MindTap Engineering for Glover/Overbye/Sarma's Power System Analysis and Design, 6th Edition, [Instant Access], 1 term (6 months)
6th Edition
ISBN: 9781305636309
Author: J. Duncan Glover; Thomas Overbye; Mulukutla S. Sarma
Publisher: Cengage Learning US
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 10, Problem 10.4P
(a)
To determine
The value of Vab, Vbc, and Vca for the dots are shown in Figure 10.38.
(b)
To determine
The value Vab, Vbc, and Vca for the dot near c is moved to b in Figure 10.38.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
128, An equipment has an impedance 0.9 p.u. to a
base of 20 MVA, 33 kV. To the base of 50 MVA,
11 kV, the p.u. impedance will be
(a) 4.7
(c) 0.9
(b) 20.25
(d) 6.75
Can I have help with problem 9.9?
Can we improve a leading load pf using a synchronous condenser? Explain briefly your answerin one(1) sentence.
Chapter 10 Solutions
MindTap Engineering for Glover/Overbye/Sarma's Power System Analysis and Design, 6th Edition, [Instant Access], 1 term (6 months)
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, computer-science and related others by exploring similar questions and additional content below.Similar questions
- How did 2 + j8ohms become 2 + 2 + j8ohms and then 8.9 ∠63.4? Like what did you do and why?arrow_forwardTwo 240V fluorescent lighting units are arranged to minimize the stroboscopic effect. The active and reactive current components of the unit 1 are 0.6A and 0.2A respectively. The active and reactive current components of the unit 2 are 0.3A and 0.6A respectively. Determine the value of total current consumed by the two units. A-Final active current component is B-Final reactive current component is C-Total current consumed by the two units arearrow_forward2. When a large shunt capacitor is suddenly connected in parallel with the load bus in the distribution feeder, what would happen to this bus current? O A. Increase B. Decrease D. None of Abovearrow_forward
- 10. A three-phase transformer consists of a bank of single-phase transformers connected to form a Dd0 connection. A fault on one of the transformers causes it to be removed from the circuit, and the remaining two transformers are connected in an open-delta (V-V) connection. Show that the capacity of the open-delta connected transformers is 58% of the delta-connected transformers.arrow_forwardCalculate the initial symmetrical short circuit current that will occur when a 3 phase short circuit error occurs at the F point in the Figure below İ k3 phase-max ?arrow_forwardWhat is the difference between OLTC and transformersarrow_forward
- Description In the particular case of figure below derive both the critical clearing angle and the critical clearing time. P, = Pmaz sin d Pm A1 do der Smar A generator having H = 6.R MJ/MVA is delivering power of 1.0 per unit to an infinite bus through a purely reactive network when the occurrence of a fault reduces the generator output power to zero. The maximum power that could be delivered is 2.5S per unit. When the fault is cleared, the original network conditions again exist. Determine the critical clearing angle and critical clearing time. (Roll=PQRS)arrow_forwardThe one-line diagram of a simple three-bus power system is shown in Figure 9.1. Each generator is represented by an emf behind the transient reactance. All impedances are expressed in per unit on a common 100 MVA base, and for sim- plicity, resistances are neglected. The following assumptions are made. (i) Shunt capacitances are neglected and the system is considered on no-load. (ii) All generators are running at their rated voltage and rated frequency with their emfs in phase. Determine the fault current, the bus voltages, and the line currents during the fault when a balanced three-phase fault with a fault impedance Zf = 0.16 per unit %3D occurs on Bus 3.arrow_forwardA power station consists of two synchronous generators A & B of ratings 250 MVA and 500MVA with inertia 1.6 pu and 1.0 pu respectively on their own base MVA ratings. The equivalent pu inertia constant for the system on 100 MVA common base is:- (a) 2.6 (b) 0.615 (c) 1.625 (d) 9.0arrow_forward
- The figure below shows the one-line diagram of a four- bus power system. The voltages, the scheduled real power and reactive powers, and the reactances of transmission lines are marked at this one line diagram (The voltages and reactances are in PU referred to 100 MW base. The active power P2 in MW is the last three digits (from right) of your registration number (i.e for the student that has a registration number 202112396, P2 =396). [10] Starting from an estimated voltage at bus 2, bus 3, and bus 4 equals V2 (0) = 1.15<0°, V3 = 1.15 < 0°, V4 1.1< 0°. 1- Specify the type of each bus and known & unknown quantities at each bus. 2- Find the elements of the second row of the admittance matrix (i.e. [Y21 Y22 Y23 Y24]). 3- Using Gauss-Siedal fınd the voltage at bus 2 after the first iteration. 4- Using Newton-Raphson, calculate: |- The value of real power (P2), at bus 2 after the first iteration. Il- The second element in the first row of the Jacobian matrix after the first iteration. 2 P2…arrow_forwardIn the following network, the voltage magnitudes at all buses are equal to 1 p.u., the voltage phase angles are very small, and the line resistances are negligible. All the line reactances are equal to j1 p.u. (1) (2. P₂ = 0.1 p.u. P3 = 0.2 p.u. The voltage phase angle 83 in radian at bus 3 is (Assume one of the generator bus as slack bus and sin-¹ (0.1) = 0.1 rad) (a) -0.1 (b) -0.2 (c) 0.1 (d) 0arrow_forwardIn the T-Model method which among these are divided into two halves. a. Both (A) and (B) b. None of these c. Shunt capacitance d. Series impedancearrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Introductory Circuit Analysis (13th Edition)Electrical EngineeringISBN:9780133923605Author:Robert L. BoylestadPublisher:PEARSONDelmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage LearningProgrammable Logic ControllersElectrical EngineeringISBN:9780073373843Author:Frank D. PetruzellaPublisher:McGraw-Hill Education
- Fundamentals of Electric CircuitsElectrical EngineeringISBN:9780078028229Author:Charles K Alexander, Matthew SadikuPublisher:McGraw-Hill EducationElectric Circuits. (11th Edition)Electrical EngineeringISBN:9780134746968Author:James W. Nilsson, Susan RiedelPublisher:PEARSONEngineering ElectromagneticsElectrical EngineeringISBN:9780078028151Author:Hayt, William H. (william Hart), Jr, BUCK, John A.Publisher:Mcgraw-hill Education,
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:PEARSON
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning
Programmable Logic Controllers
Electrical Engineering
ISBN:9780073373843
Author:Frank D. Petruzella
Publisher:McGraw-Hill Education
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:9780078028229
Author:Charles K Alexander, Matthew Sadiku
Publisher:McGraw-Hill Education
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:9780134746968
Author:James W. Nilsson, Susan Riedel
Publisher:PEARSON
Engineering Electromagnetics
Electrical Engineering
ISBN:9780078028151
Author:Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:Mcgraw-hill Education,