Applied Fluid Mechanics (7th Edition)
7th Edition
ISBN: 9780132558921
Author: Robert L. Mott, Joseph A. Untener
Publisher: PEARSON
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 19, Problem 19.20PP
To determine
Velocity of flow and Velocity of pressure in all parts of the duct.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
. What horsepower is supplied to air moving at 7m/min through a 70cmx90cm duct under a pressure of8cm of H2O?
Compare a orifice plate for low speed to a Pitot Static Tube.
A pump is used to lift water at ambient temperature from one tank to another at a rate of 08/50 m3/min. If the pipe diameter is 4 in, calculate the power required to run the pump (efficiency 70%). The pipe material is commercial steel and contains 3 standard radius elbows. Assume h=1 cP.
Calculate the Reynolds number and the friction head loss using the Moody chart attached,
Using Colebrook equation.
Calculate the other losses and the total loss,
(Calculate the required power.
Flow rate is not necessary for answering the question.
Chapter 19 Solutions
Applied Fluid Mechanics (7th Edition)
Ch. 19 - Determine the velocity of flow and the friction...Ch. 19 - Repeat Problem 19.1 O for duct diameters of 16,...Ch. 19 - Prob. 19.3PPCh. 19 - Determine the velocity of flow and the friction...Ch. 19 - Repeat Problem 19.40 for duct diameters of...Ch. 19 - Prob. 19.6PPCh. 19 - Prob. 19.7PPCh. 19 - '19.8 A branch duct for a heating system measures...Ch. 19 - Prob. 19.9PPCh. 19 - Prob. 19.10PP
Ch. 19 - A branch duct for a heating system measures 75250...Ch. 19 - Prob. 19.12PPCh. 19 - Prob. 19.13PPCh. 19 - Prob. 19.14PPCh. 19 - Repeat Problem 19.14, but use a five-piece elbowCh. 19 - Prob. 19.16PPCh. 19 - Prob. 19.17PPCh. 19 - Prob. 19.18PPCh. 19 - Prob. 19.19PPCh. 19 - Prob. 19.20PPCh. 19 - Compute the pressure drop as 0.20m3/s of air flows...Ch. 19 - Prob. 19.22PPCh. 19 - Compute the pressure drop as 0.85m3/s of air flows...Ch. 19 - A section of duct system consists of 42 ft of...Ch. 19 - A section of duct system consists of 38 ft of...Ch. 19 - The intake duct to a fan consists of intake...Ch. 19 - Forthe conditions shown in figs. 19.719- 19.10 0,...Ch. 19 - Forthe conditions shown in figs. 19.719- 19.10 0,...Ch. 19 - Prob. 19.29PPCh. 19 - Forthe conditions shown in figs. 19.719- 19.10 0,...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A round main supply duct will carry an airflow of 2,000 CFM with a static pressure drop of 0.325” w.c. What size duct diameter will each branch be?arrow_forwardCalculate the minimum velocity of flow in ft/s of water at 160°F in a 2-in steel tube with a wall thickness of 0.065 in for which the flow is turbulent.arrow_forwarda pipe reducer with the pressure at A and B is 345kPa and 290kPa. the diameter at A and B is 50mm and 25mm. estimate the total head at point A and B?arrow_forward
- Inorder to achieve a liquid flow rate of 500 gal/min with a maximum pressure difference of 42 psi, calculate the value of valve flow coefficient. The specific gravity of liquid is 1.3.arrow_forwardDetermine the power requirements for 3 m diameter, six-blade flatblade turbine impeller mixer running at 15 rpm in a 10 m diametermixing tank. Assume the fluid being mixed is water.arrow_forwardFrancis and Kaplan turbines are often provided with drafttubes, which lead the exit fl ow into the tailwater region, asin Fig. . Explain at least two advantages in using adraft tube.arrow_forward
- Calculate the resistance coefficient K for a check valve swing type placed in a 6 inch schedule 40 steel pipe if water at 100º F flowing with a velocity of 10 ft/sarrow_forwardCalculate the power supplied to the pump shown if its efficiency is 75%. Water is at 25 degrees Celsius is flowing at the rate of 50.0 m3/h. The suction linf is a standard DN 100 Schedule 40 steel pip, 15m long. The total length of DN 50 Schedule 40 steel pipe in the discharge line is 200m. The elbows are tight, the entrance to the pipe is flush and the globe valve is completely open. Draw the line of total and piezometric heights.arrow_forwardSaturated water at 310K is being pumped from a tank to an elevated tank at the rate of 7L/s. All of the piping is in 5-in. schedule 40 steel pipe. If the 2 fittings used is 90° ell standard long radius, The pump has an efficiency of 80%. Calculate the total friction losses in kJ/kg.arrow_forward
- Plot the variation of pressure with area for four different pump speeds. COURE NAME: THERMOFLUIDSarrow_forwardThe pressure drop across a turbine is 25 psi. The flow rate is 55gal/min. Calculate the power output of the turbine.arrow_forwardCompute the volumetric gas flow in the duct (m3/s)arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Refrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
8.01x - Lect 27 - Fluid Mechanics, Hydrostatics, Pascal's Principle, Atmosph. Pressure; Author: Lectures by Walter Lewin. They will make you ♥ Physics.;https://www.youtube.com/watch?v=O_HQklhIlwQ;License: Standard YouTube License, CC-BY
Dynamics of Fluid Flow - Introduction; Author: Tutorials Point (India) Ltd.;https://www.youtube.com/watch?v=djx9jlkYAt4;License: Standard Youtube License