Course Contents » ... » Timer Notes Evaluate Feedback Print Inf 3. What type of laboratory glassware is used when the accuracy and precision of volume is critical to quantitative analysis? Enter the one word term, using lower case letters, that represents this type of glassware. Submit Ancwer Tries 0/99
Q: Which sentence is false about gravimetric analysis? a. It is used for inorganic b. It is used to…
A: The statement which is false about gravimetric analysis is, Relative precision 3% to 4%
Q: What is a rotameter? An orifice meter?
A: Rotameter - It is a form of variable area flow meter, used to measure the volumetric flow rate of…
Q: Why would precision not matter when you are calibrating a pipette? Background info: You are counting…
A: Titration is the quantitative method of estimating the strength of the any component. Molarity is…
Q: Answer the questions using one of the words or phrases from the following list. We suggest that you…
A: Accuracy -In a set of data or measurements accuracy is measurement of how close the data is from its…
Q: A 5.00 (+0.01) ml Class A transfer pipet is used to transfer 5.00 mL of a 0.309 (20.003) M Cut stock…
A: In order to determine the concentration of the diluted solution, apply the dilution formula:…
Q: what is the biggest buret size that'll deliver 4.8mL with a relative error less than or equal to…
A: Answer - According to the question - Given - volume need to be delivered is 4.8 mL with an accuracy…
Q: The data system; controls all modules of the HPLC instrument; takes signal from the detector and…
A: Ans: Computer
Q: What information should the INTRODUCTION section of a chemistry lab report contain? Select all that…
A: Given : What information should the introduction section of a chemistry lab report contain ?
Q: accuracy of the following instruments: a. analytical balance b. top-loading balance c. serological…
A: Since you have posted a question with multiple sub-parts, we will solve first three sub-parts for…
Q: 2. Propose three types of procedural error that may impact the results that were experimentally…
A: Answer. Errors generally occur while conducting experiments which can effect our results but with…
Q: Give other 5 examples of laboratory task stating its potential hazard and recommended PPE.
A: Five examples of laboratory hazards, 1. Fire/Explosions In a research facility, all synthetic…
Q: Matching Type Force a liquid (mobile phase) through the liquid chromatograph at a specific flow rate…
A: Forces a liquid (mobile phase) through the liquid chromatograph at a specific flow rate = Pump…
Q: Write a 2-3 paragraph summary on an advanced material. Make sure to Include the following: 1)…
A: Advanced materials are specially designed to show new or improved properties that represent a higher…
Q: David is in dilemma to choose a suitable chromatographic detector for gas chromatography analysis.…
A: The detector which detects the pesticide content in vegetables has to be given and the two…
Q: What part fo chromatography is being descibe by the following?…
A: These all are the terms used in the chromatography.
Q: Thereproducibility of replicate measurements may be expressed by: 1. ORelative error 2. OAbsolute…
A: A multiple choice question based on statistical analysis, which is to be accomplished.
Q: Vitamin C Analysis, a student accidentally puts 1.0 g of sodium bicarbonate (NaHCO3) solid into the…
A: The sodium bicarbonate (NaHCO3) solid is a base which neutralises the acid in the reaction. Hence it…
Q: be micro a
A: Electron probe microanalyzer is an analytical tool used to determine the chemical composition of…
Q: . Describe volumetric quantitative analytical methods.
A: In chemistry, there are many ways to check the deviation of experimental data from the accurate…
Q: Sample Blank $2 $3 $4 $5 $6 $7 $8 $9 $10 Stock of Fe Stock of SC Volume Fe3+, mL 2.000 2.000 2.000…
A: From the given data we have Concentration of [FeNCS2+]=[SCN-] Basing on the given chart we have to…
Q: Match the given parts with the correct function integrator A. holds as the mobile phase detector B.…
A: In the given question, functions of several units of a standard hplc system are clearly discussed.
Q: High-pressure ATR is used to analyze very hard sample. True False
A: Attenuated total reflection (ATR) spectroscopy is an analysis technique that utilizes the surface of…
Q: nL of the unknown were pipetted into each of five 50.0-ml volumetric flasks. Various volumes of a…
A:
Q: What are the mandatory components required for column Chromatography? Please shortly answer at your…
A: Columns chromatography is used for separation of mixtures By using stationary and mobile Phase.
Q: C. Standardization Weight of vial and KHPH 59.09 Weight after 1st transfer 58.2 Weight after 2nd…
A: Given data,Mass of KHPh in flask 1=0.8gMass of KHPh in flask 2=1.7gMass of KHPh in flask…
Q: The labware we used in Quant Lab is divided into “qualitative” or “quantitative” analytical purpose.…
A: The glassware used in the lab are divided into 2 types that is qualitative and quantitative. As it…
Q: I got a task in analytical chemistry to calibrate, standardize, verify and validate an analytical…
A: It is said that every location in the world is positioned differently in relation to magnetic…
Q: Calculate the standard deviation and % error using the following data table if the theoretical…
A:
Q: What is density, types of densities properties of a material, and suitable technique that can be…
A: Mass, volume, density etc. are the physical properties of a matter.
Q: During the course of an analysis for a solid sample, a loss of 0.40 mg occurs. Calculate the…
A: Relative error is defined as the ratio of absolute error to the true value. Here, Absolute error =…
Q: integrator A. measures absorbance data detector B. processes data into the display unit injection…
A:
Q: A balance high readability is necessarily equated to high accuracy. Select one: a. True b. False…
A:
Q: 6. Explain the instrumentation of super critical fluid chromatography in detail. You can construct a…
A: Super critical fluid chromatography -…
Q: QUESTION 8 Were the sample prep and the standard prep supplemented with the same amount of internal…
A: An internal standard in analytical chemistry is the substance similar to the unknown sample that is…
Q: A new method is proposed to simultaneously detectand separatefour foodadditives by reversed-phase…
A: (a) The mathematical expression for calculating the number of plates is: N=16(tRW)2
Q: Desk Name Date Lahoratory Instructor Unknown nn, or letter EXPERIMENT REPORT SHEET Gravimetric…
A:
Q: Use the data presented in Figure 2 as basis for your answer. The TLC plate used is 5 cm by 10 cm.…
A: According to the given TLC plate, Commercial analgesic dot A, show two signals at 1.5 cm and 3.9…
Q: Determine the relationship between the observed/apparent value (EX) VERSUS that of the true value…
A: Determine the relationship between the observed/apparent value (EX) VERSUS that of the true value…
Q: Retention time is the time taken for the mobile phase to reach the detector. True False
A: Answer - The above statement is false Explanation - Retention time - Retention time is the sum of…
Q: Write a 2-3 paragraph summary on an advanced material. Make sure to include the following: 1)…
A: Advanced materials are specially engineered to exhibit novel or enhance properties that portray…
Q: Rate dr Reatin tab mg + Itch toble 1: volume of gos produced In 3 cm strip mgt 5o-o ML ItCL gus, O…
A: In the reaction between magnesium and hydrochloric acid, the salt magnesium chloride is produced…
Q: for 20 minutes. Then return, put it down, and weigh yourself immediately three times. Since…
A: Quantitative Analysis: It deals with the determination of how much of one or more component is…
Q: DO R O a blackboard.uob.edu.bh View Assessment Given below is the diagram of Process of…
A: The unmarked component is detector. It is placed at the bottom of the column. It responds to solute…
Q: f the dwell time is 3.5 min for a solvent gradient of 5% B to to 60% B over 20 mi what is the % B…
A: Solution- Given data- Dwell time is 3.5 min. Solvent gradient of 5% B to 60% B in 20 min. To find-…
Q: In analytical instrument the stimulus can be digitizer or plotter. O True O False
A: In analytical instrument the stimulus can be digitzer or plotter. We have to say wheather the…
Q: A student accidentally started the chromatographic run without covering the beaker with a lid. Which…
A:
Q: A 0.500g sample is analyzed spectrophotometrically for manganese by dissolving it in acid and…
A: Given the mass of impure manganese(Mn) sample = 0.500 g 1st dilution: First, the solution was…
Q: b) Name four types of gas chromatograph (GC) column.
A:
Q: Standardization of EDTA Solution Weight of pure CaCO3: 0.2514 g % Purity of CaCO3: 98.0% Total…
A: Molarity of a solution is defined as the number of moles of solute present in one litre of a…
Trending now
This is a popular solution!
Step by step
Solved in 2 steps
- Can you please fill the rest of tghe data based on the on inforamtion you have and answer Average percent by mass of acetic acid in vinegar sample (%) ________________ Standard deviation of percent by mass of acetic acid in vinegar sample (%)I have struggled to get the answer. A classmate said it was 159, though I would like to see the steps in demensional analysis, with correct sig figs. thank you! Provide only typed solution answer no handwritten solution neededDetermine the relationship between the observed/apparent value (EX) VERSUS that of the true value (ET) for the quantity being sought by writing either <, >, or = on the space provided Determination of the true concentration (ppm Fe) in a water sample using the iron-phenanthroline method. Dilution factor was not taken into account. EX _____ 1ET
- Sources of Error Determine the relationship between the observed/apparent value (EX) VERSUS that of the true value (ET) for the quantity being sought by writing either <, >, or = on the space provided TOPIC: Determination of % SO32-Not all solid was transferred during the filtration of the precipitate. EX _____ ETa- Separation is essential in chemical analysis especially when we are dealing with complexmixture of chemical species. Name 1 separation technique based on basis of operation asbelow. Basis of operation Techniquei) Sizeii) Mass and densityiii) Change in physical stateYou are developing a Ca detection method for a graphite furnace AA instrument. Your analysis of ten blank samples gives a standard deviation of 0.265 ppb. To establish your limit of detection (LOD), what concentration of Ca should be spiked into your blanks?
- For Indirect Iodometric Analysis of Copper... ~0.0896g KIO3 necessary to consume 350mL of 0.1 M Na2S2O3, Na2S2O3 is stored in an amber glass bottle until ready for use. Primary Standard KIO3 has 2g of KI, 50mL of DI water, and 10 mL of 1.0M HCl is added then immediately titrated with Na2S2O3 until medium yellow or straw... then 5mL of starch indicator is added and titrated again until blue black color turns clear. Unknown CuO use 1.2G of Unknown, 20mL of HNO3 heated until sample dissolved, 25 mL of DI water added and boiled until clear light blue color, after cooling 1:1 NH3 added (~34.47 mL of NH4OH reagent) until permanent deep blue color amine complex, 2g of NH4HF2 added and swirled until dissolved, 3 g of KI is added then titrated immediately with Na2S2O3 until brown color of iodide is nearly gone (brown milk color), 2 g of KSCN and 3 mL of starch indicator is then added with titration continuing until disappearance of new blue black color. 1. Na2CO3 is often added to thiosulfate…For Indirect Iodometric Analysis of Copper... ~0.0896g KIO3 necessary to consume 350mL of 0.1 M Na2S2O3, Na2S2O3 is stored in an amber glass bottle until ready for use. Primary Standard KIO3 has 2g of KI, 50mL of DI water, and 10 mL of 1.0M HCl is added then immediately titrated with Na2S2O3 until medium yellow or straw... then 5mL of starch indicator is added and titrated again until blue black color turns clear. Unknown CuO use 1.2G of Unknown, 20mL of HNO3 heated until sample dissolved, 25 mL of DI water added and boiled until clear light blue color, after cooling 1:1 NH3 added (~34.47 mL of NH4OH reagent) until permanent deep blue color amine complex, 2g of NH4HF2 added and swirled until dissolved, 3 g of KI is added then titrated immediately with Na2S2O3 until brown color of iodide is nearly gone (brown milk color), 2 g of KSCN and 3 mL of starch indicator is then added with titration continuing until disappearance of new blue black color. 4. Why is the starch indicator solution…An analyst determines the Cl^- content of rain water with ion chromatography. The data for the calibration line in the range 5 to 50 milli equivalents per liter (mEq/L) is shown in the table below. Additionally, a blank sample was analysed 5 times and the following results obtained: 1.1, 0.5, 0.1, 0.9 and 1.2 ppm Ct Calculate the detection limit (DL) for the method with a 98.3% confidence level. Use ALL data and show equations