ungrounded conductors as required by NEC 430.103
b. is protected by an overcurrent device in each ungrounded conductor
c. is manually operable, or both power and manually operable
d. All of these answers
arrow_forward
Conduits or raceways through which moisture may contact live parts shall be ---- at either or both ends
(a)sealed
(b)bushed
( c)a or b
(d)plugged
arrow_forward
Q2/Clearly identify which of the following
items are rotating and which of them are
stationary. (1) commutator segments and (2)
carbon brushes ? *
1 Add file
Submit
arrow_forward
Q22. (a). Mention any four items must be
available in the maintenance manual.
(b). Draw the diagram and explain the method
of half split diagnosis technique.
A- BI
E E
II
123
GO
arrow_forward
4.A. If a bonding jumper is installed from a grounded metal box to a grounding-type receptacle, the length ofthe bonding jumper will be betweenA. 2 and 4 feet.B. 2 and 4 inches.C. 6 and 10 feet.D. 6 and 10 inches.4.B. Why isn't solder permitted to be relied on for grounding electrode connections?A. The solder increases the chances of a ground-fault event occurring.B. The heat from the solder weakens the connection and exposes it to physical damage.C. The use of solder doesn't meet the requirements for corrosive influences.D. The connection's integrity can be negatively affected by heat during a ground-fault event.4>c. Which of the following statements about bonding is true?A. The strike terminals of a lightning protection system must be bonded to the building or structure grounding electrode system.B. Bonding requirements on the supply side of the service disconnect are less restrictive.C. Wire-type supply-side bonding jumpers are usually short in length and installed from the…
arrow_forward
A device used in kitchen serving hotels dining rooms club houses and restaurants is__________.
a.) Grease basin b.) Yard basin c.) Garage basin d.) Oil catch basin
arrow_forward
Explain the relevance of earthing and bonding in an electrical Installation.
arrow_forward
SEE MORE QUESTIONS
Recommended textbooks for you
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Related Questions
- Messages AA Statement one Training will allow you to safely erect a mobile. tower scaffold on any ground surface condition. and access the tower both internal and externally Statement two In windy conditions placing sheeting around the mobile tower scaffold will protect the workers on the tower a) Statement two is incorrect b) Statement one and two are correct c) Statement one is correct and statement two is incorrect d) Both statements are incorrect actclass.co.uk 22 Questi 23 Questi 24 Questi 25 Questi 26 Questi Submit Answers Ćarrow_forward14: In a natural circulation solar water heater, collector has a glass cover on the top and an ________________ material at the bottom. a. Insulating b. Sheets c. Steel d. Tubes 15: text ____________ wind mill consists of narrow rims and wire spokes. a. Single bladed b. Vertical Axis c. Double bladed d. Multibladedarrow_forwardschedules are typically provided to detail the circuits and overcurrent protection required for listribution equipment. Branch-circuit - Outlet C. d. ore distribution points for electrical in .... Switch Panelboardarrow_forward
- 1.1 PV modules can be wired together in an array using ______ connections to increase voltage. a. Terminating b. Series c. Parallel d. AC 1.2 A PV module, also called a solar panel, is comprised of individual photovoltaic _______ wired and mounted together as an integrated unit. a. Capsules b. Compartments c. Chips d. Cells 1.3 A __________ system uses a storage system that stores the generated electricity so it can provide during times when the system’s panels are not receiving solar energy. a. Direct coupled b. Self regulating c. Charge controlled d. Indirectly connected 1. 4 __________ energy may have the potential to supply all of the world's energy needs, but at this time, it provides a very small percentage. a. Coal b. Natural Gas c. Diesel d. Solararrow_forwardA cable wire maybe coaxial or twisted. Coaxial costs 25 centavos per meter while twisted wire costs only 18 centavos. The soldering cost for coaxial wire is P1.30 per connection, for twisted wire P1.70. What length of cable run will make the cost of installing coaxial equal to that of the twisted wire. Assume that the number of soldered connection is 350. ANSWER_____________marrow_forwardDraw a dysfunctional circuit. Why is the circuit not functional?arrow_forward
- 1-Calculate the minimum and maximum protection for an A/C, its conductors(75 °C) and its grounding. For the following values: 1- FLC compressor = 30 A 2- FLC condenser = 3 A NEC LOOP CONDUCTORS 440.33 440.34 CONDUCTORS 440.32 OCPDS 440.22(A) 440.35 OCPD 440.22(A) +440.22(B) OVERLOADS 440.52(A(1) DISCONNECT 440.14 DISCONNECTING MEANS 440.14 •SEE Ex 1 TO 440.14 A/C UNIT WITH SINGLE COMPRESSOR CONDUCTORS 440.32 440.33 CONDUCTORS 440.32 440.33arrow_forward1. A14/2 type copper used for a general lighting branch circuit. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 2.Three 8 AWG copper conductors with THHN insulation Installed in garage in electrical metallic tubing (EMT). The ambient temperature in the garage can reach as high as 110'F. All termination points for this circuit are rated 60'C. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 3.Four 4 AWG copper conductor with THWN insulation imstalled in EMT in a basement. All termination points are rated at 60'C. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 4. An 8/3 Type UF copper cable installed underground from a house to a detached garage to feed a 120/240-volt subpanel. All termination points are rated at 60'C.…arrow_forwardH1. If you need to make a straight connection to splice two conductors (both size 4 AWG) together, whichof the following connection methods should you use?A. A pressure connectorB. A barrel crimpC. A butt crimpD. A wire nut H2. A/An _______ is an insulating tube or sleeve that protects an electrical conductor where it passesthrough a hole.A. expansion fittingB. couplingC. gland nutD. bushing H3. Conductors that are larger than AWG size 8 will come only as a/an _______ conductor.A. aluminumEnd of examB. coveredC. solidD. strandedarrow_forward
- Provide a picture on the following parts of electrical plan. Location and Site Plans in a Drawing Sheet Legend or Symbols or Electrical Symbols in a Drawing Sheet General Notes and/or Specifications. Electrical Layout. Schedule of Loads One Line Diagram Title Blockarrow_forwardThe term "____" is defined in NEC® Article 100 as "connected to establish electrical continuity and conductivity." Select one: A. BENDED (BENDING) B. BONDED (BONDING) C. SHUNTED (SHUNTING) D. GROUNDED (GROUNDING)arrow_forwardWhat assumptions can you make regarding the following receptacle wiring? Check all that apply. White neutral wire Grounding screw Brass screw terminal Silver screw terminal Black hot wire Red hot wire Grounding wires Grounding screw terminal O device is at end-of-run device box does not need a ground connection this is a split-circuit receptacle neutral side receptacle tab must be removedarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT