Chapter 11, Problem 11.10QAP
Interpretation Introduction
Interpretation:
The reason of using internal standards in the quantitative analysis by ICPMS needs to be explained.
Concept introduction:
ICPMS i.e. Inductively Coupled Plasma Mass Spectrometry carries out quantitative analysis at micro concentrations. To maintain the precision and accuracy, it is essential to eliminate or compensate for all possible errors.
To neutralize the systemic random errors, it is mandatory to test an internal standard.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
What are the advantages and disadvantages of volumetric and gravimetric analysis?
(a) For use in an iodine titration, you prepare a solution from 0.222 2 (+0.000 2) g of KIO3 [FM 214.001 0 (+0.000 9)] in 50.00 (+0.05) mL. Find the molarity and its uncertainty with an appropriate number of significant figures. (b) Would your answer be affected significantly if the reagent were only 99.9% pure?
Analytical chemistry is a particular field within the broader spectrum of the chemical sciences, in which many times the focus of analytical experiments is to develop new methods to analyze compounds, either structurally or by determining concentrations of compounds. One of the processes analytical chemists use to determine the exact concentration of a working solution is called standardization. In your own words, describe the differences between a primary, secondary, and tertiary standard, and describe the underlying concept behind the standardization process. Why is it done?
Chapter 11 Solutions
PRINCIPLES OF INSTRUMENTAL ANALYSIS
Knowledge Booster
Similar questions
- A volumetric calcium analysis on triplicate samples of the blood serum of a patient believed to be suffering from a hyperparathyroid condition produced the following data: mmol Ca/L = 3.15, 3.25, 3.26. What is the 95% confidence interval for the mean of the data, assuming no prior information about the precision of the analysis?arrow_forwardYou are preparing a 100.0 mL standard solution needed for titration analysis. The NaOH (40 g/mol) pellets are measured to be 0.5341 g in a balance with acceptable uncertainty of +0.001 g. Mass of the pellets is recorded after taring the container. The pellets are put in a beaker and added with 50 ml distilled water measured by a graduated cylinder. The solution is then quantitatively transferred to a 100-mL volumetric flask with uncertainty of ±0.08 mL and diluted to a 100-mL mark. What is the concentration (M) of the solution and estimate its uncertainty by propagation? Assumption: There is no uncertainty in molar mass. Express your answer as C+/- u M.arrow_forwardA titrimetric method for the determination of calcium in limestone was tested with the analysis of a NIST limestone containing 30.15% CaO. The mean of the four analyzes is 30.26% CaO with a standard deviation of 0.085%. From the data accumulated from many analyzes, s→ϭ=0.094% CaO was found.a) Do the data indicate the presence of systematic error at the 95% confidence level?b) When a value for ϭ is unknown, do the data show a systematic error at the 95% confidence level?arrow_forward
- A volumetric calcium analysis on triplicate samples of the blood serum of a patient believed to be suffering from a hyperparathyroid condition produced the following data: mmol Ca/L = 3.55, 3.65, 3.14. What is the 95% confidence interval for the mean of the data, assuming(a) No prior information about the precision of the analysis?(b) s → σ = 0.056 mmol Ca/L?arrow_forwardWhat are the advantages and disadvantages of using external standards in instrumental analysis?arrow_forwardA titrimetric method for the determination of calcium in limestone was tested by analysis of an NIST limestone containing 30.15% CaO. The mean result of four analyses was 30.26% CaO, with a standard deviation of 0.085%. By pooling data from several analyses, it was established that s = 0.094% CaO.a. Do the data indicate the presence of a systematic error at the 95% confidence level?b. Do the data indicate the presence of systematic error at the 95% confidence level if no pooled value for s was available?arrow_forward
- professor Scimemi has accepted you as a Master’s student and you are involved in a project that studies the cellular basis of neuropsychiatric diseases. For your electrophysiology recordings you have to make a recording solution containing (in mM): 119 NaCl, 2.5 KCl, 2.5 CaCl2, 1 MgCl2, 26.2 NaHCO3, 1 NaH2PO4, 22 glucose. You need 800 ml of it. How much KCl do you need to weigh out? Hint: we only care about KCl here. (MW KCl is 74.55 g/molarrow_forwardWhat is the purpose of a calibration curve in analytical chemistry?arrow_forwardThe analysis shows different concentrations based on replicate determinations of Zn in a water sample: 0.754 mg, 0.721 mg, 0.734 mg, 0.731 mg and 0.742 mg. What is the absolute error if the standard solution has 0.750 mg of Zn?arrow_forward
- (3) In a titration, the % analyte is computed from the following equation: Vol (titrant) x M (titrant) x MW (analyte) % analyte = x 100 Weight (sample) Calculate the absolute error in the % analyte from the following data. Vol (titrant)= 38.04 t 0.02 ml M (titrant) MW (analyte) = 74.116 t 0.005 mg/mmol Wt (sample) = 800.0 ± 0.2 mg = 0.1137 ± 0.0003 mmol/ml %3!arrow_forwardList and define the indicators that are used to assess the performance of a specific analytical method under specified conditions.arrow_forwardWhat is the actual or real-life application of precipitation gravimetric analysis? Include the specific methodology.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning