Two separately excited DC generators are connected in parallel to supply a total load current of 100 A. The two generators have the following parameters: G1: R. = 0.55 N and induced E.M.F=300 V G2: R. = 0.76 N and induced E.M.F=350 V Find Mathematically: (i) The armature current of each generator, and the bus-bar voltage, (ii) The load power and the power sharing by each generator, (iii) If it requires equal copper losses for both generators, what must be done to achieve this? Determine that for the same load current. (iv) The power sharing by each generator for this case.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter11: Transient Stability
Section: Chapter Questions
Problem 11.3P
icon
Related questions
Question
Two separately excited DC generators are connected in parallel to supply a total load
current of 100 A. The two generators have the following parameters:
G1: R. = 0.55 N and induced E.M.F=300 V
G2: R. = 0.76 N and induced E.M.F=350 V
Find Mathematically:
(i) The armature current of each generator, and the bus-bar voltage,
(ii) The load power and the power sharing by each generator,
(iii) If it requires equal copper losses for both generators, what must be done to achieve
this? Determine that for the same load current.
(iv) The power sharing by each generator for this case.
Transcribed Image Text:Two separately excited DC generators are connected in parallel to supply a total load current of 100 A. The two generators have the following parameters: G1: R. = 0.55 N and induced E.M.F=300 V G2: R. = 0.76 N and induced E.M.F=350 V Find Mathematically: (i) The armature current of each generator, and the bus-bar voltage, (ii) The load power and the power sharing by each generator, (iii) If it requires equal copper losses for both generators, what must be done to achieve this? Determine that for the same load current. (iv) The power sharing by each generator for this case.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps with 7 images

Blurred answer
Knowledge Booster
Stability Analysis in Power System
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning