Question
Chapter 9, Problem 11R
To determine
Name the cover types used with 4in. square outlet boxes.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
QUESTION 25
Type TC cable shall not be _____.
a.
installed where it will be exposed to physical damage
b.
all of these
c.
installed outside of a race-way or cable tray system, unless permitted in 336.10(4), 336.10(7), 336.10(9), and 336.10(10)
d.
used where exposed to direct rays of the sun, unless identified as sunlight resistant
QUESTION 9
When a ground wire is connected to an interior gas piping system and the underground portion of the gas pipe into the building is plastic, which of the following is (or are) true?
a
A.This would be approved by code as the gas pipe is only being bonded to the electrical system.
b
B.This installation would be approved by code, as the gas pipe is not a grounding electrode.
c
C.Both A and B
d
D.Neither A nor B
In order to wire a post light, a homeowner purchased some single-conductor cable that was marked as suitable for direct burial in the ground. A separate equipment grounding conductor to the post light was not carried. Instead, the bottom of the metal post, buried 2 ft (0.6 m) into the ground, was used as a ground for the post light. The inspector “red tagged” (turned down) the installation. Who is right—the homeowner or the electrical inspector?
Explain.
Chapter 9 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Ch. 9 - What circuit supplies the Master Bedroom?Ch. 9 - What unique type of electrical protection is...Ch. 9 - Prob. 4RCh. 9 - Prob. 5RCh. 9 - Prob. 6RCh. 9 - What is the estimated load in volt-amperes for the...Ch. 9 - Prob. 8RCh. 9 - How many conductors enter the ceiling fan/light...Ch. 9 - What type and size of box may be used for the...Ch. 9 - Prob. 11R
Ch. 9 - a. Does the circuit for the Master Bedroom have a...Ch. 9 - Approximately how many feet (meters) of 2-wire...Ch. 9 - If the cable is laid in notches in the corner...Ch. 9 - Prob. 15RCh. 9 - Prob. 16RCh. 9 - Prob. 17RCh. 9 - Prob. 18RCh. 9 - Prob. 19RCh. 9 - Show your calculations of how to select a proper...Ch. 9 - Prob. 21RCh. 9 - The following is a layout of the lighting circuit...Ch. 9 - Prob. 23RCh. 9 - Prob. 24RCh. 9 - May a standard electronic dimmer be used to...Ch. 9 - Prob. 26R
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Refer to the specifications in the back of this text following Chapter 33. a. What electrical codes must be conformed to? ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ b. What is the wiring method to be used in the workshop? ________________________________________________________________________ c. What size conductors are to be used for the lighting branch circuits? ______________________ AWG the small-appliance branch circuits? ______________________ AWG d. What section of the specifications tells us the size of the service entrance to be installed for this residence?arrow_forwardAssuming that an outlet box for the entry ceiling has a fixture stud but has external cable clamps, what size box could be installed? Show calculations for both metal and nonmetallic boxes. ___________arrow_forwardWhat section of the NEC covers grounding?arrow_forward
- The recessed fluorescent luminaires installed in the ceiling of the recreation room of this residence are connected with trade size flexible metal conduit. These flexible connections are commonly referred to as fixture whips. Does the flexible metal conduit provide adequate grounding for the luminaires, or must a separate equipment grounding conductor be installed? ________________arrow_forwardIn order to wire a post light, a homeowner purchased some single-conductor cable that was marked as suitable for direct burial in the ground. A separate equipment grounding conductor to the post light was not carried. Instead, the bottom of the metal post, buried 2 ft (0.6 m) into the ground, was used as a ground for the post light. The inspector red tagged (turned down) the installation. Who is rightthe homeowner or the electrical inspector? Explain. ___________________ ___________________ ___________________arrow_forwardWhat is the recommended height of a meter socket from the ground?arrow_forward
- a. The Code requires a minimum of two small-appliance circuits in a kitchen. Is it permitted to connect a receptacle in a dining room to one of the kitchen small-appliance circuits? _______________ What Code section applies to this situation? _______________ b. Are outdoor weatherproof receptacles permitted to be connected to a 20-ampere small-appliance circuit? _______________ c. Receptacles located above the countertops in the kitchen must be supplied by at least _______________ 20-ampere small-appliance circuits.arrow_forwardWhen calculating a dwelling lighting load on the "volt-ampere per ft" basis, the receptacle load used for floor lamps, table lamps, and so forth arearrow_forwardThe following problems pertain to luminaires in clothes closets. a. Does the Code permit bare incandescent lamps to be installed in porcelain key-less or porcelain pull-chain lampholders? ________________ b. Does the Code permit bare fluorescent lamp luminaires to be installed? ________________ c. Does the Code permit pendant lampholders to be installed? ________________ d. What is the minimum clearance from the storage area to surface-mounted incandescent luminaires? ________________ e. What is the minimum clearance from the storage area to surface-mounted fluorescent luminaires? ________________ f. What is the minimum distance between recessed incandescent or recessed fluorescent luminaires and the storage area? ________________ g. Define the storage area. ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ ______________________________________ h. If a clothes hanging rod is installed where there is access from both sides, such as might be found in a large walk-in clothes closet, define the storage area under that rod. ___________________________________ ___________________________________arrow_forward
- The following is a layout of the lighting circuit for the Laundry, Powder Room, Rear Entry Hall, and Attic. Complete the wiring diagram using colored pens or pencils to indicate conductor insulation color. The GFCI receptacle in the Powder Room is not shown in the diagram because it is connected to a separate circuit, B21.arrow_forwardWhat type and size of box may be used for the ceiling fan/light wall box?arrow_forwardelectrical wiring 20th edition residential book chapter 12 review question #27 The following is a layout for the lighting circuit for the Kitchen. Complete the wiring diagram using colored pens or pencils to show the conductors’ insulation color.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENTDelmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning