The following information is given for a 320KW 600V long shunt flat compound generator, when the machine delivering rated load: RA 0.0262, RF -80Ω, Rs 0.0152, Rp = 0.0382 and the commutating field winding resistance Rc = 0.0122. Calculate the Induced voltage and Power generated by the armature.
Q: The following information is given for a 300-kW, 600-V, short-shunt compound generator : Shunt field…
A:
Q: Q3) In a long-shunt compund generator, the terminal voltage is 230 V, when it delivers 150 A. The…
A: This question belongs to electrical machine . It is based on the concept of dc generator . Have a…
Q: A 100-MVA 12.5-kV 0.85-PF-lagging 50-Hz two-pole Y-connected synchronous generator has a per-unit…
A: Impedance in ohms = per unit impedance × base impedance. Internal induced voltage= terminal…
Q: A 220V short-shunt compound generator has armature resistance, series field resistance and shunt…
A:
Q: A 90-MVA 69.3-kV, three-phase synchronous generator has a synchronous reactance of 10 Ohms/phase and…
A: In this question we need to find power delivered by genrator , armature current and power factor
Q: 3. A three phase, 50 Hz, 4800V, 6 pole Y-connected synchronous generator connected to an infinite…
A: Since you posted the multiple questions. So I am solve first 3 questions for you
Q: In a long-shunt compound generator, the terminal voltage is 220 V when generator delivers 110 A.…
A: According to question diagram would be, Given parameters: V=220 VI= 110 ARsh=90 ΩRse=0.025ΩRd=0.04…
Q: A Short shunt compound generator delivers a load current of (16)A at 400V. Armature resistance 0.08…
A:
Q: LA 480-V, 60-Hz, A-connected, four-pole synchronous generator. This generator has an armature…
A:
Q: Q: In a long-shunt compound generator, the terminal voltage is 220 V when generator delivers 500 A.…
A: Given Data: Vt = 220 V IL = 500 A Rsh = 110 ohm Rse = 0.002 ohm Ra = 0.01 ohm
Q: Q3\ In a long-shunt compund generator, the terminal voltage is 230 V, when it delivers 150 A. The…
A:
Q: A 3 phase 1.2 MVA, 10 kV star connected synchronous generator has Zs= 0.2+J10 ohm. Using circle…
A: Synchronous Generators, often known as alternators, are the most commonly used generators for…
Q: A 70-MVA, 69.3-kV, three-phase round-rotor synchronous generator has a synchronous reactance of 14…
A: (1) KVL equation to the above system Given rating of the machine is 70MVA power factor 0.87lag…
Q: A 240-V, short-shunt, cumulative compound generator is rated at 100 A The shunt field current is 3…
A: Efficiency: It tells that how much input power in applied to the machine and how much power is…
Q: ) A 50 MVA, 30 kV, three-phase, 50 Hz synchronous generator have a synchronous reactance of 9 Q per…
A:
Q: The terminal voltage of a 75-kW shunt generator is 600 V at rated load. The resistance of the…
A: NOTE: “Since you have asked multiple question, we will solve the first question for you. If you want…
Q: Question 3: A 3-phase, 11 kV, 10 MVA synchronous generator is connected to a load that has a power…
A: An alternator/Synchronous generator is a type of electrical machine that converts mechanical energy…
Q: Q3) In a long-shunt compund generator, the terminal voltage is 230 V, when it delivers 150 A. The…
A:
Q: A 480-V, 60-Hz, Y-Connected synchronous generator, having the synchronous reactance of 1.04 ohm and…
A: Generator is a device to convert a mechanical energy to electrical energy. It is work on the…
Q: A 12 KW shunt generator having an armature circuit resistance of 0.8 Ω and a field resistance of 120…
A: The solution can be achieved as follows.
Q: A 3 phase 1.2 MVA, 10 kV star connected synchronous generator has Zs= 0.2+J10 ohm. Using circle…
A: A Synchronous Generator is also known as the alternator, the most widely used generator for power…
Q: |--E Q3) In a long-shunt compund generator, the terminal voltage is 230 V, when it delivers 150 A.…
A:
Q: Problem: A 30 kW, 250 volts shunt generator is overloaded by 30% by maintaining its emf at rated…
A:
Q: A short shunt cumulative compound dc generator supplies 6kW at 235V. The Shunt field resistance,…
A:
Q: A three-phase, Y-connected, 220 V, 5 kVA, salient-pole synchronous generator is employed to supply…
A: Given information about a three-phase Y-connected salient-pole synchronous generator is: Rated…
Q: A short-shunt compound generator delivers a load current of 30 A at 220 V and has armature,…
A: Given Armature resistance = 0.04Ω series-field resistance = 0.2Ω Shunt field resistance = 100Ω Per…
Q: Q3) In a long-shunt compund generator, the terminal voltage is 230 V, when it delivers 150 A. The…
A:
Q: Q3 In a long-shunt compund generator, the terminal voltage is 230 V, when it delivers 150 A. The…
A:
Q: A 480-V, 50-Hz, Y -connected, six-pole synchronous generator has a per-phase synchronous reactance…
A: Given star connected 6-pole synchronous generator, Voltage 480v Synchronous reactance 1.0H Armature…
Q: A 220V, 5.5 kW, DC shunt generator has an armature resistance of 0.2 Q and a total field-circuit…
A: Given A dc shunt motor with specifications.we need to find the voltage regulation. Please find the…
Q: A 90-MVA 69.3-KV, three-phase synchronous generator has a synchronous reactance of 11 Ohms/phase and…
A: In this question we need to find a power delivered by genrator, armature current and power factor
Q: A three-phase, 12-kV, 60 Hz, 6 pole wye connected synchronous generator has synchronous reactance of…
A: Given values are - Vt=12kVf=60HzP=6XS=15OhmEA=13kV
Q: A three phase, 50 Hz, 4800V, 6 pole Y-connected synchronous generator connected to an infinite bus…
A: from given electrical power output we will find out the Excitation voltage. From excitation voltage…
Q: Q1. The per-unit d-axis and g-axis reactance's of a salient-pole generator are 0.9 and 0.6…
A:
Q: A 20 kW, 440-V, short-shunt, compound d.c. generator has a full-loade fficiency of 87%. If the…
A: Given:P=20kWVt=440Vshort shunt compound DC generator87% efficiencyRa=0.4ΩRs=0.25ΩRsh=240Ω
Q: Explain the conditions for parallel operation of synchronous generators. A three phase, wye…
A: An alternator/Synchronous generator is a type of electrical machine that converts mechanical energy…
Q: Problem: The field current of a 100-kW, 250V shunt generator is 5A when delivering power at rated…
A: DC machines (Generator/ Motor) are the important parts of electrical drives. These machines are used…
Q: A 20 kW, 440-V, short-shunt, compound d.c. generator has a full-load efficiency of 87%. If the…
A: In this question, A 20 kW, 440-V, short shunt, compound d.c. generator has a full load efficiency of…
Q: 11. A 20 kW, 440-V, short-shunt, compound d.c. generator has a full-load efficiency of 87%. If the…
A: As per our guidelines we have to solve 1st question So, solution for 1 st question is below.…
Q: Q21) A 5-k VA, 220-V, Y-connected, three-phase, salient-pole synchronous generator is used to supply…
A: Note:- As per our guidelines we are supposed to answer?️ only one question. Kindly repost other…
Q: A shunt generator supplies a 31kW load at 230V through cables of resistance, R = 122mΩ. If the…
A: In this question we need to find a terminal Voltage and internal emf genrated by Shunt Genrator.
Q: A 440 V, 3-phase, delta connected cylindrical synchronous motor with synchronous reactance of…
A: Since we only answer up to 3 sub-parts, we’ll answer the first 3. Please resubmit the question and…
Q: Q1/ The following information is given for a 250-kW, 500-V, long-shunt compound generator: Shunt…
A: Given, the power output is 250 kW The voltage is 500 V.
Q: A short-shunt generator supplies 220A at 260V. The armature resistance is 0.15Ω, shunt field…
A:
Q: A 150-kW 250-volt compound generator is connected long shunt. If the shunt field resistance is 20…
A: On each pole of a compound wound generator, there are two sets of the field winding. With the…
Q: A 4 pole DC shunt generator with wave wound armature having 383 conductors, has to supply a load of…
A: we will use KVL and KCL to find the armature current and generated EMF . From generated EMF we will…
Q: A three phase, 50 Hz, 4800V, 6 pole Y-connected synchronous generator connected to an infinite bus…
A: I think there is no concept of output torque. there are two torques, one is shaft torque and other…
Q: A 10kW, 125V long shunt compound generator has rotational losses amounting to 580W. The motor…
A: In this question we need to find a armature genrated voltage and efficiency at full load.
number 2
Step by step
Solved in 2 steps with 1 images
- A 4-quadrant DC chopper with bipolar switching operating at a switching frequency of 2kHz, is connected to a 120VDC source (Vs) and a DC motor which has a counter EMF (CEMF) of 50VDC at rated speed. The armature resistance is 2Ω and the armature inductance is 20mH. Calculate: a) Output voltage with an 80% duty cycle b) Magnitude and direction of the DC armature current with an 80% duty cycle. c) Duty cycle for a forward braking current of 10ADC. (Assume the speed has not changed due to the large inertia of the load.)A shunt generator supplies a 30kW load at 215V through cables of resistance, R = 110mn. If the field winding resistance, Rf =680 and the armature resistance, Ra =45mn. Determine the following below: The terminal voltage is, The e.m.f. generated in the armature is,Suppose a shunt regulator voltage is 250V, the armature current is 30A. field coils are required to provide an MMF of 500AT. The field might typically say 200turns with resistance of 0.5Ohms/turn. Find the dissipated power as heat and total input required and the efficiency
- analyze 3 commonly used ac motor starting methods using suitable diagrams and torque-speed curvesA separately excited motor runs at 1045rpm, with a constant field current, while taking an armature current of 50A at 120V. The armature resistance is 0.1 Ω if the load on the motor changes such that it now takes 95A at 120V, determine the motor speed at this load.The armature, series field and shunt field resistances of a 125kW, 250V long shunt cumulative compound dc generator are 0.025-ohm, 0.01 ohm and 30 ohms, respectively. If the stray power loss at rated load is 5kW, determine the motor brake horsepower required to drive this machine. Assume a brush drop of 2V and a stray load loss of 1% of the output.
- A separately excited generator has no-load voltage of 125V. A certain load rated at 1200W, 120V is then connected at the terminal. Calculate the series resistance needed to connect to the armature circuit in order for the load to operate at rated condition if the armature resistance is 0.0692Ω.Explain the concept of motherboard power delivery and voltage regulation. How does the quality of power delivery components (e.g., VRMs) impact the stability and overclocking potential of a system?[Electrical Machines and Power System] Discuss two design considerations when selecting a stepper motor.
- Describe the merits of buckhholz relayA 110V shunt generator has a full load current of 100A, shunt field resistance of 55 ohms and constant losses of 500W. If full load efficiency is 88%, find the armature resistance. Assuming voltage to be constant at 110V, calculate the efficiency at half load. Find the load current.Describe the main advantage of GTO over thyristor.