The standard addition method is used to analyze a sample of a river water for mercury. Solution A is made by pipetting 5.00 mL of undiluted sample in to a 10 ml volumetric flask and filling to the mark with DI water. Solution B is made by pipetting 5.00 mL of undiluted sample and 3.00 mL of 15.0 ppb of Hg standard into same 10.0 mL volumetric flask and filling to the mark with DI. Solution A and B are analyzed using atomic absorption spectroscopy and give a percent transmittance values of 56 % and 33 % respectively (not blank corrected). A blank has a transmittance of 96%. What is the corrected absorbance of both solution A and B? NA Solution A: 0.123 Solution B: 0.463 O B. Solution A: 0.463 Solution B: 0.234 OC. Solution A: 0.123 Solution B: 0.234 OD. Solution A: 0.234 Solution B: 0.463

Principles of Modern Chemistry
8th Edition
ISBN:9781305079113
Author:David W. Oxtoby, H. Pat Gillis, Laurie J. Butler
Publisher:David W. Oxtoby, H. Pat Gillis, Laurie J. Butler
Chapter17: Electrochemistry
Section: Chapter Questions
Problem 80AP
icon
Related questions
Question
The standard addition method is used to analyze a sample of a river water for mercury. Solution A is made by pipetting 5.00 mL of undiluted sample in to a 10 mL volumetric flask and filling to the mark with DI
water. Solution B is made by pipetting 5.00 mL of undiluted sample and 3.00 mL of 15.0 ppb of Hg standard into same 10.0 mL volumetric flask and filling to the mark with DI.
Solution A and B are analyzed using atomic absorption spectroscopy and give a percent transmittance values of 56 % and 33 % respectively (not blank corrected). A blank has a transmittance of 96%.
What is the corrected absorbance of both solution A and B?
OA. Solution A: 0.123
Solution B: 0.463
O B. Solution A: 0.463
Solution B: 0.234
O C. Solution A: 0.123
Solution B: 0.234
O D. Solution A: 0.234
Solution B: 0.463
Transcribed Image Text:The standard addition method is used to analyze a sample of a river water for mercury. Solution A is made by pipetting 5.00 mL of undiluted sample in to a 10 mL volumetric flask and filling to the mark with DI water. Solution B is made by pipetting 5.00 mL of undiluted sample and 3.00 mL of 15.0 ppb of Hg standard into same 10.0 mL volumetric flask and filling to the mark with DI. Solution A and B are analyzed using atomic absorption spectroscopy and give a percent transmittance values of 56 % and 33 % respectively (not blank corrected). A blank has a transmittance of 96%. What is the corrected absorbance of both solution A and B? OA. Solution A: 0.123 Solution B: 0.463 O B. Solution A: 0.463 Solution B: 0.234 O C. Solution A: 0.123 Solution B: 0.234 O D. Solution A: 0.234 Solution B: 0.463
Expert Solution
steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Gravimetric Analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Principles of Modern Chemistry
Principles of Modern Chemistry
Chemistry
ISBN:
9781305079113
Author:
David W. Oxtoby, H. Pat Gillis, Laurie J. Butler
Publisher:
Cengage Learning
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
EBK A SMALL SCALE APPROACH TO ORGANIC L
EBK A SMALL SCALE APPROACH TO ORGANIC L
Chemistry
ISBN:
9781305446021
Author:
Lampman
Publisher:
CENGAGE LEARNING - CONSIGNMENT
Chemistry
Chemistry
Chemistry
ISBN:
9781133611097
Author:
Steven S. Zumdahl
Publisher:
Cengage Learning
Chemistry
Chemistry
Chemistry
ISBN:
9781305957404
Author:
Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:
Cengage Learning
Chemistry: An Atoms First Approach
Chemistry: An Atoms First Approach
Chemistry
ISBN:
9781305079243
Author:
Steven S. Zumdahl, Susan A. Zumdahl
Publisher:
Cengage Learning