Question
Chapter 22.3, Problem 1R
To determine
Name the circuit that provides the power supply to the hydromassage bathtub.
Expert Solution & Answer
Answer to Problem 1R
A9 circuit supplies the power to the hydromassage bathtub.
Explanation of Solution
Description:
Hydromassage bathtub is a regular bathtub with recirculating piping system and an electric pump. The electric pump in the hydromassage bathtub circulates the water. Hydromassage bathtub is also termed as a whirlpool bath.
A dedicated branch circuit A9 supplies the required power to the hydromassage bathtub. A9 branch circuit is a 15 A, 120 V electrical circuit.
Conclusion:
Thus, the A9 circuit supplies the power to the hydromassage bathtub.
Want to see more full solutions like this?
Subscribe now to access step-by-step solutions to millions of textbook problems written by subject matter experts!
Students have asked these similar questions
16. The _______ point is where the facilities of the serving utility and the premises wiring connect.A. groundedB. neutralC. serviceD. bonding
19. Which of the following is an approved disconnecting means for a feeder or branch circuit supplying a separate building or structure?
A. Bonding locknutB. PanelboardC. Circuit breakerD. Overcurrent device
QUESTION 25
Type TC cable shall not be _____.
a.
installed where it will be exposed to physical damage
b.
all of these
c.
installed outside of a race-way or cable tray system, unless permitted in 336.10(4), 336.10(7), 336.10(9), and 336.10(10)
d.
used where exposed to direct rays of the sun, unless identified as sunlight resistant
Chapter 22 Solutions
Electrical Wiring Residential
Ch. 22.1 - Prob. 1RCh. 22.1 - Prob. 2RCh. 22.1 - Prob. 3RCh. 22.1 - Prob. 4RCh. 22.1 - Prob. 5RCh. 22.1 - Prob. 6RCh. 22.1 - Prob. 7RCh. 22.1 - Prob. 8RCh. 22.1 - Prob. 9RCh. 22.1 - Prob. 10R
Ch. 22.1 - Prob. 11RCh. 22.1 - Prob. 12RCh. 22.2 - Prob. 1RCh. 22.2 - Prob. 2RCh. 22.2 - Prob. 3RCh. 22.2 - Prob. 4RCh. 22.2 - Prob. 5RCh. 22.2 - Prob. 6RCh. 22.2 - Prob. 7RCh. 22.2 - Prob. 8RCh. 22.2 - Prob. 9RCh. 22.2 - Prob. 10RCh. 22.2 - Prob. 11RCh. 22.2 - Prob. 12RCh. 22.3 - Prob. 1RCh. 22.3 - Which of the following statements Meets Code?...Ch. 22.3 - Prob. 3RCh. 22.3 - Prob. 4RCh. 22.3 - Prob. 5RCh. 22.3 - Prob. 6RCh. 22.3 - Prob. 7RCh. 22.3 - Prob. 8R
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Refer to the specifications in the back of this text following Chapter 33. a. What electrical codes must be conformed to? ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ b. What is the wiring method to be used in the workshop? ________________________________________________________________________ c. What size conductors are to be used for the lighting branch circuits? ______________________ AWG the small-appliance branch circuits? ______________________ AWG d. What section of the specifications tells us the size of the service entrance to be installed for this residence?arrow_forwardThe following is a layout of the lighting circuit for the Laundry, Powder Room, Rear Entry Hall, and Attic. Complete the wiring diagram using colored pens or pencils to indicate conductor insulation color. The GFCI receptacle in the Powder Room is not shown in the diagram because it is connected to a separate circuit, B21.arrow_forwardMay the 20-ampere small-appliance branch circuits in the kitchen of a residence also supply the lighting above the kitchen sink and under-cabinet lighting? Check the correct answer. Yes______ No ______arrow_forward
- The recessed fluorescent luminaires installed in the ceiling of the recreation room of this residence are connected with trade size flexible metal conduit. These flexible connections are commonly referred to as fixture whips. Does the flexible metal conduit provide adequate grounding for the luminaires, or must a separate equipment grounding conductor be installed? ________________arrow_forwardHow many circuit wires enter the entry ceiling box? How many equipment grounding conductors enter the entry ceiling box?arrow_forwardAssuming that an outlet box for the entry ceiling has a fixture stud but has external cable clamps, what size box could be installed? Show calculations for both metal and nonmetallic boxes. ___________arrow_forward
- A metal well casing (shall) (shall not) be bonded to the pumps equipment grounding conductor or by grounding it with a separate equipment grounding conductor run all the way back to the same ground bus in the panelboard that supplies the pump circuit, NEC ______________________________________________________________________arrow_forwardWhy is it permissible to omit an electric space heater, water heater, and certain other 240-volt equipment when calculating the neutral service-entrance conductor for a residence? ____arrow_forwardelectrical wiring 20th edition residential book chapter 12 review question #27 The following is a layout for the lighting circuit for the Kitchen. Complete the wiring diagram using colored pens or pencils to show the conductors’ insulation color.arrow_forward
- Approximately how many feet (meters) of 2-wire cable and 3-wire cable are needed to complete the circuit supplying the Master Bedroom? Two-wire cable: ___________ ft (___________ m). Three-wire cable: ___________ ft (___________ m).arrow_forwardList the minimum service drop clearances required by the NEC in the following residential situations. A driveway _____feet? A lawn ____feet? A roof with a slope of 5/12 ____feet? A garage roof with a slope of 3/12 _____feet?arrow_forwardWhen installing ceiling-suspended (paddle) fans, per the requirements found in NEC 314.27(C) and NEC 422.18 and the UL Product Spec database, the outlet box or outlet system consist of the following:arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENTDelmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning
Pressure Sensors with Display; Author: Balluff Worldwide;https://www.youtube.com/watch?v=HqAV2xjCLxE;License: Standard Youtube License