Electrochemical detection is commonly used in combination capillary electrophoresis systems. This is a type of hydrodynamic voltammetry called flow injection, where it has been shown that ilim a U1/3, where U is the flow rate of the solution. Flow analysis of a urine sample at a thin-layer amperometric detector, with a flow-rate of 1.25mL/min, yielded a limiting current value of 1.6µA for its unknown uric acid content. A larger current of 2.4µA was observed for a sample containing 1 × 10-4 M uric acid and flowing at a rate of 0.9mL/min. Calculate the original concentration of uric acid in the sample

Principles of Instrumental Analysis
7th Edition
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Chapter25: Voltammetry
Section: Chapter Questions
Problem 25.11QAP
icon
Related questions
Question
Electrochemical detection is commonly used in combination capillary electrophoresis systems.
This is a type of hydrodynamic voltammetry called flow injection, where it has been shown that
ilim a U1/3, where U is the flow rate of the solution.
Flow analysis of a urine sample at a thin-layer amperometric detector, with a flow-rate of
1.25mL/min, yielded a limiting current value of 1.6µA for its unknown uric acid content. A
larger current of 2.4µA was observed for a sample containing 1 × 10-4 M uric acid and flowing
at a rate of 0.9mL/min. Calculate the original concentration of uric acid in the sample
Transcribed Image Text:Electrochemical detection is commonly used in combination capillary electrophoresis systems. This is a type of hydrodynamic voltammetry called flow injection, where it has been shown that ilim a U1/3, where U is the flow rate of the solution. Flow analysis of a urine sample at a thin-layer amperometric detector, with a flow-rate of 1.25mL/min, yielded a limiting current value of 1.6µA for its unknown uric acid content. A larger current of 2.4µA was observed for a sample containing 1 × 10-4 M uric acid and flowing at a rate of 0.9mL/min. Calculate the original concentration of uric acid in the sample
Expert Solution
steps

Step by step

Solved in 2 steps with 9 images

Blurred answer
Knowledge Booster
Electroanalytical Techniques
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning