A domestic lighting installation having 24, 70 W lamps is operated as follows: 7 lamps 6 Pm till 8 pm 10 lamps 8 pm till 10 pm 3 lamps 10 pm till 11.45 pm Determine the demand factor and daily load factor.
Q: California Electrical Transmission Company has to supply the demand of four companies in different…
A: The diversity factor is defined as The variety factor is the ratio of the total of individual…
Q: The two-wattmeter method produces wattmeter readings P2 = 800 W Wand P1= 560 W when connected to a…
A:
Q: A 3-phase, 420 V, 60 Hz, Y-connected synchronous generator, with a synchronous reactance of 1.20 Ohm…
A: As we have given: VL=420 Vf=60 HzXs=1.2 ΩZs=j1.2 Ωδ=30°Pout=110 kW Step 1: Find E As we know that,…
Q: A generating station supplies the following loads: 15000 kW, 12000 kW, 8500 kW, 6000 kW and 450 kW.…
A: Total loads are 15000 kW, 12000 kW, 8500 kW, 6000 kW and 450 kW.
Q: The load on an installation is 800 kW, 0.8 lagging power factor which works for 3000 hours per…
A:
Q: 7. A power station has to meet the following load demand : 50 kW Load A between 10 A.M. and 6 P.M.…
A: The solution can be achieved as follows.
Q: Q1. High load factor indicates Ocost of generation per unit power is increased O total plant…
A: Here question is high load factor indicates what
Q: The domestic load in residential building is used in the following manner Fluorescent lamps 55 watt…
A:
Q: 18.) A load of 35 kVA, with .65 power factor lagging is connected to a 230 volts line. How much…
A:
Q: B1, (i) A domestic lighting installation having 25, 75 W lamps is operated as follows: 7 lamps 6 Pm…
A: According to the question we have to calculate the value of daily load factor, monthly load factor,…
Q: It has been desired to install a diesel power station to supply power in a suburban area having the…
A: As per the Bartleby policy we can answer only three sub parts at a time. As you have not mentioned,…
Q: Assume the load on the substation bus drops to 240 kW and 600 magnetizing kVAR. Also assume the…
A:
Q: H. W.: A 3-phase overhead transmission line is being supported by three disc insulators. The…
A:
Q: Problem #16: A substation operating at full load of 1200 kVA supplies a load at 0.7 power factor…
A:
Q: A 11 kV,5 MVA, 10 km long uniformly distributed load radial feeder delivering a load of 3 MVA at the…
A: 10 km line 3MVA at the power factor 0.8 lagging. Radial distribution impedance z= 0.15+j0.5 ohm…
Q: e is 0.3Ω / km. calculate the efficiency and regulation of the line for 0.8 lagging power factor.
A:
Q: The three-phase average power rating of the central processing unit (CPU) on a mainframe digital…
A: Given data, The value of average power of the CPU is P = 22695 W. The three-phase line voltage is…
Q: Calculate the continuous power that will be available from hydroelectric plant having an available…
A: Givem Data: Efficiency = 0.96 * 0.86 * 0.97 density = 1000 head h = 300 m g = 9.81 Q = massflow =…
Q: The domestic load in residential building is used in the following manner : Fluorescent lamps 55…
A:
Q: on of the Tariff characteristics is to be fair by charging the big consumer a high rate than the…
A: The first question is subjective and hence out of scope. The solution for rest two questions is as…
Q: B1, (i) A domestic lighting installation having 29, 70 W lamps is operated as follows: 7 lamps 6 Pm…
A:
Q: 50 Hz, 250 V single phase power line has the following loads placed across it in parallel; 4 kW at a…
A: Using power triangle relations find active and reactive power of each load then add them to get…
Q: QI//A power plant has to meet the following loud demand: Load A: 100 MW from 8 AM - 6 PM Load B: 150…
A:
Q: an overhead transmission line has a span of 220 meters the conductor waiting 0.604 kg/m.What will be…
A: Given: Span, L=220 m Weight of conductor, w=0.604 kg/m Tension, T=2879 kg
Q: Voltage between 1 kV and 50 kV is defined as: A.Very High Voltage B.Medium Voltage C.Low Voltage…
A: The solution is given below
Q: A single phase transmission line is delivering 460 kVA load at 11 kV. Its resistance is 6.5 Q and…
A: Given: A single phase transmission line is delivering power to load SL=460 kVAVL=11 kV…
Q: A power station has a daily load cycle as under; 260MW for 6 hours; 200MW for 8 hours; 160MW for 4…
A: The load factor (LF) of a power station is the ratio of average load (AL) on power station to…
Q: Q1.An industrial load can be supplied on the following alternative tariffs. (a) H.V. supply at Rs.…
A: An transformer is a device used for the conversion of electrical energy from one AC circuit to…
Q: 4. The power factor of a certain load is corrected to 0.9 lagging with the nddition of 20 kvar of…
A: Given, 0.9 lagging addition od 20KVA of capacitors final KVA value is 185
Q: A Single-Phase Overhead Transmission Line delivers 1100 KW at 23 KV at 0.825 pf lagging. If the…
A: Current=powervoltage×power factor. Efficiency =output powerinput power.
Q: A 3-ph, 3-wire balanced load with a lagging power factor is supplied at 400 between lines. A…
A: A wattmeter is a device used for measuring power, the unit of power is the watt. The three-phase…
Q: (II) If 35 MW of power at 45 kV (rms) arrives at a town froma generator via 4.6Ω transmission…
A:
Q: In Fig. below two wattmeters are properly connected to the unbalanced load supplied by a balanced…
A: The line-line voltage is, Vab=208∠0o V Vbc=208∠120o V (a) The current through impedance between 'A'…
Q: 1.3. The annual load of a substation is given in the following table. During each month, the power…
A: Below are the codes required to generate the load curve using barcycle function.
Q: What is the Total Actual Energy Generated by Davao Power Plant if there are (4) substation with 1.12…
A:
Q: A single phase 11 kV line with a length of 15 km is to transmit 500 kVA. The inductive reactance of…
A: Given,The length is 15 km.The inductive reactance is,
Q: 7. Two wattmeters are connected to measure the input to a 400 V: 3-phase, connected motor outputting…
A: Given Data: V = 400 V motor output = 24.4 kW pf = 0.4 lag Efficiency = 80%
Q: The following annual data are from a 160 MW steam turbine-generator plant. Gross generation is…
A: Given Annual data of the 160 MW steam turbine-generator plantGross generation is 780000 MWHNet…
Q: Impedance of a single phase 10 km transmission line is 60 ohm/ km. 316.8 kW line feeds the load with…
A: Given: Receiving end power (PR)=316.8 kWReceiving end Voltahe (VR)=3.3 kVLoad P.F=0.8 (Lagging)Line…
Q: Question 2. A 3.5 kW motor with 0.94 lagging power factor is supplied by a single phase power…
A: Note: We are authorized to answer three subparts at a time, since you have not mentioned which part…
Q: 4.) A load of 23 kVA, with .65 power factor lagging is connected to a 240 volts line. How much…
A:
Q: A single phase transmission line is delivering 450 kVA load at 12 kV. Its resistance is 7 0 and…
A: In this question we will find voltage regulation and efficiency of transmission line...
Q: A11 kV,15 km length primary feeder connected to a balanced load of 950 kW at a power factor of 0.85…
A: We assumed three phase feeder as nothingI is mentioned about single phase or three phase. given…
Q: a single line transmission line having 500 kva load at 2kv it resistance is 0.2 ohm and inductive…
A: Given data, A single transmission line having S=500 kVAVR=2 kVR=0.2 ΩXL=0.2 ΩPf cosϕR=0.707 leading…
Q: 6. Two alternators running in parallel supply a lighting load of 2000KW and a motor load of 4000KW…
A: In this question we need to find a output power and power factor of second alternator for the given…
Q: H. W.: A 3-phase overhead transmission line is being supported by three disc insulators. The…
A: Given, Number of insulator disc (n)=3 Voltage across the top unit (V1)= 9 kV Voltage across the…
Q: A generating station supplies the following loads: 15000 kW, 12000 kW, 8500 kW, 6000 kW and 450 kW.…
A: For the given loads 15000 kW, 12000 kW, 8500 kW, 6000 kW, 450 kW. Maximum demand = 22000 kW. annual…
Q: A generating station supplies the following loads : 15000 kW, 12000 kW, 8500 kW, 6000 kW and 45 kW.…
A: The solution can be achieved as follows.
Step by step
Solved in 2 steps
- A 50 Hz, 250 V single phase power line has the following loads placed across it in paralell; 4 kW at a pf of 0. 8 lagging; 6 kVA at a pf of 0.6 lagging; 5 kVA which includes 1.2 kVAR leading. Determine the overall pf of the system and the capacitance of the capacitor which, if connected across the mains restore the power factor to unity.The tariff in force is Rs 150 per kVA of maximum demand and 8 paise per unit consumed. If the load factor is 30%, find the overall cost per unit at (i) unity p. f. and (ii) 0.85 p. f.A transmission line has an actual impedance of 18 ohms, compute for the per unit impedance of this line assume Vbase = 2400, Sbase = 100kVA power factor at unity p.f. round answer to 4 decimal places.
- A generating station supplies the following loads : 15000 kW, 12000 kW, 8500kW, 6000 kW and 450 kW. The station has a maximum demand of 22000 kW. The annual loadfactor of the station is 48%.Calculate (i) the number of units supplied annually (ii) the diversity factor and (iii) the demandfactor.q22/ A single phase, 50 Hz, overhead transmission line supplies 1300 kW at 26 kV, 0.65 p.f. lagging. The total resistance and line inductive reactance of the line are 4.75 Ω and 7.75 Ω respectively. Calculate the sending end voltage, voltage regulation, sending end power factor and efficiency of transmissionA 50 Hz, 250 V single phase power line has the following loads placed across it in parallel; 4 kW ata pf of 0. 8 lagging; 6 kVA at a pf of 0.6 lagging; 5 kVA which includes 1.2 kVAR leading. Determinethe overall pf of the system and the capacitance of the capacitor which, if connected across themains restore the power factor to unity.
- 1. Voltage between 1 kV and 50 kV is defined as: A.Very High Voltage B.Medium Voltage C.Low Voltage D.High Voltage A factory consumes 400, 000 kVAh in a year witth the yearly average power factor 0.75. Calculate the average demand and percentage of annual load factor if the maximum demand is 120kW. A.Average demand = 44.25kW, Load factor = 29% B.Average demand = 44.25kW, Load factor = 39% C.Average demand = 34.25kW, Load factor = 29% D.Average demand = 34.25kW, Load factor = 39% The example of low voltage system is: A.Three-phase, 4-wire, 415 V, up to 45 kVA maximum demand B.Three-phase, 3-wire, 66 kV, 132 kV and 275 kV for exceptionally large load of 25 MVA maximum demand C.Three-phase, 3-wire, 11 kV for load of 1000 kVA maximum demand and above D.Three-phase, 3-wire, 22 kV or 33 kV for load of 5000 kVA maximum demand and above A load rises from zero to 20 kW instantaneosly and stays constant for 2 minutes, then rises about 40…A power station has to meet the following load demand : Load A 50 kW between 10 A.M. and 6 P.M. Load B 30 kW between 6 P.M. and 10 P.M. Load C 20 kW between 4 P.M. and 10 A.M. Plot the daily load curve and determine (i) diversity factor (ii) units generated per day (iii) load factor.please solve this question with complete solution : A 50 Hz, 250 V single phase power line has the following loads placed across it in parallel; 4 kW ata pf of 0. 8 lagging; 6 kVA at a pf of 0.6 lagging; 5 kVA which includes 1.2 kVAR leading. Determinethe overall pf of the system and the capacitance of the capacitor which, if connected across themains restore the power factor to unity.
- 3. The voltage v(t) = 359.3 cos(wt) volts is applied to a load consisting of a 14ohm resistor in parallel with a capacitive reactance Xc = 28 ohm. Calculate (a) the instantaneous power absorbed by the resistor, (b) the instantaneous power absorbed by the capacitor, (c) the real power absorbed by the resistor, (d) the reactive power delivered by the capacitor, and (e) the load power factor.A 3-phase overhead transmission line is being supported by three disc insulators. The potentials across top unit and middle unit are 9 kV and 11 kV respectively. Calculate: a. The ratio of capacitance between pin and earth to the self-capacitance of each unit. b. The line voltage. c. String efficiency. JAns: a. 0.22 b. 35.444 kV c. 76%]5. A11 kV,15 km length primary feeder connected to a balanced load of 950 kW at a power factor of 0.85 lagging. The impedance of a feeder is 4.5 +j7.5 ohms per km.Determine the following (a) The voltage drop and power loss of the feeder, when the load is uniformly distributed (b) The voltage drop and power loss of the feeder, when the load is nonuniformly distributed.