3) Three-phase, delta connected, 50HZ, 26 kVA, 400 Volt cylindrical pole synchronous generator is operated at rated power and a load with a power factor of 0.866 backward. It has been found that the power angle is 6° while operating at this load. According to these conditions and if armature resistance is neglected, a.) Find the induced voltage (Ef) and synchronous reactance (Xs) at the armature of the synchronous generator. b.) In case it operates at rated load, find the induced power in its armature and the terminal (output) power and examine the result.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.38P: Consider a three-phase generator rated 300MVA,23kV, supplying a system load of 240 MA and 0.9 power...
icon
Related questions
Question
None
3) Three-phase, delta connected, 50HZ, 26 kVA, 400 Volt
cylindrical pole synchronous generator is operated at rated
power and a load with a power factor of 0.866 backward. It
has been found that the power angle is 6° while operating at
this load. According to these conditions and if armature
resistance is neglected,
a.) Find the induced voltage (Ef) and synchronous reactance
(Xs) at the armature of the synchronous generator.
b.) In case it operates at rated load, find the induced power in
its armature and the terminal (output) power and examine the
result.
Transcribed Image Text:3) Three-phase, delta connected, 50HZ, 26 kVA, 400 Volt cylindrical pole synchronous generator is operated at rated power and a load with a power factor of 0.866 backward. It has been found that the power angle is 6° while operating at this load. According to these conditions and if armature resistance is neglected, a.) Find the induced voltage (Ef) and synchronous reactance (Xs) at the armature of the synchronous generator. b.) In case it operates at rated load, find the induced power in its armature and the terminal (output) power and examine the result.
Expert Solution
steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
KVL and KCL
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning