R, R, i (1) ら(の (の 1-s R R Fig. Equivalent Circuit of IM Three phase, four pole, 45 Hz IM is obtained to be operating at a speed of 1250 r/min with an input power of 75 kW and terminal current of 5.75 A. The stator winding resistance is 0.75 0/phase. Calculate I?R power dissipated in rotor. O a. 5525.01 W O b. 5575.25 W O c. 5515.057 W O d. 5550.05 W O e. 5535.02 W
Q: A simple power system is shown in this Fig. The generator (480 V, 10 kVA) is connected to an ideal…
A: In this question we need to find a reactive power consumed by the load in per unit
Q: onsider the one-line diagram and corresponding reactance diagram of the two-machine system nown…
A:
Q: a) Calculate the unit ramp input steady state error (e_ss) for the following control system. b)…
A:
Q: R, 40) R 1,0) Fig. Equivalent Circuit The test data on 215 voit (line to line), 75 Hz, four - pole,…
A:
Q: EENG 342 – Second Semester 2020/2021 - Final Test Q1. The power consumption of a factory is 250 kVA…
A:
Q: a) For a liquid transformer oil system, the oil has relative dielectric constant ɛ = 3.35, density p…
A: Answer : (a) Given that εr=3.35ρ=2.59 g/cm3μ=3.62×10-5 cm2/V-sVb=680Vd=2.45 cm Although formula…
Q: A 3.5-MVA, Y-connected alternator rated at 4160 volts at 50-Hz has the open circuit characteristic…
A:
Q: Two turbo alternators with ratings given below are interconnected via a short transmission line.…
A: Given: Machine 1:f=50 HzP=4Moment of InertiaJ1=30000 kg-m2As we know, N=120fPN=120×504N=1500…
Q: phase, KV, 50 Hz, 900 km long line is operating with VS =VR = V = 1.0 p.u. and 8 = 60°. A SVC is…
A: length of line =l= 900 km Xs =0.05 pu V=1 pu
Q: A simple power system is shown in this Fig. The generator (480 V, 10 kVA) is connected to an ideal…
A: The transformer is a static device that steps up or steps down the voltage depending upon the turn…
Q: R, R. ら() R, R. Fig. Equivalent Circuit of IM Three phase, four pole, 45 Hz IM is obtained to be…
A: 3 phase, 4 pole, 45Hz, IM is obtained to be operating at a speed of 1250r/min with an input power of…
Q: 3-ph, 15 KVA, 220 V, Y-conn., 6-pole salient pole synchronous generator has open-circuit, short…
A: “Since you have posted a question with multiple sub-parts, we will solve the first three subparts…
Q: A simple power system is shown in this Fig. The generator (230 V, 20 kVA) is connected to an ideal…
A: In this question we need to calculate the load impedance in perunit for the given base value. Dear…
Q: Q5/A/ Calculate the maximum and minimum current in this conditions.(1- have maximum tran smission,…
A: 1. For maximum transmission, Transmission line should be matched. So for matched transmission line…
Q: The wind turbine gives the following data: Blade length, l = 49 m, Wind speed, V= 32 Km/Hr, Air…
A:
Q: The fuel-cost curves for a two generators power system are given as follows: C (P1) = 600 + 15 · P1…
A: Given: C1P1=600+15P1+0.05P12C2P2=700+20P2+0.04P22PL=2×10-4P12+3×10-4P22-4×10-4P1P2 MWMarginal cost,…
Q: - An electrical motor is modelled as 5117j ohm. Then a 300pF capacior is conneeted în parallel. If…
A:
Q: Q1: If the 2-stage Marx impulse generator circuit shown below is supplied by a DC voltage source of…
A: Since we only answer up to 3 sub-parts, we’ll answer the first 3. Please resubmit the question and…
Q: Q1 (a) A high voltage 3 phase induction motor operating at rated power can be represented by a…
A:
Q: A simple power system is shown in this Fig. The generator (480 V, 10 kVA) is connected to an ideal…
A: The transformer is a static device that steps up or steps down the voltage depending upon the turn…
Q: -than time constant of prime mover system. D. much greater 1. Time constant of excitation system is…
A: As per the guidelines given to us we can only provide the solution of three subpart in multi part…
Q: Question 26 What is the rise time for the system response shown? 30 Set point 10 10 20 30 40 50 60…
A: From given response we will find out time for 90% and 10% .
Q: R1/A 34, 4 Pole, 320 V, 50 Hz IM, the motor line Current of 40 Amp and o.8 observed when the motor…
A: multiple questions As per our guidlines we are supposed to do the first question if a student asks…
Q: wo turbo alternators with ratings given below are interconnected via a short transmission line.…
A: For the above-given data Inertia constant is determined as shown below
Q: Q22. Class A chopper is supplying a DC motor with FWD, motor inductance= 6 H & resistance- 12 SN,…
A: a) The maximum value of the load current is equal to : Imax.=VSR1-e-tONτ1+eTτ-ERVs=220 v ,E=5V,…
Q: 3-ph, 15 KVA, 220 V, Y-conn., 6-pole salient pole synchronous generator has open-circuit, short…
A: An alternator/Synchronous generator is a type of electrical machine that converts mechanical energy…
Q: In a power system, the present installed capacity is 2000MW. The peak demand is 18OOMW. The annual…
A: This question is from the "Generation" unit of "Power System". Under which we are going to study the…
Q: A 3-phase, Y-connected, 6-pole, 60HZ generator has X S=12, negligible rs (stator resistance), and…
A:
Q: 0.5 Consider the system given by Fig. 1. Where G,(s)=, 200s² +30s +1 Determine Routh stability of…
A: The given control system have unity feedback system. Determine the system is stable or not using…
Q: Problem: a. 30 500 KVA, diesel-engine generator, 50HZ its mechanical angle 60° coil pitch angle…
A:
Q: 1. Consider a composite load, powered from a 208 Vms ac line, that consists of the following four…
A: Calculate the real and reactive power delivered to load 1. PL1=5000 WQL1=0 VAR
Q: a. 30 500 KVA, diesel-engine generator, 50HZ its mechanical angle 60 coil pitch angle =140 and its…
A: Solution- a) Pitch angle = 140° chording angle = 180-140 = 40° KP = cosε/2 = cos20° =0.939 β…
Q: A two pole induction motor is to be used to drive a very heavy mixer in the cement industry. Three…
A: Hello. Since your question has multiple sub-parts, we will solve first three sub-parts for you. If…
Q: A 3Ø, 2000KW, 480V A-connected alternator is short-circuited and is operated at rated speed to…
A: Given data, No. of phase(ϕ)=3 Power(P3ϕ)=2000kW Voltage(VLL)=480V Rated Current(Isc)=P3ϕ3×VLL
Q: For a 3 phase, 440 V, 50 Hz, induction motor, circle diagram is shown in Fig. 1. Length of different…
A: As given the circle diagram of induction motor First we should know what length of line segments…
Q: Q5/A/ Calculate the maximum and minimum current in this conditions.(1- have maximum transmission, 2-…
A: 1. Have maximum transmission.For maximum transmission. transmission line sholud be matched. for…
Q: Stery readings, calculate the complex impedance of the mystery component. Where X and Y are the last…
A:
Q: An alternator stator winding protected by a percentage differential relay is shown in Fig. 1.12.8…
A:
Q: single phase motor operating off a 400V, 50Hz supply is developing 10KW with an efficiency of 84%…
A:
Q: A 3-phase, 3300 V, star-connected, synchronous motor has an effective resistance and synchronous…
A:
Q: (b) Draw open and short circuit characteristics using the following data for 13kV ,150 MW,0.8 pf…
A: Note: We are authorized to answer three subparts at a time since you have not mentioned which part…
Q: Q17. Find out the bus admittance matrix [Ybus] of the power system as shown in Fig.below.Data of the…
A:
Q: 1. A d.c. shunt generator running at 850 r.p.m. gave the followig 0.C.C. data : Field current (A) :…
A:
Q: 2. A 3Ø, 2000KW, 480V ∆-connected alternator is short-circuited and is operated at rated speed to…
A: Star connection is used for long distance transfer the power . In star connection the power 3 phase…
Q: - An eleAical motor īs modelled as 5117j ohm. Then a 300pF capacitor is conneeted în parallel. If…
A:
Q: 1. A three-phase induction motor delivers 100 hp while operating at an 80 percent efficiency and a…
A:
Q: A simple power system is shown in this Fig. The generator (480 V, 10 kVA) is connected to an ideal…
A:
Q: A simple power system is shown in this Fig. The generator (480 V, 10 kVA) is connected to an ideal…
A:
Q: ine 201 j60 N Zine 480 0° V
A: None of the given OPTIONS is correct
Q: 6. A single-phase AC/AC voltage controller is shown in Fig. 10, inductive load, R=6n, x, = 82,…
A: Figure shows two thyristor connected with a resistance and inductor having its own value. Delay…
Step by step
Solved in 3 steps with 3 images
- Two turbo alternators with ratings given below are interconnected via a short transmission line.Machine 1: 4 pole, 50Hz, 60MW, power factor 0.8 lagging, moment of inertia 30000 kg-m2Machine 2 : 2 pole, 50Hz, 80MW, power factor 0.85 lagging, moment of inertia 10,000kg-m2Calculate the inertia constant of the single equivalent machine on a base of 200MVA.A 4400V, 3-ph, Y- connected synchronous motor has an effective resistance and synchronous reactance of 3Ω and 19Ω per phase respectively. If the open–circuit generated emf is 4800V between lines, calculate The current .........amper *P.F at Maximum mechanical powerTotal Cu losses.........watt *Input power to motorA 6-phase ∆-connected 1600 V (line-to-line), 150 kW, 50 Hz, six-pole induction driveis used in an electric car. The drive has the following parameter values in Ω/phasereferred to the stator:R1 =0.334 Ω R2 =0.168 Ω Rm1 = 125 ΩX1 = 0.273 Ω X2 = 0.287 Ω Xm1 = 16.78 ΩThe total friction, windage, and core losses may be assumed to be constant at Prot =773 W, independent of load. For a slip value of s=0.015: b ) Compute the speed, output torque, power and stator current d) Calculate the efficiency when the motor is operated at rated voltage andfrequency. answer:b) n= 985 rpm; Torque T= 1.18 x104 Nm; Power= 1.22 x106 W; Stator current I = 175.72 /32.79° (d) Efficiency = 86.4%
- A 3Ø, Y-connected alternator is rated at 1,600KVA, 13.5KV. The armature effective AC resistance per phase is 1.5Ω. The percentage regulation for a load of 1,280kW at unity power factor is 3.5%. Determine:(a) synchronous reactance of the alternator(b) %VR at full-load 0.8pf leading(c) What is the effect on %VR value if taken at half-load lagging pf? Justify andexplain briefly your answer on one(1) sentence.A simple power system is shown in this Fig. The generator (480 V, 10 kVA) is connected to an ideal step-up transformer (1:10), a transmission line (R=20 Ohm and X=60 Ohm), step down transformer (20:1) and a load with magnitude Z=10 Ohm and angle =30 degree the base values for this system are chosen to be 480 V and 10 kVA at the generator. Calculate the per-unit impedance of the load. Select one: a. 1736 (45 degree) Ohm b. 36 (90 degree) Ohm c. 1.736 (30 degree) Ohm d. None of the aboveElectrical Engineering A wye-connected synchronous motor connected to a 440V, 3-phase line is operating with an electrical load (torque) angle of -28 degrees while demanding 90 kW from the mains. The motor has negligible resistance and reactance of 1.5 Ω/ph. Calculate: (a) The line-to-neutral excitation voltage (b) The line current and power factor.
- 1)For the following control system, use the Routh-Hurwitz criterion to determine if it is stable.If it is unstable, state the number of poles in the RHP, LHP and on the jwaxis R(s)—% 1 ‘ Ts(2s'+3s°+ 257 + 35 + 2) Y(s)An electrical motor is supplied from a three-phase ,50 Hz, 410 V system on-board a LNG carrier .When connected in star , it takes a line current of 35 A at a power factor of 0.66 leading. The LNG carrier arrives at port and the motor is subsequently used for powering a container crane It is now connected in delta and is supplied on-shore .Determine for this motor when it takes 64 A at 310 V, from the on-shore supply: 2.1 The power factor of the motor 2.2 the frequency of the supply The motor is returned back to its initial supply and now connected with a new motor in parallel . The new motor is connected in delta and it takes 48.216 kVA at a power factor of 0.77597 lagging with a supply of 50 Hz, 410 V system. Determine for this new arrangement : 2.3 The power factor 2.4 Apparent power taken 2.5 True power taken 2.6 Reactive power takenA stator impedance and equivalent rotor resistance of a 40 , 3-phase star-connected inductionmotor are (0.06 + j0.2) ohms and equivalent rotor impedance (0.06 + j0.2) ohms Neglect exciting current,Find the max gross power and the slip at which it occurs.
- a) What applications / experiments are necessary to find the Rc parameter in the equivalent circuit given in Figure 1? b) Write the value of the Ir 'current given in Figure 1 with a sentence in the idle running test of the 3-phase Asynchronous motor.A 19 kVA, 419 V, 50-Hz, 3-φ, star-connected synchronous generator gave the following test data : Field current (A): 2 4 6 7 8 10 12 14 Terminal volts: 155 287 395 440 475 530 570 592 S.C. current : 11 22 34 40 46 57 69 80 Resistance between any two terminals is 0.3 Ω Find regulation at full-load 0.8 p.f. lagging by synchronous impedance method. Take ZS corresponding to S.C. current of 80 A.Assume that a feeder supplier an industrial consumerwith a cumulative load of: (i) induction motors totaling300 hp which run at an average efficiency of 89% and alagging average power factor of 0.85, (ii) synchronousmotors totaling 100 hp with an average efficiency of86%, and (iii) a heating load of 100 kW as shown in Fig.1. The industrial consumer plans to use thesynchronous motors to correct its overall power factor.Determine the required power factor of thesynchronous motors to correct the overall power factorat peak load to: (a). Unity and (b). 0.96 lagging