Given:
Qa=Qf=96
Da=Df=4.5
Db=1
Dc=0.5
Dd=1.25
De=0.8
Pipes B-E are the same length (500 ft)If losses in the pipe connections labeled A, and F are negligible, the parallel pipes are made ofrecently installed Galvanized iron, and the only head losses incurred are due to the parallelnetwork. As hint: this problem is easier to solve using the Hazen-Williams (HW) equation. Feelfree to use the Darcy-Weisbach (DW) equation as well. Solution will use HW.a Determine the total head loss going from A to Fb Determine the flowrates in pipes B – E
A lecture room with an area of 50 square meters (5m at the shortest side) accommodates 45 students. The room is being utilized at 7:30am to 7:30 pm from monday to wednesday for 18 weeks( 1 semester). The fixture has a 0.35 coefficient of utilization and maintenance factor of 0.80.
A. Solve for the number of fixtures per 2.5m x 5m. (Use 2-lamp F30T12/D/RS ALTO 30PK - 1950lm)
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.Similar questions
- List the minimum trade size of Type EMT for each of the following applications. Assume the use of conductors with THHN insulation. (Objective 12-1) a. Six 14 AWG _______ b. Six 12 AWG ______ c. Three 10 AWG ______ d. Four 8 AWG _____arrow_forwardDescribe how a white Insulated conductor in a cable assembly is reidentified as an ungrounded hot conductor. Name the NEC section that covers this wiring situation. (Objective 9-4)arrow_forwardThe maximum demand for one electric range rated not over 12 kW is____________. This Information is found in NEC Table ____________. (Objective 6-7)arrow_forward
- Describe the purpose of an LB conduit body used in a residential service entrance Installation that uses electrical conduit. (Objective 8-1)arrow_forwardThe minimum amount of free conductor required at an electrical box used in residential wiring for termination purposes is______________ inches. As long as the box has no dimension Larger than 8 Inches (200 mm), there must be at Least ______ inches of free conductor extending out from the box opening. Name the NEC section that covers this wiring practice. (Objective 9-3)arrow_forwardDescribe how a conductor that is larger than 6 AWG can be identified as a grounding conductor. Name the NEC section that covers this wiring situation. (Objective 9-4)arrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- Residential Construction Academy: House Wiring (M...Civil EngineeringISBN:9781337402415Author:Gregory W FletcherPublisher:Cengage LearningResidential Construction Academy: House Wiring (M...Civil EngineeringISBN:9781285852225Author:Gregory W FletcherPublisher:Cengage Learning
Residential Construction Academy: House Wiring (M...
Civil Engineering
ISBN:9781337402415
Author:Gregory W Fletcher
Publisher:Cengage Learning
Residential Construction Academy: House Wiring (M...
Civil Engineering
ISBN:9781285852225
Author:Gregory W Fletcher
Publisher:Cengage Learning
02 - Overview of Circuit Components - Resistor, Capacitor, Inductor, Transistor, Diode, Transformer; Author: Math and Science;https://www.youtube.com/watch?v=RHpo4wKo8pQ;License: Standard Youtube License