Assignment - The Hub Oil LI
.pdf
keyboard_arrow_up
School
University of Alberta *
*We aren’t endorsed by this school
Course
406
Subject
Industrial Engineering
Date
Feb 20, 2024
Type
Pages
35
Uploaded by MasterWorldGrasshopper21
12/15/23, 8:39 AM
Assignment - The Hub Oil LI - Graded: Attempt review
https://eclass.srv.ualberta.ca/mod/quiz/review.php?attempt=14143507&cmid=7288202
1/35
Started on
Tuesday, 14 November 2023, 10:54 AM
State
Finished
Completed on
Friday, 24 November 2023, 11:55 PM
Time taken
10 days 13 hours
Marks
47.54/64.00
Grade
74.27
out of 100.00
12/15/23, 8:39 AM
Assignment - The Hub Oil LI - Graded: Attempt review
https://eclass.srv.ualberta.ca/mod/quiz/review.php?attempt=14143507&cmid=7288202
2/35
Question 1
Correct
Mark 6.00 out of
6.00
Imagine if you will, a refinery had a small fire, but not catastrophic like those that make the global
headlines. A root cause analysis was done on this fire, of which one root from the "loss incident"
through to the latent cause. You have been assigned to match the actual cause from the root to the
category and sub-category as illustrated in this graphic:
(Note: The "match" choices in the question for the intermediate causes are denoted as "First Intermediate"
and "Second Intermediate" only to aid in your selection and scoring. There is no significance to the "First"
or "Second" except as it relates to the automatic scoring function on eClass quizzes.)
12/15/23, 8:39 AM
Assignment - The Hub Oil LI - Graded: Attempt review
https://eclass.srv.ualberta.ca/mod/quiz/review.php?attempt=14143507&cmid=7288202
3/35
Petrol released
from pump casing
resulting in a
petroleum fire
Pump casing
corroded (failed)
Casing material
was incompatible
Improper material
was used
Pump design was
incorrect
The refinery design
program did not
include a standard
to design pumps
for this process
service.
Incident description (abbreviated)
Immediate Cause: Sub-standard condition
Intermediate Cause
Intermediate Cause
Basic Cause: Engr&Design – inadequate technical design
Latent Cause - Inadequate Performance Standards: relates to RME#7 DC&SU
Your answer is correct.
12/15/23, 8:39 AM
Assignment - The Hub Oil LI - Graded: Attempt review
https://eclass.srv.ualberta.ca/mod/quiz/review.php?attempt=14143507&cmid=7288202
4/35
The correct answer is: Petrol released from pump casing resulting in a petroleum fire → Incident
description (abbreviated), Pump casing corroded (failed) → Immediate Cause: Sub-standard condition,
Casing material was incompatible → Intermediate Cause, Improper material was used → Intermediate
Cause, Pump design was incorrect → Basic Cause: Engr&Design – inadequate technical design, The
refinery design program did not include a standard to design pumps for this process service. → Latent
Cause - Inadequate Performance Standards: relates to RME#7 DC&SU
12/15/23, 8:39 AM
Assignment - The Hub Oil LI - Graded: Attempt review
https://eclass.srv.ualberta.ca/mod/quiz/review.php?attempt=14143507&cmid=7288202
5/35
Question 2
Correct
Mark 5.00 out of
5.00
Please recall the PEAP model of losses (People, Environment, Assets, Production). Match the following
with the correct PEAP category for the losses at The Hub Oil Loss Incident:
Two (2) fatalities, and six (6) people struck by shrapnel at the Hub Oil
Plant
Large noxious plume of black smoke over several days; volume of
hydrocarbons released through surface run-off.
Entire facility destroyed; loss of personal and company vehicles.
Facility permanently shut down - can no longer process used oil for
recycling at rate of 15 million litres per year.
Wide residential areas were evacuated, with exposure to potentially
harmful emissions.
People - Workers
Environment
Assets
Production
People - General Public
Your answer is correct.
People - Workers: Two (2) fatalities, and six (6) people struck by shrapnel at the Hub Oil Plant
People - General Public: Wide residential areas were evacuated, with exposure to potentially harmful
emissions.
Environment: Large noxious plume of black smoke over several days; volume of hydrocarbons released
through surface run-off.
Assets: Entire facility destroyed; loss of personal and company vehicles.
Production: Facility permanently shut down - can no longer process used oil for recycling at rate of 15
million litres per year.
Distractor: The light-rail commuter line running just north of the plant was temporarily shut-down as a
precautionary measure.
12/15/23, 8:39 AM
Assignment - The Hub Oil LI - Graded: Attempt review
https://eclass.srv.ualberta.ca/mod/quiz/review.php?attempt=14143507&cmid=7288202
6/35
The correct answer is: Two (2) fatalities, and six (6) people struck by shrapnel at the Hub Oil Plant →
People - Workers, Large noxious plume of black smoke over several days; volume of hydrocarbons
released through surface run-off. → Environment, Entire facility destroyed; loss of personal and
company vehicles. → Assets, Facility permanently shut down - can no longer process used oil for
recycling at rate of 15 million litres per year. → Production, Wide residential areas were evacuated, with
exposure to potentially harmful emissions. → People - General Public
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
- Access to all documents
- Unlimited textbook solutions
- 24/7 expert homework help