(a) What is the difference between precision and accuracy? (b) How can random errors be minimised when collecting experimental data? A strain gauge has a nominal resistance of 150 2 and a gauge factor of 2.5. It is used in a quarter bridge with other resistors, also with a nominal resistance of 150 2, and a 5 V supply voltage. (i) Determine the strain if the output voltage is 15 mV. (ii) State TWO possible sources of error with the strain measurement. (c) (d) Explain, with the aid of diagrams, the operation of two different pressure transducers, one which uses strain gauges and one which does not.

Functions and Change: A Modeling Approach to College Algebra (MindTap Course List)
6th Edition
ISBN:9781337111348
Author:Bruce Crauder, Benny Evans, Alan Noell
Publisher:Bruce Crauder, Benny Evans, Alan Noell
Chapter2: Graphical And Tabular Analysis
Section2.4: Solving Nonlinear Equations
Problem 6E: Altmans z-score Altmans z-score is a financial tool for predicting insolvency in a business. For a...
icon
Related questions
Question
(a)
What is the difference between precision and accuracy?
(b)
How can random errors be minimised when collecting experimental data?
A strain gauge has a nominal resistance of 150 2 and a gauge factor of 2.5. It is used in a
quarter bridge with other resistors, also with a nominal resistance of 150 2, and a 5 V
(c)
supply voltage.
(i) Determine the strain if the output voltage is 15 mV.
(ii) State TWO possible sources of error with the strain measurement.
Explain, with the aid of diagrams, the operation of two different pressure transducers, one
which uses strain gauges and one which does not.
(d)
Transcribed Image Text:(a) What is the difference between precision and accuracy? (b) How can random errors be minimised when collecting experimental data? A strain gauge has a nominal resistance of 150 2 and a gauge factor of 2.5. It is used in a quarter bridge with other resistors, also with a nominal resistance of 150 2, and a 5 V (c) supply voltage. (i) Determine the strain if the output voltage is 15 mV. (ii) State TWO possible sources of error with the strain measurement. Explain, with the aid of diagrams, the operation of two different pressure transducers, one which uses strain gauges and one which does not. (d)
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Functions and Change: A Modeling Approach to Coll…
Functions and Change: A Modeling Approach to Coll…
Algebra
ISBN:
9781337111348
Author:
Bruce Crauder, Benny Evans, Alan Noell
Publisher:
Cengage Learning
Algebra & Trigonometry with Analytic Geometry
Algebra & Trigonometry with Analytic Geometry
Algebra
ISBN:
9781133382119
Author:
Swokowski
Publisher:
Cengage
College Algebra
College Algebra
Algebra
ISBN:
9781938168383
Author:
Jay Abramson
Publisher:
OpenStax
Trigonometry (MindTap Course List)
Trigonometry (MindTap Course List)
Trigonometry
ISBN:
9781337278461
Author:
Ron Larson
Publisher:
Cengage Learning