Calculate the flux per pole required on full-load for a 50 kW, 400 V, 8-pole, 600 r.p.m. d.c. shunt generator with 256 conductors arranged in a lap-connected winding. The armature winding resistances is 0.1 Q, the shunt field resistance is 200 Q and there is a brush contact voltage drop of 1 V at each brush on full- [0.162 Wb] 5. load. Calculate the flux in a 4-pole dynamo with 722 armature conductors generating 500 V when running at 1000 r.p.m. when the armature is (a) lap connected (b) wave connected. [(a) 41.56 mWb (b) 20.78 mWb] (City & Guilds, London) 7. A 4-pole machine running at 1500 r.p.m. has an armature with 90 slots and 6 conductors per slot. The flux per pole is 10 mWb. Determine the terminal e.m.f. as d.c. Generator if the coils are lap-connected. If the current per conductor is 100 A, determine the electrical power. [810 V, 324 kW] (London Univ.) 8. An 8-pole lap-wound d.c. generator has 120 slots having 4 conductors per slot. If each conductor can carry 250 A and if flux/pole is 0.05 Wb, calculate the speed of the generator for giving 240 V on open circuit. If the voltage drops to 220 V on full load, find the rated output of the machine. [600 V, 440 kW
Calculate the flux per pole required on full-load for a 50 kW, 400 V, 8-pole, 600 r.p.m. d.c. shunt generator with 256 conductors arranged in a lap-connected winding. The armature winding resistances is 0.1 Q, the shunt field resistance is 200 Q and there is a brush contact voltage drop of 1 V at each brush on full- [0.162 Wb] 5. load. Calculate the flux in a 4-pole dynamo with 722 armature conductors generating 500 V when running at 1000 r.p.m. when the armature is (a) lap connected (b) wave connected. [(a) 41.56 mWb (b) 20.78 mWb] (City & Guilds, London) 7. A 4-pole machine running at 1500 r.p.m. has an armature with 90 slots and 6 conductors per slot. The flux per pole is 10 mWb. Determine the terminal e.m.f. as d.c. Generator if the coils are lap-connected. If the current per conductor is 100 A, determine the electrical power. [810 V, 324 kW] (London Univ.) 8. An 8-pole lap-wound d.c. generator has 120 slots having 4 conductors per slot. If each conductor can carry 250 A and if flux/pole is 0.05 Wb, calculate the speed of the generator for giving 240 V on open circuit. If the voltage drops to 220 V on full load, find the rated output of the machine. [600 V, 440 kW
Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter12: Power System Controls
Section: Chapter Questions
Problem 12.4P
Related questions
Question
![Calculate the flux per pole required on full-load for a 50 kW, 400 V, 8-pole, 600 r.p.m. d.c. shunt
generator with 256 conductors arranged in a lap-connected winding. The armature winding resistances is 0.1
Q, the shunt field resistance is 200 Q and there is a brush contact voltage drop of 1 V at each brush on full-
[0.162 Wb]
5.
load.
Calculate the flux in a 4-pole dynamo with 722 armature conductors generating 500 V when running
at 1000 r.p.m. when the armature is (a) lap connected (b) wave connected.
[(a) 41.56 mWb (b) 20.78 mWb] (City & Guilds, London)
7.
A 4-pole machine running at 1500 r.p.m. has an armature with 90 slots and 6 conductors
per
slot.
The flux per pole is 10 mWb. Determine the terminal e.m.f. as d.c. Generator if the coils are lap-connected.
If the current per conductor is 100 A, determine the electrical power.
[810 V, 324 kW] (London Univ.)
8.
An 8-pole lap-wound d.c. generator has 120 slots having 4 conductors per slot. If each conductor
can carry 250 A and if flux/pole is 0.05 Wb, calculate the speed of the generator for giving 240 V on open
circuit. If the voltage drops to 220 V on full load, find the rated output of the machine.
[600 V, 440 kW]](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2Fc820ac33-53cf-404f-ac9b-5665b8dabce8%2Fc443dfdd-ba31-4924-aec3-929e76779830%2Fb8v1wzj_processed.png&w=3840&q=75)
Transcribed Image Text:Calculate the flux per pole required on full-load for a 50 kW, 400 V, 8-pole, 600 r.p.m. d.c. shunt
generator with 256 conductors arranged in a lap-connected winding. The armature winding resistances is 0.1
Q, the shunt field resistance is 200 Q and there is a brush contact voltage drop of 1 V at each brush on full-
[0.162 Wb]
5.
load.
Calculate the flux in a 4-pole dynamo with 722 armature conductors generating 500 V when running
at 1000 r.p.m. when the armature is (a) lap connected (b) wave connected.
[(a) 41.56 mWb (b) 20.78 mWb] (City & Guilds, London)
7.
A 4-pole machine running at 1500 r.p.m. has an armature with 90 slots and 6 conductors
per
slot.
The flux per pole is 10 mWb. Determine the terminal e.m.f. as d.c. Generator if the coils are lap-connected.
If the current per conductor is 100 A, determine the electrical power.
[810 V, 324 kW] (London Univ.)
8.
An 8-pole lap-wound d.c. generator has 120 slots having 4 conductors per slot. If each conductor
can carry 250 A and if flux/pole is 0.05 Wb, calculate the speed of the generator for giving 240 V on open
circuit. If the voltage drops to 220 V on full load, find the rated output of the machine.
[600 V, 440 kW]
Expert Solution
![](/static/compass_v2/shared-icons/check-mark.png)
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution!
Trending now
This is a popular solution!
Step by step
Solved in 3 steps with 2 images
![Blurred answer](/static/compass_v2/solution-images/blurred-answer.jpg)
Recommended textbooks for you
![Power System Analysis and Design (MindTap Course …](https://www.bartleby.com/isbn_cover_images/9781305632134/9781305632134_smallCoverImage.gif)
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
![Power System Analysis and Design (MindTap Course …](https://www.bartleby.com/isbn_cover_images/9781305632134/9781305632134_smallCoverImage.gif)
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning