The following standard solutions were used to assess Mg in a river near Pengkalan Hulu. A graphite furnace atomic absorption spectrometer with a slot burner was utilised in the experiment. Solution Mg concentration (ppb) Absorbance Standard solution I 5.0 0.06 Standard solution II 10.0 0.71 Standard solution III 20.0 2.85 Standard solution IV 30.0 5.95 Standard solution V 40.0 12.20 Standard solution VI 50.0 18.20 Standard solution VII 100.0 30.10 Standard solution VIII 150.0 54.50 Standard solution IX 200.0 56.20 Standard solution X 250.0 58.40 Unknown PH-WR ? 55.30 Unknown PH-YH ? 44.60 (i). Using the standard solutions, construct an appropriate calibration curve (graph paper is not required). (ii). Identify the concentrations of unknown PH-WR and PH-YH. Show the way of getting the values. (iii). Explain whether the calibration curve can be used to determine the concentrations of unknown PH-WR and PH-YH.

Principles of Instrumental Analysis
7th Edition
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Chapter15: Molecular Luminescence Spectrometry
Section: Chapter Questions
Problem 15.16QAP
icon
Related questions
Question

Kindly answer this question i, ii & iii

The following standard solutions were used to assess Mg in a river near
Pengkalan Hulu. A graphite furnace atomic absorption spectrometer with a
slot burner was utilised in the experiment.
Solution
Mg concentration (ppb)
Absorbance
Standard solution I
5.0
0.06
Standard solution II
10.0
0.71
Standard solution III
20.0
2.85
Standard solution IV
30.0
5.95
Standard solution V
40.0
12.20
Standard solution VI
50.0
18.20
Standard solution VII
100.0
30.10
Standard solution VIII
150.0
54.50
Standard solution IX
200.0
56.20
Standard solution X
250.0
58.40
Unknown PH-WR
?
55.30
Unknown PH-YH
?
44.60
(i). Using the standard solutions, construct an appropriate calibration curve
(graph paper is not required).
(ii). Identify the concentrations of unknown PH-WR and PH-YH. Show the
way of getting the values.
(i). Explain whether the calibration curve can be used to determine the
concentrations of unknown PH-WR and PH-YH.
Transcribed Image Text:The following standard solutions were used to assess Mg in a river near Pengkalan Hulu. A graphite furnace atomic absorption spectrometer with a slot burner was utilised in the experiment. Solution Mg concentration (ppb) Absorbance Standard solution I 5.0 0.06 Standard solution II 10.0 0.71 Standard solution III 20.0 2.85 Standard solution IV 30.0 5.95 Standard solution V 40.0 12.20 Standard solution VI 50.0 18.20 Standard solution VII 100.0 30.10 Standard solution VIII 150.0 54.50 Standard solution IX 200.0 56.20 Standard solution X 250.0 58.40 Unknown PH-WR ? 55.30 Unknown PH-YH ? 44.60 (i). Using the standard solutions, construct an appropriate calibration curve (graph paper is not required). (ii). Identify the concentrations of unknown PH-WR and PH-YH. Show the way of getting the values. (i). Explain whether the calibration curve can be used to determine the concentrations of unknown PH-WR and PH-YH.
Expert Solution
steps

Step by step

Solved in 3 steps with 1 images

Blurred answer
Knowledge Booster
Potentiometric Titrations
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
Fundamentals Of Analytical Chemistry
Fundamentals Of Analytical Chemistry
Chemistry
ISBN:
9781285640686
Author:
Skoog
Publisher:
Cengage
Appl Of Ms Excel In Analytical Chemistry
Appl Of Ms Excel In Analytical Chemistry
Chemistry
ISBN:
9781285686691
Author:
Crouch
Publisher:
Cengage