Q6: A five-bus network has generators at buses 1 and 3 rated 270 and 225 MVA, respectively. The generator sub-transient reactances plus the reactances of the transformers connecting them to the buses are each 0.3 pu on the generator rating as base. The turns ratios of the transformers are such that the voltage base in each generator circuit is equal to the voltage rating of the generator. Line impedances in pu on a 100 MVA system base are shown in Fig. below. All resistances are neglected. Using the bus impedance matrix for the network which includes the generator and transformer reactances, find the sub-transient current in a three phase fault at bus 4 and the current coming to the faulted bus over each line. Prefault current is to be neglected and all voltages are assumed to be 1 pu before the fault occurs. (2) j0.126 1.0/0° j0.168 ll 1.0/0 ll j0.1333 ll j0.1111 ll 5 j0.126 j0.210 ell j0.252 4 j0.336 hellte

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter9: Unsymmetrical Faults
Section: Chapter Questions
Problem 9.53P
icon
Related questions
icon
Concept explainers
Question
Q6: A five-bus network has generators at buses 1 and 3 rated 270 and 225
MVA, respectively. The generator sub-transient reactances plus the
reactances of the transformers connecting them to the buses are each 0.3
pu on the generator rating as base. The turns ratios of the transformers are
such that the voltage base in each generator circuit is equal to the voltage
rating of the generator. Line impedances in pu on a 100 MVA system
base are shown in Fig. below. All resistances are neglected. Using the bus
impedance matrix for the network which includes the generator and
transformer reactances, find the sub-transient current in a three phase
fault at bus 4 and the current coming to the faulted bus over each line.
Prefault current is to be neglected and all voltages are assumed to be 1 pu
before the fault occurs.
(2)
3
j0.126
1.0/0°
j0.168
0/0°
j0.1111
lll
j0.1333
j0.210
ell
j0.126
ll
j0.252 4 j0.336
hellte
Transcribed Image Text:Q6: A five-bus network has generators at buses 1 and 3 rated 270 and 225 MVA, respectively. The generator sub-transient reactances plus the reactances of the transformers connecting them to the buses are each 0.3 pu on the generator rating as base. The turns ratios of the transformers are such that the voltage base in each generator circuit is equal to the voltage rating of the generator. Line impedances in pu on a 100 MVA system base are shown in Fig. below. All resistances are neglected. Using the bus impedance matrix for the network which includes the generator and transformer reactances, find the sub-transient current in a three phase fault at bus 4 and the current coming to the faulted bus over each line. Prefault current is to be neglected and all voltages are assumed to be 1 pu before the fault occurs. (2) 3 j0.126 1.0/0° j0.168 0/0° j0.1111 lll j0.1333 j0.210 ell j0.126 ll j0.252 4 j0.336 hellte
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Load flow analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning