Question
Chapter 11.10, Problem 81P
To determine
Why are the fluid in the absorber cooled and the fluid in the generator heated in an absorption refrigeration system.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
I only need help with letter (e).
In a vapor-compression refrigeration cycle, ammonia exits the evaporator as saturated vapor at -22°C. The refrigerant enters the condenser at 16 bar and 190°C, and saturated liquid exits at 16 bar. There is no significant heat transfer between the compressor and its surroundings, and the refrigerant passes through the evaporator with a negligible change in pressure.If the refrigerating capacity is 50 kW, determine:(a) the mass flow rate of the refrigerant, in kg/s.(b) the power input to the compressor, in kW.(c) the coefficient of performance.(d) the isentropic compressor efficiency, in percent.(e) the rate of entropy production, in kW/K, for the compressor.
An ideal vapor-compression refrigeration cycle, with refrigerant R-22 as the working fluid, has an evaporator temperature of -12°C and a condenser pressure of 14 bar. The saturated vapor enters the compressor, and the saturated liquid exits the condenser. The refrigerating capacity is 14 tons.
Determine:
a) the mass flow rate of the refrigerant, in kg/min.b) the compressor power, in kW.c) the coefficient of performance
A vapor compression refrigeration system operates on the cycle shown below (from Smith, Van Ness, and Abbott text). The refrigerant is tetrafluoroethane (P-H diagram from Smith, Van Ness, and Abbott text on next page). Determine the circulation rate of the refrigerant (in kg/s), the heat transfer rate in the condenser (in kW), the actual power requirement from compressor (in kW), the overall coefficient of performance of the cycle, and the coefficient of performance of a Carnot refrigeration cycle operating between the same temperature levels. Use the following operating data: Evaporation T = -10°C; Condensation T = 26°C; Compressor Efficiency Factor = 0.8; Refrigeration rate = 500 kJ/s.
Chapter 11 Solutions
EBK THERMODYNAMICS: AN ENGINEERING APPR
Ch. 11.10 - Why is the reversed Carnot cycle executed within...Ch. 11.10 - Why do we study the reversed Carnot cycle even...Ch. 11.10 - 11–3 A steady-flow Carnot refrigeration cycle uses...Ch. 11.10 - Does the ideal vapor-compression refrigeration...Ch. 11.10 - Why is the throttling valve not replaced by an...Ch. 11.10 - It is proposed to use water instead of...Ch. 11.10 - In a refrigeration system, would you recommend...Ch. 11.10 - Does the area enclosed by the cycle on a T-s...Ch. 11.10 - Consider two vapor-compression refrigeration...Ch. 11.10 - The COP of vapor-compression refrigeration cycles...
Ch. 11.10 - An ice-making machine operates on the ideal...Ch. 11.10 - A 10-kW cooling load is to be served by operating...Ch. 11.10 - 11–13 An ideal vapor-compression refrigeration...Ch. 11.10 - 11–14 Consider a 300 kJ/min refrigeration system...Ch. 11.10 - 11–16 Repeat Prob. 11–14 assuming an isentropic...Ch. 11.10 - 11–17 Refrigerant-134a enters the compressor of a...Ch. 11.10 - A commercial refrigerator with refrigerant-134a as...Ch. 11.10 - 11–19 Refrigcrant-134a enters the compressor of a...Ch. 11.10 - A refrigerator uses refrigerant-134a as the...Ch. 11.10 - The manufacturer of an air conditioner claims a...Ch. 11.10 - Prob. 23PCh. 11.10 - How is the second-law efficiency of a refrigerator...Ch. 11.10 - Prob. 25PCh. 11.10 - Prob. 26PCh. 11.10 - Prob. 27PCh. 11.10 - 11–28 Bananas are to be cooled from 28°C to 12°C...Ch. 11.10 - A vapor-compression refrigeration system absorbs...Ch. 11.10 - A refrigerator operating on the vapor-compression...Ch. 11.10 - A room is kept at 5C by a vapor-compression...Ch. 11.10 - Prob. 32PCh. 11.10 - 11–33 A refrigeration system operates on the ideal...Ch. 11.10 - When selecting a refrigerant for a certain...Ch. 11.10 - Consider a refrigeration system using...Ch. 11.10 - A refrigerant-134a refrigerator is to maintain the...Ch. 11.10 - A refrigerator that operates on the ideal...Ch. 11.10 - A heat pump that operates on the ideal...Ch. 11.10 - Do you think a heat pump system will be more...Ch. 11.10 - What is a water-source heat pump? How does the COP...Ch. 11.10 - Prob. 42PCh. 11.10 - Refrigerant-134a enters the condenser of a...Ch. 11.10 - Prob. 45PCh. 11.10 - A heat pump using refrigerant-134a heats a house...Ch. 11.10 - How does the COP of a cascade refrigeration system...Ch. 11.10 - A certain application requires maintaining the...Ch. 11.10 - Consider a two-stage cascade refrigeration cycle...Ch. 11.10 - Can a vapor-compression refrigeration system with...Ch. 11.10 - Prob. 52PCh. 11.10 - Prob. 53PCh. 11.10 - Repeat Prob. 1156 for a flash chamber pressure of...Ch. 11.10 - Prob. 56PCh. 11.10 - Prob. 57PCh. 11.10 - 11–58 Consider a two-stage cascade refrigeration...Ch. 11.10 - Prob. 59PCh. 11.10 - A two-evaporator compression refrigeration system...Ch. 11.10 - A two-evaporator compression refrigeration system...Ch. 11.10 - Repeat Prob. 1163E if the 30 psia evaporator is to...Ch. 11.10 - How does the ideal gas refrigeration cycle differ...Ch. 11.10 - Devise a refrigeration cycle that works on the...Ch. 11.10 - How is the ideal gas refrigeration cycle modified...Ch. 11.10 - Prob. 66PCh. 11.10 - How do we achieve very low temperatures with gas...Ch. 11.10 - 11–68E Air enters the compressor of an ideal gas...Ch. 11.10 - Prob. 69PCh. 11.10 - Air enters the compressor of an ideal gas...Ch. 11.10 - Repeat Prob. 1173 for a compressor isentropic...Ch. 11.10 - Prob. 73PCh. 11.10 - Prob. 74PCh. 11.10 - Prob. 75PCh. 11.10 - A gas refrigeration system using air as the...Ch. 11.10 - An ideal gas refrigeration system with two stages...Ch. 11.10 - Prob. 78PCh. 11.10 - Prob. 79PCh. 11.10 - What are the advantages and disadvantages of...Ch. 11.10 - Prob. 81PCh. 11.10 - Prob. 82PCh. 11.10 - An absorption refrigeration system that receives...Ch. 11.10 - An absorption refrigeration system receives heat...Ch. 11.10 - Heat is supplied to an absorption refrigeration...Ch. 11.10 - Prob. 86PCh. 11.10 - Prob. 87PCh. 11.10 - Prob. 88PCh. 11.10 - Prob. 89PCh. 11.10 - Consider a circular copper wire formed by...Ch. 11.10 - An iron wire and a constantan wire are formed into...Ch. 11.10 - Prob. 92PCh. 11.10 - Prob. 93PCh. 11.10 - Prob. 94PCh. 11.10 - Prob. 95PCh. 11.10 - Prob. 96PCh. 11.10 - Prob. 97PCh. 11.10 - Prob. 98PCh. 11.10 - A thermoelectric cooler has a COP of 0.18, and the...Ch. 11.10 - Prob. 100PCh. 11.10 - Prob. 101PCh. 11.10 - Prob. 102PCh. 11.10 - Prob. 103RPCh. 11.10 - Prob. 104RPCh. 11.10 - Prob. 105RPCh. 11.10 - A heat pump that operates on the ideal...Ch. 11.10 - A large refrigeration plant is to be maintained at...Ch. 11.10 - Repeat Prob. 11112 assuming the compressor has an...Ch. 11.10 - A heat pump operates on the ideal...Ch. 11.10 - An air conditioner with refrigerant-134a as the...Ch. 11.10 - An air conditioner operates on the...Ch. 11.10 - Consider a two-stage compression refrigeration...Ch. 11.10 - A two-evaporator compression refrigeration system...Ch. 11.10 - Prob. 116RPCh. 11.10 - Prob. 117RPCh. 11.10 - Prob. 118RPCh. 11.10 - Consider a regenerative gas refrigeration cycle...Ch. 11.10 - Prob. 120RPCh. 11.10 - The refrigeration system of Fig. P11122 is another...Ch. 11.10 - Repeat Prob. 11122 if the heat exchanger provides...Ch. 11.10 - An ideal gas refrigeration system with three...Ch. 11.10 - Derive a relation for the COP of the two-stage...Ch. 11.10 - Prob. 129FEPCh. 11.10 - Prob. 130FEPCh. 11.10 - Prob. 131FEPCh. 11.10 - Prob. 132FEPCh. 11.10 - An ideal vapor-compression refrigeration cycle...Ch. 11.10 - Prob. 134FEPCh. 11.10 - An ideal gas refrigeration cycle using air as the...Ch. 11.10 - Prob. 136FEPCh. 11.10 - Prob. 137FEPCh. 11.10 - Prob. 138FEP
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Why is two-stage compression popular for extra-low-temperature refrigeration systems?arrow_forwardWhen the outside ambient air temperature is 90F, the temperature of the condensing refrigerant in a standard- efficiency unit should be approximately A. 120F. B. 130F. C. 140F. D. 150F.arrow_forwardCondensers in these refrigerators are all_______cooled.arrow_forward
- What is the common refrigerant used in absorption refrigeration machines?arrow_forward3) In a multistage vapor-compression refrigeration cycle, refrigerant 134a is the working fluid. Saturated vapor enters the first compressor stage at T, = -30°C. The flash chamber operates at 0.4MPA, and the condenser pressure is 1.2MPA. Saturated liquid streams at 1.2MPa and 0.4MP enter the high- and low-pressure expansion valves, respectively. If compressors are isentropic and QL = 35kW determine the coefficient of performance of the refrigeration system. Warm environment Condenser Expansion valve High-pressure compressor Flash chamber 1-0 Low-pressure Expansion valve compressor Evaporator Cold refrigerated spacearrow_forwardA refrigerator operating using vapor-compression cycle uses R-134a as a working fluid. The condenser temperature is 65oC and the evaporator temperature is -15oC. The compressor operates at 80% efficiency. a. Determine the coefficient of performance of the refrigeration cycle. b. How much refrigerant is needed to deliver 3 kW of cooling? c. Sketch the vapor compression cycle indicating the states of each stream (in terms of H, P, T, and S) and showing the values of energy input/output in the system d. Suppose that we replace the expansion valve in the vapor- compression cycle with a turbine that operates at 80% efficiency. Determine the coefficient of performance of the refrigeration cycle. Provide the new state properties (i.e. H, P, T and S) for this changes Please use CATT for any values neededarrow_forward
- Data for steady-state operation of a vapor-compression refrigeration cycle with Refrigerant 134a as theworking fluid are given in the table below. State 1 is at the compressor inlet. The cooling capacity (i.e therate at which heat is removed from the cooled space) is 4.6 tons. 1 ton of refrigeration is equivalent to211 kJ/min. Ignoring heat transfer between the compressor and its surroundings, sketch the ?-? diagramof the cycle and determinea) the mass flow rate of the refrigerant, in kg/min.b) the isentropic compressor efficiency.c) the coefficient of performance.State ? (bar) ? (°C) ℎ (kJ/kg) ? (kJ/kg-K)arrow_forwardA two-stage refrigerating system is operating between the pressure limits of 8 bar and 1.4 bar. The working fluid is R134a. The refrigerant leaves the condenser as a saturated liquid and is throttled to a flash chamber operating at 3.2 bar. The part of the refrigerant evaporates during the flashing process and this vapour is mixed with the refrigerant leaving the low-pressure compressor. The mixture is then compressed to the condenser pressure by the high-pressure compressor. The liquid in the flash chamber is throttled to the evaporator pressure and coolsthe refrigerated space as it evaporates in the evaporator. Assuming the refrigerant leaves the evaporator as a saturated vapour and both compressions are isentropic, determine (a) the fraction of the refrigerant that evaporates as it is throttled to the flash chamber,(b) the amount of heat removed from the refrigerated space and the compressor work per unit mass of refrigerant flowing through the condenser, and(c) the coefficient of…arrow_forwardConsider the ideal vapor compression cycle operating between 1.4 bar and 9bar using R-125 as the refrigerant, which removes heat from a cold space at a rate of 100kW. If the evaporator outlet was suddenly superheated by 2℃ above saturation, what will be the resulting effect on the cycle? a.Refrigerant flowrate will decrease, Condenser duty will decrease b.Refrigerant flowrate will increase, Condenser duty will decrease c.Refrigerant flowrate will increase, Condenser duty will increase d.Refrigerant flowrate will decrease, Condenser duty will increasearrow_forward
- Working fluid is Refrigerant 134a. Vapor-compression refrigeration system has refrigerating capacity = 1650 Btu/hour. Refrigerant enters evaporator at -10F and leaves at 15F. Isentropic compressor efficiency = 74%. Refrigerant condenses at 140F and leaves condenser subcooled at 100F. No large pressure drops through evaporator and condenser. DETERMINE: 1. Pressure of evaporator in lbf/in^2 2. Pressure of condenser in lbf/in^2 3. Mass flow rate in lb/s of refrigerant 134a. 4. Power input in horsepower of compressor. 5. Coefficient of performance.arrow_forwardIn a refrigeration cycle, the working fluid (refrigerant) absorbs heat from the surroundings in this device. O Evaporator O Expansion valve O Compressor O Condenserarrow_forwardA vapor-compression refrigeration system with a capacity of 10 tons has Refrigerant 134a as the working fluid. Information and data for the cycle are provided in the Figure and in the table below. The compression process is internally reversible and can be modeled by pu1.01 = constant. The condenser is water-cooled, with water entering and leaving with a negligible change in pressure. Heat transfer from the outside of the condenser can be neglected. Determine a) the mass flow rate of refrigerant, in kg/s. b) the power input and the heat transfer rate for the compressor, each in kW. c) the coefficient of performance. d) the mass flow rate of the cooling water, in kg/s. e) the rates of entropy production in the condenser and expansion valve, in kW/K. f) the rates of exergy destruction in the condenser and expansion valve, each expressed as a percentage of the compressor power input. Let To = 20°C. State p (bar) 1 4 12 11.6 2 3 4 4 5 6 . T (°C) 15 54.88 44 8.93 20 30 Ty=44°C Py = 11.6 bar…arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Refrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
The Refrigeration Cycle Explained - The Four Major Components; Author: HVAC Know It All;https://www.youtube.com/watch?v=zfciSvOZDUY;License: Standard YouTube License, CC-BY