The plant capacity of a 3Ø generating station consists of two 10,000 KVA alternators of reactance 12% each and one 5,000 KVA alternator of reactance 18%. The alternators are connected to the station bus-bar from which load via a transmission line is taken through three 5,000 KVA transformers each having a reactance of 5%. Determine the maximum fault in MVA which the circuit breakers on low voltage side of the transformer may have to deal with. Let base be 10,000 KVA.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.36P: Three single-phase two-winding transformers, each rated 25MVA,34.5/13.8kV, are connected to form a...
icon
Related questions
Question

help asap

The plant capacity of a 3Ø generating station consists of two 10,000 KVA alternators of
reactance 12% each and one 5,000 KVA alternator of reactance 18%. The alternators are
connected to the station bus-bar from which load via a transmission line is taken through
three 5,000 KVA transformers each having a reactance of 5%. Determine the maximum
fault in MVA which the circuit breakers on low voltage side of the transformer may have
to deal with. Let base be 10,000 KVA.
Transcribed Image Text:The plant capacity of a 3Ø generating station consists of two 10,000 KVA alternators of reactance 12% each and one 5,000 KVA alternator of reactance 18%. The alternators are connected to the station bus-bar from which load via a transmission line is taken through three 5,000 KVA transformers each having a reactance of 5%. Determine the maximum fault in MVA which the circuit breakers on low voltage side of the transformer may have to deal with. Let base be 10,000 KVA.
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
8051 Microcontroller
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning