Q: Shew cenplele selutions for cach of the preblee. Fr the analyris of unknown seda and vineger…
A: KHP or potassium hydrogen phthalate is used for the standardization of NaOH solution. The reaction…
Q: If you have a sample which has an absorbance of 1.17, a molar absorptivity of 1 Mcm1, and a cuvette…
A: The given data contains, Absorbance=1.17path length=1.15 cmMolar absorptivity=1 M-1.cm-1
Q: PART B. Spectrophotometrilc Determination of the Copper Content of a Penny Mass of penny:3.138 Date…
A:
Q: Which of the following detector NOT consider as solute property? O a. Conductivity О а. Ob. O b.…
A:
Q: A) Given the following set of data, plot the chromatogram (absorbance versus volume of eluate). Vol…
A: To plot the chromatogram, the volume of eluate is taken as x axis and absorbance as y axis The graph…
Q: Draw Fragment m/z of 87 Draw Fragment m/z of 73
A: Fragmentation occurs when a molecule passes through a ionization chamber of a mass spectrometer it…
Q: concentration
A:
Q: 12. This detector is not used in HPLC: a) ECD b) MS c) Fluorescence d) RI
A: Mixture components are estimated using HPLC detectors. The actual separation in HPLC (High…
Q: confirmation ▪ True or false: The purpose of the internal standard is to make quantitation of the…
A: Internal standard is added blank as well as sample to determine the concentration of analyte.
Q: Mechanism of separation is adsorption. ONPLC O IEX HILIC SEC
A:
Q: Find the weight factor of iodide I in, Hg(IO2)
A: The amount of quantity of matter present in the substance is explained by the term mass. It is…
Q: spot of black ink was placed on a strip of filter paper. The chromatogram was developed using an…
A:
Q: How many hours are required to plate a 0.01 mm thick layer of Cr on an object whose area is 200 cm2…
A:
Q: D X F C E F Figure 1. Paper Chromatogram Pigments X F E Rf Values 0.15 0.32 --
A: C is called TLC plate or Thin Layer Chromatography plate.
Q: [A] [B] rate trial M/s 1. 0.827 0.647 0.048 0.442 0.976 2.
A: Welcome to bartleby !
Q: High-pressure ATR is used to analyze very hard sample. True False
A: Attenuated total reflection (ATR) spectroscopy is an analysis technique that utilizes the surface of…
Q: 2. Usé thè linear regression équation ànd the fóllowing Abs 595 dată and dilution factors för…
A:
Q: 10. which of the followings is the universal detector used in IHPLC: a) Fluorescence b) IR c) FID d)…
A: HPLC ("High-Performance Liquid Column") is utilized to separate and distinguish the components that…
Q: a. Calculate the base saturation using the following given miliequivalent weights obtained from a…
A: answer - a) given data are - 25 gm of soil, a. Ca++= 2.23 m.e.; b. Mg++=1.32 m.e.; c. Na+= 1.98…
Q: ncentration of 3 X 10 M. Find the time required to convert 70% of substrate when Vmax = 2.167 M/min.…
A:
Q: alpha source was counted for 10 hours at a distance of 2 cm from a detector with an active face area…
A:
Q: How resolution in HPLC analysis can be improved?
A: HPLC i.e high-performance liquid chromatography is an analytical method which is being used to…
Q: जिोट मेट (णणेर केनंजलवेकळ +क्स गनण following.Cma • raw with farmal charge प्केक किoजकव tode ero on…
A:
Q: 5.) The literature value for the Ksp of lead(II) chromate is 2.8 x 10 13. Calculate the percent…
A:
Q: ) -SH -OCH₂ -NO₂ silica column 20% CHCI₂ 6 Time (min) 8 -CIN 10 -OH -CO₂CH₂-COCH, CHO 12 -NH₂ 400…
A: Silica Column is eluted by 29% CHCl3. Now in the given graph elution time of different compounds are…
Q: Draw Fragment with m/z of 87 + Draw Fragment m/z of 45
A: Alpha cleavage of alcohol. Path 1 : It gives fragment m/z of 45
Q: sputreometrey ? pieobable fragmentadion patteen 1 [o (co)3 ( NO) what melas fable plale in mau eaues…
A: mass spectrometry
Q: Q6. The key difference between bottom-up and top- down synthesis methods is: O Thickness O Size…
A: The Top-down approach involves the breaking down of bulk material into Nano sized structures or…
Q: Calculate retention time for (D, E, F, G) Calculate K, Ka Calculate (AB) Selectivity Calculate…
A:
Q: List the desirable characteristics of HPLC detectors.
A:
Q: Derivatiztion of sample is carried out to: a) Improve analyte peak shape analyte resolution b)…
A: Derivatization of sample is carried out to, (a) Improve analyte peak shape (b) Increase the detector…
Q: Given the following spectrophotometric data, what is the most appropriate linear equation to use?…
A: It is an application of Lambert Beer law
Q: Column A Cesponse Unretained peaks Compound Y Compound X Time (min) 8 min. Compound Y Column B…
A: We can decide the effectiveness of resolution in column chromatography based on the nature of the…
Q: 8. Derivatiztion of sample is carried out to: a) Improve analyte peak shape analyte resolution b)…
A: “Since you have asked multiple question, we will solve the first question for you. If you want any…
Q: which of the followings is the universal detector used in HPLC: a) Fluorescence b) IR c) FID d) ECD…
A: The universal detector used in HPLC has to be given.
Q: Question attached
A: Chromatography is a technique that is used to separate components of mixture.
Q: An atomic absorption method for the determination of the amount of iron present in used jet engine…
A: Solutions- a standard deviation s = 3.1 µg Fe/mL. calculate the 95 and 99% confidence intervals…
Q: or non provid- a) PCI- c) OF
A: This question is related to Lewis structure.
Q: laq letm 2. What error would be introduced into the determination of the density of the irregularly…
A: Given : irregular shaped metal pellets. To find : effect on the density of the metals. Solution :…
Q: List three typical examples applications of SFC analysis.
A: SFC analysis refers to Supercritical fluid chromatography analysis. It is an analytical method that…
Q: Does CI aroms have an isotopic pattern of 1:1 relative intensity of M and M+2. True or False?
A:
Q: Analytes than can be trapped inside Sephadex G-25 (1,000-5000) Cytochrome C (MW=12384) Aprotinin…
A: Sephadex is a bead-formed gel prepared by cross linking dextran with epichlorohydrin. It is supplied…
Q: A quality control (QC) sample was run in replicates of six to produce the following concentrations…
A: Answer to ist question: 3.3% Yes
Q: а. H 100 - Compound 80 - H- Fragment 60 40- 20 10 20 30 40 50 60 70 80 m/z 100 - Compound af on 80 -…
A: The assignment of base peak in a mass spectrum totally depends on the stability of the species…
Q: which of the folowing(s) is/are true ? 1 split ratio in GC is a ratio of sample passed to column…
A: Column resolution increases with increase in length and decrease in diameter.
Q: In TLC, point of origin refers to O The bhottom edge of the TLC plnto.
A: Question 1: Option 1 is the correct answer. The point of origin was sketched very lightly with…
Q: UVVIS spectrophotometry
A: Correct: A
Q: explain the differences between NH4-N and TKN methods.
A: The differences between NH4-N and TKN method have to be explained below.
Answer
The given sloppy separation of PbSO4 is determined by electrochemical series only one metal Zn+2 ion can separate, Zn+2 ion has high reduction potential than Pb+2
Step by step
Solved in 2 steps
- The buret was filled with 0.100 M HCl solution. Then was transferred in a 25.0 mL of saturated calcium hydroxide solution (2g of calcium hydroxide per 100 ml of water) in two separate E-flasks. Then 2 drops of phenolphthalein was added to each flask Titration data for the determination of the common ion effect: Trial 1: Final Buret reading (ml)-29.50; Initial Buret reading (ml)- 26.10; Temperature (Celcius)- 25 Trial 2: Final Buret reading (ml)-33.30; Initial Buret reading (ml)- 29.50; Temperature (Celcius)- 25 Voume of HCl used: Trial 1- 3.40ml; Trial 2- 3.80mL. Report in proper sigfigs. 1. Compute for the moles of H+ used and the moles of OH- present. moles of H+ used = (concentration of HCl) × (volume of HCl used)moles of OH- = moles of H+ used 2. Use the dilution formula to determine the initial concentration of the common ion. C1V1 = C2V2 3. Construct an ICE table for the reaction.4. Calculate the molar solubility…The buret was filled with 0.100 M HCl solution. Then was transferred in a 25.0 mL of saturated calcium hydroxide solution (2g of calcium hydroxide per 100 ml of water) in two separate E-flasks. Then 2 drops of phenolphthalein was added to each flask Titration data for the determination of the common ion effect: Trial 2: Final Buret reading (ml)-33.30; Initial Buret reading (ml)- 29.50; Temperature (Celcius)- 25 Voume of HCl used: Trial 2- 3.80mL. Report in proper sigfigs. 1. Compute for the moles of H+ used and the moles of OH- present. moles of H+ used = (concentration of HCl) × (volume of HCl used)moles of OH- = moles of H+ used 2. Use the dilution formula to determine the initial concentration of the common ion. C1V1 = C2V2 3. Construct an ICE table for the reaction.4. Calculate the molar solubility (in mol/L) of OH- and Ca2+.5. Determine the solubility of Ca(OH)2 in g/L. (MM of Ca(OH)2 = 74.096 g/mol).…The buret was filled with 0.100 M HCl solution. Then was transferred in a 25.0 mL of saturated calcium hydroxide solution (2g of calcium hydroxide per 100 ml of water) in two separate E-flasks. Then 2 drops of phenolphthalein was added to each flask Titration data for the determination of the common ion effect: Trial 2: Final Buret reading (ml)-33.30; Initial Buret reading (ml)- 29.50; Temperature (Celcius)- 25 Voume of HCl used: Trial 2- 3.80mL. Report in proper sigfigs. 1. Calculate the molar solubility (in mol/L) of OH- and Ca2+.2. Determine the solubility of Ca(OH)2 in g/L. (MM of Ca(OH)2 = 74.096 g/mol). 3. Calculate the Ksp of Ca(OH)2. Make sure to include the effect of the common ion in the calculation.
- An analyte has an Rf value of 0. 75 What does that indicate about the solubility of the analyte in the mobile phase as compared to the stationary phase?An analyte has a Rf value of 1. What does that say about the solubility of the analyte in the mobile phase as compared to the stationary phase? (please show me all steps)A 100 ml bottle of metronidazole 100 mg/ml suspension is available in your pharmacy. Calculate the volume of this suspension needed to be diluted with cherry syrup to prepare 60 ml of a 4% metronidazole suspension. 1 ml of a 1:1000 epinephrine injection was mixed with 20 ml of 1% lidocaine injection. Calculate the new ratio strength of epinephrine in the admixture. (IGNORE ANY VOLUME CHANGES AFTER ADMIXTURE) Instead of preparing 4 grams of tetracaine hydrochloride 4% gel an 8% gel was compounded by mistake. How many grams of the 8% gel and gel base must be mixed to get 4 grams of a 4% gel? How many milliliters of 70% ethanol and 20% ethanol must be mixed to prepare 500 ml of 30% ethanol? A diphenhydramine elixir contains 12.5 mg drug in one teaspoon. The volume of oral vehicle that is to be added to 100 ml of this elixir to reduce its strength by one half its original strength is; 6. 90 capsules of Liothyronine (T3) 15 micrograms are to be prepared. The formula calls for a 1:10000…
- How would your calculation of the Molarity of KMnO4 have been affected (Higher, Lower, No Change) if . . . you recorded the endpoint volume and then noticed that the color had faded . . . . you did not add more KMnO4 solution? you were unable to complete the 3rd Trial and stored your KMnO4 solution in your desk for 3 days before completing the 3rd titration with the stored solution? you had added twice as much sulfuric acid as was called for in the procedure?All of the following will generate reproducible but not accurate results except a. The analytical balance is not calibrated. b. The sample was not stirred well before getting aliquot for analysis. c. A blank was not used in calculation of concentration in a colorimetry experiment. d. The correction for quality of glass in pH probe is not included in calculation of pH.Which of the following is not a component of the mobile phase in Ion exchange chromatography a. buffer b. organic solvents c. counter ions d. none of the chouices
- What conclusion can be derived from the following sentences regarding analytical methods: I. Classical methods (gravimetry and volumetric methods) are no longer useful in analytical chemistry. II. Volumetric methods do not require calibration if a primary standard is used as titrant. III. Instrumental methods are useful with analyte solutions that are less than 1.00 mM. IV. Classical methods yield high precision and accuracy at concentrations greater than 1.00 mM. What conclusion can be derived from the following sentences regarding analytical methods: Two statements are incorrect. All statements are correct. One statement is incorrect. Only one statement is correct. All statements are incorrect.All of the following criteria must be met for a titrimetric analysis to be feasible EXCEPT: Select one: a. Reaction between the standard and analyte must be known. b. There should be a substance for endpoint detection c. Reaction must proceed quantitatively to completion. d. Reaction between the reactants must be slow.1. These are balances that have a maximum loading of 10 to 30 g with a precision of 60.01 mgA. semi-microanalyticalB. MicroanalyticalC. MacrobalancesD. Triple Beam Balance2. Which type of curve is normally produced when plotting the change in the concentration of a specie of some function and the amount of reagent added?A. Titration curveB. Sigmoidal CurveC. Phase Transition curveD. Calibration curve3. In the dead dear case study, silver diethyldithiocarbamateforms a colored solution when it binds with arsenic, what do we call substance like silver diethyldithiocarbamate?A. Secondary standard reagentB. Precipitating agentC. Chelating agentD. Primary standard reagent