Principles of Instrumental Analysis, 6th Edition
6th Edition
ISBN: 9788131525579
Author: Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher: Cenage Learning
expand_more
expand_more
format_list_bulleted
Question
Chapter 17, Problem 17.6QAP
Interpretation Introduction
Interpretation:
The reason of more precise and accurate quantitative analytical methods based on NIR radiation than methods based on mid-IR radiation should be determined.
Concept introduction:
The mid-absorption region of the IR spectroscopy provides important information about the presence of
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
What is the significance of selecting a "representative" sample for chemicalanalysis, and how does this practice ensure accurate and reliable results withrespect to chemical analyses?
Note: The Emission Intensity of the original solution is not given since the calibration method is standard addition.
If the standard addition intercept is the major source of uncertainty, find the uncertainty in the concentration of Sr in tooth enamel in parts per million. Find the 95% confidence interval for Sr in tooth enamel.
Chapter 17 Solutions
Principles of Instrumental Analysis, 6th Edition
Knowledge Booster
Similar questions
- A 25.0 mL aliquot was taken from a 500.0 mL sample of tonic water containing an unknown amount of quinine and diluted to a volume of 200 mL. At 347.5 nm, the fluorescence intensity of the diluted sample was measured 85.7 an arbitrary scale. Under similar conditions, a 27.5 ppm standard quinine solution had a fluorescence intensity of 185. Calculate the mass of quinine in the original tonic water sample in mg. Do not include units in your answer.arrow_forwardQuality assurance. Tin can be leached (dissolved) into canned foods from the tin-plated steel can. (a) For analysis by inductively coupled plasma–atomic emission, food is digested by microwave heating in a Teflon bomb (Figure 2-18) in three steps with HNO3, H2O2, and HCl. CsCl is added to the final solution at a concentration of 1 g/L. What is the purpose of the CsCl?arrow_forwardChemistry Common Isotopes and Mass spectrum of element Mo are given below Most common isotopes: Mo-98; Mo-96 Mo-95; Mo-92; Mo-97 ; Mo-100; Mo-94 Calculate the average atomic mass of Mo How the MS determined the relative intensity (Scale of 100) and Isotope abundance (%)? Why absolute intensity was not used? Can detector sensitivity, ICPMS temperature influence the relative intensity? Explainarrow_forward
- 2. The observed nuclear moments of 209 Bi are: I=9/2; μ = + 4.1 μN; Q=-0.4 x 10-28 m² Determine the expected values for these moments according to the simple Shell model and comment on any significant differences.arrow_forwardSuppose the difference in rest energy of the neutron and proton were Qn = (mn − mp)c2 = x MeV instead of Qn = 1.29MeV, with all other physical parameters unchanged. Estimate Ymax, the maximum possible mass fraction in 4He, assuming that all available neutrons are incorporated into 4He nuclei. Hint: Compare the new rest energy of the neutron to the electron and consider how that would impact the decay of neutrons. Will free neutrons decay at all in this scenario? If the neutron decay is negligible, then the ratio of protons to neutrons to protons will remain the same as it was at the time of freeze-out (for a given Qn). Value: x=0.158 MeVarrow_forward14 g of nitrogen gas were reacted with excess hydrogen. Calculate the volume of amonia produced under standard conditions. ( 101 kPa, 298K) R= 8.31 JK mol-1arrow_forward
- To quantify the Cadmium content in a water sample, 5 aliquots of 10 mL were taken, adding to each one of them a volume of a standard solution of Cd (2 mg / mL); after the addition the final volume for all solutions was 50 mL. The absorbance reading was taken in an Atomic Absorption spectrophotometer, the data recorded were: Aliquot 1 2 3 4 5 Cd solution (mL) 0 1 2 3 4 Absorbance 0.163 0.240 0.319 0.402 0.478 Calculate the ppm of Cd.arrow_forwardThe radioisotope cobalt-60 is a strong gamma-emitter. It would be useful for analyzing materials for internal defects nuclear fuel chemical reactions involving cobalt injecting into a person to get internal x-ray picturesarrow_forwardIn the HQS-Mg fluorescence part of Lab 6, a calibration curve is made of fluorescence intensity vs. MgCl2 concentration (M). The standard solutions for the calibration curve were made by mixing a small amount of 0.01 M MgCl2 with some HQS solution. Calculate the concentration of MgCl2 (M) in each of the following standards. Report your concentrations to 3 sig figs. Fluorescence Volume of 0.01 M Volume of 1 mM Concentration of MgCl2 (M) Intensity MgCl2 (mL) HQS (mL) 0.031250902 0.8 100 0.049490754 0.8 50 0.059803507 2 100 0.085834029 3.6 100 Hint: The total volume of each solution is volume of 0.01 M MgCl2 + volume of 1 mM HQS.arrow_forward
- Quinine in a 1.553-g antimalarial tablet was dissolved in sufficient 0.10 M HCl to give 250 mL of solution.A 10.00-mL aliquot was then diluted to 50.00 mL with the acid. The fluorescence intensity for the dilutedsample at 347.5 nm provided a reading of 196 on an arbitrary scale. A standard 100-ppm quinine solutionregistered 125 when measured under conditions identical to those for the diluted sample. Calculate the massin milligrams of quinine in the tablet.arrow_forwardDefine the following terms: Molecular ion Fragment ion Abundance/Relative Intensity Mass to charge ratio (m/z)arrow_forwardNonearrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage LearningChemistry for Engineering StudentsChemistryISBN:9781337398909Author:Lawrence S. Brown, Tom HolmePublisher:Cengage LearningGeneral, Organic, and Biological ChemistryChemistryISBN:9781285853918Author:H. Stephen StokerPublisher:Cengage Learning
- Organic And Biological ChemistryChemistryISBN:9781305081079Author:STOKER, H. Stephen (howard Stephen)Publisher:Cengage Learning,Introduction to General, Organic and BiochemistryChemistryISBN:9781285869759Author:Frederick A. Bettelheim, William H. Brown, Mary K. Campbell, Shawn O. Farrell, Omar TorresPublisher:Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning
Chemistry for Engineering Students
Chemistry
ISBN:9781337398909
Author:Lawrence S. Brown, Tom Holme
Publisher:Cengage Learning
General, Organic, and Biological Chemistry
Chemistry
ISBN:9781285853918
Author:H. Stephen Stoker
Publisher:Cengage Learning
Organic And Biological Chemistry
Chemistry
ISBN:9781305081079
Author:STOKER, H. Stephen (howard Stephen)
Publisher:Cengage Learning,
Introduction to General, Organic and Biochemistry
Chemistry
ISBN:9781285869759
Author:Frederick A. Bettelheim, William H. Brown, Mary K. Campbell, Shawn O. Farrell, Omar Torres
Publisher:Cengage Learning