A parking lot is 275 ft by 200 ft (Figure 14-23). A trade size 4 conduit has been buried 2 ft beneath the concrete. The conduit runs at an angle from one corner of the parking lot to the other. Two pull boxes have been placed in the conduit run. The pull boxes are equally spaced along the length of conduit. Your job is to pull conductors through the conduit from one end of the run to the other.
FIGURE 14-23 Determining length.
Allowing 12 ft of extra conductor, what is the length of each conductor? The conductors are not to be spliced.
How much cable will be required to pull these conductors through the conduit, allowing an extra 5 ft at one end that is to be connected to the pulling device and 3 ft extra that is to be used to connect the conductors to the cable?
Trending nowThis is a popular solution!
Chapter 14 Solutions
Delmar's Standard Textbook Of Electricity
- QUESTION 14 What is the minimum sized Rigid Metal Conduit we should use for the above wire run if it is over 24inches long? a 1" b 1 1/4" c 1 1/2" d 2"arrow_forwardA cable wire maybe coaxial or twisted. Coaxial costs 25 centavos per meter while twisted wire costs only 18 centavos. The soldering cost for coaxial wire is P1.30 per connection, for twisted wire P1.70. What length of cable run will make the cost of installing coaxial equal to that of the twisted wire. Assume that the number of soldered connection is 350. ANSWER_____________marrow_forwardIdentify and describe the step-by-step procedure that is used to draw cable, as well as the step-by-step approach that is used to install cable in structures.arrow_forward
- Please draw the winding if needed ? Show complete solution please thank youuarrow_forwardWhere run across the top of floor joists or within ______ ft of the floor or floor joists across the face of rafters or studding, in an attic that has permanent stairs, nonmetallic-sheathed cable must be protected by substantial guard strips that are at least as high as the cable. Select one: A. 6 B. 7 C. 8 D. 5arrow_forwardUsing the cable layout shown in Figure 14-1, make a complete wiring diagram of Circuit A21. Use colored pencils or pens.arrow_forward
- 16. Flexible metal conduit will be installed between a raceway and a transformer in a system. If it's to serve as an equipment grounding conductor, the flexible conduit and its fittings must be less than _______ feet. A. 2 B. 6 C. 10 D. 4 17. In which of the following situations can an equipment ground conductor be run separately from the circuit conductors? A. When you install a GFCI and are connecting additional receptaclesB. When the connection is to be made to a nearby water pipeC. When you're replacing an ungrounded two-wire receptacle with a grounded receptacle D. When there are no spare conductors in the cable 18. A 400-amp circuit breaker protects a feeder that's installed in a nonmetallic raceway that requires an equipment grounding conductor. Which of the following is the minimum size of aluminum equipment grounding conductor that should be used in this situation? A. No. 4B. No. 1C. No. 6 D. No. 2 19. Which of the following is bonded to the grounding electrode system…arrow_forwardExplain what it means to install "conductors in parallel," and give five conditions that must be satisfied when this is done.arrow_forwardNEC identifies ____ types of rigid PVC conduit. Select one: A. FIVE B. TEN C. THREE D. TWOarrow_forward
- 5. What is the minimum size of rigid metal conduit? a. 3/8 inch trade size b. b. ¾ inch trade size c. c. ¼ inch trade size d. d. ½ inch trade sizearrow_forwardXLPE insulated high voltage underground cable will be installed along a street. The cable will then continue on a street route that cuts the street perpendicularly. Since the cable diameter is 10 cm, what should be the minimum bend radius of the cable?arrow_forwardWhere nonmetallic-sheathed cable is run at angles with joists in unfinished basements, it shall be permissible to secure cables not smaller than three ______ AWG conductors directly to the lower edges of the joists. Select one: A. 8 B. 10 C. 6 D. 12arrow_forward
- Delmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage LearningEBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT