short shunt compound generator with Ra = 0.05 ohms, Rse = 0.3 ohms, and Rsh = 200 ohms delivers a load current of 30 A; VT=220V . Calculate the induced emf, as well as Ia. As a contact drop, allow 1.0 per brush. (Draw the circuit
Q: Some test have been made on a 250 kVA, 800 V, 50 Hz three-phase star connected synchronous generator…
A: An alternator/Synchronous generator is a type of electrical machine that converts mechanical energy…
Q: A short-shunt compound generator delivers a load current of 30 A at 220 V, and has armature,…
A:
Q: 3-phase, 9 kVa power, 60hz, 208 Volt 8-pole synchronous generator, winding resistance is negligible,…
A: Given in the question: Ratings: 3 phase, 9KVA, 208V, 60Hz Power factor = cosϕ=0.8 (A): The terminal…
Q: A two-pole Y-connected synchronous generator has a voltage level of 2300 V, a capacity of 1000 kVA,…
A: Given P=2 V=2300 V S=1000 kVA pf=0.8 lagging Ra=0.15 Ω Xa=1.1 Ω f=50 Hz PFW=24 kW Pcore=18 kW
Q: A 3-phase, 2000 kVA, 11 kV, 1800 rpm synchronous generator has a resistance of synchronous reactance…
A:
Q: A3-phase, F--connected, 2-pole alternator nuns at 3,600 rp.m. If there are 500 conductors per phase…
A: 3ϕ,Y = 2 pole . #600 rpm , 500 conductors/phase ϕ = 0.1 , f= ? , Emf/phase = ? Ns = 120fPf= NsxP120…
Q: Example 3 A short-shunt compound generator delivers a load current of 30 A at 220 V. It has…
A: This question belongs to electrical machine . It is based on the concept of generated e.m.f. in a…
Q: A long shunt compound generator with Ra = 0.05 ohms, Rse = 0.3 ohms, and Rsh = 200 ohms delivers a…
A:
Q: A long shunt generator delivers 25kW at 220V. The shunt, series and armature resistances are 50Ω,…
A:
Q: approximate equivalent (type L) circuit parameters; There is a 3 phase, star connected, 50 Hz…
A: Given information about a three phase,bipolar,squirrel cage induction motor operated from 50 Hz…
Q: Example 34.6. A 3-6 induction motor having a star-connected rotor has an induced e.m.f. of 80 volts…
A: INDUCTION MOTOR: Based on the rotor construction, the induction motor is classified into Squirrel…
Q: A long shunt compound generator is rated 22 kW at 220 V. Its armature, series field, and shunt field…
A:
Q: Discuss the application of the following Flexible AC Transmission Systems (FACTS) devices: a)Shunt…
A: In this question we discuss the application of shunt and series compensator.
Q: Find the turns ratio of three single-phase transformers connected to form a three-phase system with…
A:
Q: 4. Determine the voltage regulation of a 2,000-V, 1-phase alternator giving a current of 100 A at…
A:
Q: A 4 pole wave wound shunt generator delivers 195A at a terminal voltage of 205V. Ra and Rsh are…
A: Given data : P= 4VL=205 VIL=195ARsh=70 ΩRa=0.05 Ω
Q: The synchronous reactance of a 500V, 50 kVA alternator having an effective resistance of 0.2 52 if…
A: Given: Armature current on short circuit, Isc=200 A An emf on open circuit, Voc=450 V
Q: A 8 pole wave wound shunt generator delivers 205A at a terminal voltage of 200V. Ra and Rsh are…
A: Disclaimer: Since you have asked multipart questions, we will solve the first three subpart for…
Q: A 200 MVA, 25 kV, cylindrical rotor, synchronous generator has a saturated synchronous reactance of…
A: Here synchronous generator with 200 MVA and Vt =25kV is given. And synchronous reactance is given…
Q: A 3 phase star connected alternator is rated at 1600 kVA, 13,500 V. The armature effective…
A: It is given that: PL=1280 KW=1280×103 WS=1600 KVA=1600×103 VAVL=13500 V Ra=1.5 ΩXc=30 Ω
Q: A 50 kVA, 550 volt single phase alternator draws a field current 10A at rated load with the same…
A:
Q: A 10 pole wave wound shunt generator delivers 200A at a terminal voltage of 245V. Ra and Rsh are…
A: Armature current =load current +shunt field current. Current per parallel path = total armature…
Q: Example 34.6. A 3-6 induction motor having a star-connected rotor has an induced e.m.f. of 80 volts…
A: Given: A 3-6 induction motor having star connected rotor.
Q: A 3-phase, 200 MVA, 44 kV, 50 Hz synchronous generator is operating under no load and excited to…
A: Given, Power rating of the synchronous generrator= 200 MVAVoltage rating of the ynchronous…
Q: Q1 (a) A 3 phase induction motor operating at rated power can be represented by a balanced delta…
A: Since we only answer up to 3 sub-parts, we’ll answer the first 3. Please resubmit the question and…
Q: A three-phase star-connected alternator is rated at 1750 KVA, 13.8 KV, The armature resistance and…
A:
Q: A 15kVA, 440V, single-phase alternator draws a field current of 5A at rated load. With the same…
A:
Q: The effective armature resistance of a 3-phase, star connected, 500 kVA, 1100 V alternator is 0.1 £…
A:
Q: Homework problem: The per-phase equivalent circuit parameters of 33 kW, 60 Hz, star-connected, 4…
A: In this question we will find synchronous speed , slip, input current and power factor ,input power…
Q: single-phase alternator resistance of 0.20 ohm. A field resistance of 10A produces an armature…
A:
Q: Q) A P-Pole three-phase induction machine with spatial distribution of stator windings is assumed to…
A: We will find that the , two cycles of emf is produced in one complete revolution of conductor.…
Q: A 1500-kVA, 6.6 kV, three-phase, star-connected synchronous generator has a resistance of 0.5…
A: Given: A 1500-kVA, 6.6 kV, three-phase, a star-connected synchronous generator has a resistance of…
Q: A 50 kVA, 500 V, single phase alternator gives 700 V on open circuit at the field current of 15 A.…
A:
Q: A three-phase synchronous generator is driven by a gas turbine. The synchronous reactance is X=4 2.…
A: Since you have posted a question with multiple sub-parts, we will solve the first three sub-parts…
Q: Define derating, why must a 60Hz generator be derated if it is to be operated at 50Hz? Find…
A: sol: Derating means it is a technique used to operate devices at less than their rated maximum…
Q: A 5 MVA phase, 14.1-KV, 0.85-PF-lagging, 50Hz, 4-pole, Y-connected steam-turbine generator has a…
A: This question is from "Synchronous Machine". Under which we are going to study "synchronous…
Q: The open circuit and short circuit data of a three-phase, 3300 V, 500 kVA, star connected alternator…
A:
Q: Some test have been made on a 250 kVA, 800 V, 50 Hz three-phase star connected synchronous generator…
A:
Q: 380 V, 50 Hz, 2p = 6, star connected induction motor impedance in ohms per phase values: R1 = 0.3,…
A: Note : We are authorized to answer three subparts at a time, since you have not mentioned which part…
Q: A high voltage 3 phase induction motor operating at rated power can be represented by a balanced…
A: You have asked multiple independent questions. We are authorized to answer one question at a time.…
Q: A 5 MVA, 3-phase, 14.1-KV, 0.85-PF-lagging, 50-Hz, 4-pole, Y-connected steam-turbine generator has a…
A:
Q: A 3-phase, 2000 kVA, 11 kV, 1800 rpm synchronous generator has a resistance of synchronous reactance…
A:
Q: An 11-kV, three-phase wye-connected generator has a synchronous impedance of 6-ohms per phase and…
A: At maximum power condition angle between open circuit voltage and terminal voltage is 90 degrees.…
Q: A single phase autosequential CFI is fed from a 220 Vde source, R_{L} = 10Omega the thyristor turn…
A:
Q: A Short shunt compound generator delivers a load current of 47 A at 244 V, and has the armature,…
A: Find the generated voltage of the short compound generator. Short shunt compound generator, shunt…
Q: 3 phase 5 kVA, 200V, 50Hz, star connected, 2 pole (2p = 2) round rotor synchronous machine has 1.5Ω…
A: Here synchronous generator is given and we have to first draw equivalent circuit and then find the…
Q: H.W Q1) A four pole, three-phase synchronous generator is rated 250 MVA, its term is 24 kV, the…
A: Armature winding leakage reactance and a reactance used to depict armature reaction are combined to…
Q: With aid of diagram, derive and proof that the internal generated voltage of a synchronous generator…
A: Synchronous generator- A machine which works on the principle of electromagnetic induction and gives…
Q: A 6 pole wave wound shunt generator delivers 180A at a terminal voltage of 215V. Ra and Rsh are…
A:
A short shunt compound generator with Ra = 0.05 ohms, Rse = 0.3 ohms, and Rsh = 200 ohms delivers a load current of 30 A; VT=220V . Calculate the induced emf, as well as Ia. As a contact drop, allow 1.0 per brush. (Draw the circuit diagram)
Step by step
Solved in 3 steps with 2 images
- A single-phase alternator connected to 6,600-V bus-bars has a synchronous impedance of 10Ω and a resistance of 1 Ω. If its excitation is such that on open circuit the p.d. would be 5000 V, calculate the maximum load the machine can supply to the external circuit before dropping out of step and the corresponding armature current and p.f. [2864 kW, 787 A, 0.551]A 50 kVA, 500 V, single phase alternator gives 700 V on open circuit at the field current of 15 A. While on short circuit a short current of 375 flows for the same field current. Assuming the armature resistance of 0.8 ohm, calculate (1) Synchronous impedance and (2) synchronous reactanceThe effective resistance of a 2200 V, 50 Hz, 440 KVA, 1 -phase alternator is 0.5 ohm. On short-circuit, a field current of 40 A gives the full load current of 200 AS. The electromotive force on open-circuits with same field excitation is 1160 V. Then the synchronous impedance and reactance is _______ ohm and _______ ohm respectively.
- A 1500 KVA, star connected 2300v, 3 phase salient pole synchronous generator has reactance ph/95.1xd and phase/40.1xq All losses may be neglected. Find the excitation voltage for operation at rated KVA and power factor of 0.85 lagging.A 1500 kVA, star-connected, 2300 V, 3-phase, salient-pole synchronous generator has reactance Xd= 1.95 ohm and Xq= 1.40 ohm per phase. All losses may be neglected. Find the excitation voltage for operation at rated kVA and power factor of 0.85 lagging.A 3Ø, Y-connected alternator is rated at 1,600KVA, 13.5KV. The armature effective AC resistance per phase is 1.5Ω. The percentage regulation for a load of 1,280kW at unity power factor is 3.5%. Determine:(a) synchronous reactance of the alternator(b) %VR at full-load 0.8pf leading(c) What is the effect on %VR value if taken at half-load lagging pf? Justify andexplain briefly your answer on one(1) sentence.
- The impedance of the stator winding of a 440 V, star-connected, three-phase inductio nmotor is (0,2 + j0,8) Ω per phase and that of the rotor is (0,06 + j0,25) Ω per phase atstandstill. The turns ratio is 2. Using the approximate equivalent circuit, calculate therotor current and the power factor when the slip is reduced to 25% by injecting16,2 V/phase into the rotor circuit without any phase compensation.A 500 kVA, 11 kV, 3-phase star-connected alternator has the following data : Friction and windage loss = 1500 W Open-circuit core loss = 2500 W Effective armature resistance per phase 40 ohm Field copper loss = 1000 W Find (a) alternator efficiency of half-full load and at 0.8 power factor lagging, (b) maximum efficiency of the alternator.A 400-V, 3-phase induction motor load takes 900 kVA at a power factor of 0.707. Calculate the KVA rating of the capacitor bank to raise the resultant power factor of the installation of 0.866 lagging. Find also the resultant power factor when the capacitors are in circuit and the motor load has fallen to 300 kVA at 0.5 power factor.
- A 10 pole wave wound shunt generator delivers 200A at a terminal voltage of 245V. Ra and Rsh are 0.02ohm and 60ohm respectively. Neglecting brush drop, determine (i) armature current (ii) current per parallel path (iii) generated voltage (iv) power developed.A long shunt generator delivers 25kW at 220V. The shunt, series and armature resistances are 50ohms, 0.02ohms, and 0.05ohms respectively, calculate the generated emf.A 15kVA, 440V, single-phase alternator draws a field current of 5A at rated load. With the same field current, the open circuit emf and short-circuit current are 100V and 80A respectively. The ohmic resistance of the armature between terminals is 0.12 ohm. The ratio of effective to ohmic resistance maybe taken as 1.1. Determine the voltage regulation (in %) when the load is purely resistive.