Co(II) was used as an internal standard to analyze a sample of Ti(IV) with atomic absorption spectroscopy (AAS). A standard mixture containing 1.22 ug Co/ml and 2.20 ug Ti/mL measured by AAS produced a signal-to-signal ratio of 2.35 Ti : 1.00 Co. A mixture was prepared by combining 6.00 mL of a Ti(IV) solution of unknown concentration with 4.00 mL of a 12.4 ug/mL solution of Co(II). The absorbance of the mixture at the Ti(IV) wavelength was 0.104 and the absorbance at the Co(II) wavelength was 0.189. Determine the concentration, in moles per liter, of Ti(IV) in the original unknown solution. concentration: M Ti(IV)

Fundamentals Of Analytical Chemistry
9th Edition
ISBN:9781285640686
Author:Skoog
Publisher:Skoog
Chapter26: Molecular Absorption Spectrometry
Section: Chapter Questions
Problem 26.32QAP
icon
Related questions
Question
Co(II) was used as an internal standard to analyze a sample of Ti(IV) with atomic absorption spectroscopy (AAS). A standard
mixture containing 1.22 ug Co/mL and 2.20 ug Ti/mL measured by AAS produced a signal-to-signal ratio of
2.35 Ti : 1.00 Co.
A mixture was prepared by combining 6.00 mL of a Ti(IV) solution of unknown concentration with 4.00 mL.of a 12.4 ug/mL
solution of Co(II). The absorbance of the mixture at the Ti(IV) wavelength was 0.104 and the absorbance at the Co(II)
wavelength was 0.189.
Determine the concentration, in moles per liter, of Ti(IV) in the original unknown solution.
concentration:
M Ti(IV)
Transcribed Image Text:Co(II) was used as an internal standard to analyze a sample of Ti(IV) with atomic absorption spectroscopy (AAS). A standard mixture containing 1.22 ug Co/mL and 2.20 ug Ti/mL measured by AAS produced a signal-to-signal ratio of 2.35 Ti : 1.00 Co. A mixture was prepared by combining 6.00 mL of a Ti(IV) solution of unknown concentration with 4.00 mL.of a 12.4 ug/mL solution of Co(II). The absorbance of the mixture at the Ti(IV) wavelength was 0.104 and the absorbance at the Co(II) wavelength was 0.189. Determine the concentration, in moles per liter, of Ti(IV) in the original unknown solution. concentration: M Ti(IV)
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Nuclear Magnetic Resonance
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Fundamentals Of Analytical Chemistry
Fundamentals Of Analytical Chemistry
Chemistry
ISBN:
9781285640686
Author:
Skoog
Publisher:
Cengage
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
Appl Of Ms Excel In Analytical Chemistry
Appl Of Ms Excel In Analytical Chemistry
Chemistry
ISBN:
9781285686691
Author:
Crouch
Publisher:
Cengage
Macroscale and Microscale Organic Experiments
Macroscale and Microscale Organic Experiments
Chemistry
ISBN:
9781305577190
Author:
Kenneth L. Williamson, Katherine M. Masters
Publisher:
Brooks Cole