Question
Chapter 21.1, Problem 10R
To determine
State whether the receptacle must be GFCI protected or not when it installed under the kitchen sink for plugging in the food waste disposer.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
ladder diagram for bottom half of a switched receptacle is to always be hot plus a duplex receptacle that is controlled from two locations using a coast 3-way wiring system multiwire circuit
ladder diagram for bottom half of a switched receptacle is to always be hot plus a duplex receptacle that is controlled from two locations using a coast 3-way wiring system
Which room makes use of Split-Circuit receptacles?
Chapter 21 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- a. The Code requires a minimum of two small-appliance circuits in a kitchen. Is it permitted to connect a receptacle in a dining room to one of the kitchen small-appliance circuits? _______________ What Code section applies to this situation? _______________ b. Are outdoor weatherproof receptacles permitted to be connected to a 20-ampere small-appliance circuit? _______________ c. Receptacles located above the countertops in the kitchen must be supplied by at least _______________ 20-ampere small-appliance circuits.arrow_forwardIs a GFCI receptacle permitted be installed as a replacement in an old installation where the 2-wire circuit has no equipment grounding conductor? _________________arrow_forwardConstruction sites can be dangerous because of the manner in which extension cords, portable electrical tools, and other electrical equipment are used and abused. To reduce this hazard, 590.6(A) of the NEC requires that all 125-volt, single-phase, 15-, 20-, and 30-ampere receptacle outlets used for temporary wiring during construction must be _________________ protected.arrow_forward
- Why is it permissible to omit an electric space heater, water heater, and certain other 240-volt equipment when calculating the neutral service-entrance conductor for a residence? ____arrow_forwardRefer to the specifications in the back of this text following Chapter 33. a. What electrical codes must be conformed to? ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ b. What is the wiring method to be used in the workshop? ________________________________________________________________________ c. What size conductors are to be used for the lighting branch circuits? ______________________ AWG the small-appliance branch circuits? ______________________ AWG d. What section of the specifications tells us the size of the service entrance to be installed for this residence?arrow_forwardWhich of the following installations for a kitchen waste disposal that operates on a 15-ampere, 120-volt branch circuit requires AFCI protection? (Circle the correct answer.) a. The disposal operates by a switch that is installed above the kitchen counter. b. The disposal operates by a switch that is installed under the counter next to the disposal. c. Both (a) and (b) d. Neither (a) nor (b).arrow_forward
- What is the Code requirement for receptacles connected to circuits of different voltages and installed in one building?_____________________arrow_forwardThe following is a layout of the lighting circuit for the Laundry, Powder Room, Rear Entry Hall, and Attic. Complete the wiring diagram using colored pens or pencils to indicate conductor insulation color. The GFCI receptacle in the Powder Room is not shown in the diagram because it is connected to a separate circuit, B21.arrow_forwardWhich five areas use GFCI-protected receptacles?arrow_forward
- You are asked to replace an ungrounded receptacle (two wire) and there is not a source of ground available. 1. It is permissible to replace the receptacle with a GFCI receptacle? 2. If so, how must the receptacle plate be marked. Be sure and cite code references.arrow_forwardAssuming all terminals are rated 75 degrees Celsius, and you have six (6) #10 AWG THHN/THWN conductors in a conduit and the conduit is run inside an office building, What is the largest size circuit breaker or fuse permitted to protect this wire?arrow_forwardThe NEC is the only code reference used for electrical installations of all types of occupancies including dwelling for physically challenged persons. True or False?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT