Introductory Circuit Analysis
13th Edition
ISBN: 9780133923919
Author: Boylestad, Robert L.
Publisher: Pearson Education
expand_more
expand_more
format_list_bulleted
Concept explainers
Textbook Question
Chapter 23, Problem 15P
For the transformer in Fig. 23.61, if the resistive load is replaced by an inductive reactance of 20
- Determine the total reflected primary impedance
- Calculate the primary current, Ip
- Determine the voltage across Re and Xe, and find the reflected load.
- Draw the phasor diagram.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A 4800- Vrms transmission line feeds a distribution transformer with 1200 turns on the primary and 28 turns on the secondary . When a 10-Ohm load is connected across the secondary . Find ?
a ) the secondary voltage
Suppose three equal loads of 25<30° are Δ connected. The terminal voltage of impedances is 6.9 kV. If impedance of each transmission line connecting each load to a bus is 2<65°. What is the terminal voltage of the substation bus?
Complete the sentence
The power factor must be close to ……………. To insure that losses in the transmission lines will be reduced
Chapter 23 Solutions
Introductory Circuit Analysis
Ch. 23 - For the air-core transformer in Fig. 23.57: Find...Ch. 23 - Repeat Problem 1 if k is changed to 1. Repeat...Ch. 23 - RepeatProblem1fork=0.3,NP=300turns,andNS=25turns.Ch. 23 - For the iron-core transformer (k = 1) in Fig....Ch. 23 - RepeatProblem4forNP=240andNS=30.Ch. 23 - Find the applied voltage of an iron-core...Ch. 23 - If the maximum flux passing through the core of...Ch. 23 - For the iron-core transformer in Fig. 23.59: Find...Ch. 23 - Find the input impedance for the iron-core...Ch. 23 - Find the voltage Vg, and the current Ip if the...
Ch. 23 - If VL=240V,ZL=20resistor,Ip=0.05AandNs=50 find the...Ch. 23 - If Np400,Ns=1200andVg=100V,findthemagnitudeofIp...Ch. 23 - For the circuit in Fig. 23.60, find the...Ch. 23 - For the transformer in Fig. 23.61, determine the...Ch. 23 - For the transformer in Fig. 23.61, if the...Ch. 23 - Prob. 16PCh. 23 - Discuss in your own words the frequency...Ch. 23 - Determine the total inductance of the series coils...Ch. 23 - Determine the total inductance of the series coils...Ch. 23 - Determine the total inductance of the series coils...Ch. 23 - Write the mesh equations for the network in Fig....Ch. 23 - Determine the input impedance to the air-core...Ch. 23 - An ideal transformer is rated...Ch. 23 - Determine the primary and secondary voltages and...Ch. 23 - For the center-tapped transformer in Fig. 23.42,...Ch. 23 - For the multiple-load transformer in Fig. 23.43,...Ch. 23 - Prob. 27PCh. 23 - Write the mesh equations for the network of Fig....Ch. 23 - Write the mesh equations for the network of Fig....Ch. 23 - A current transformer has a secondary with 250...Ch. 23 - Generate the schematic for the network in Fig....Ch. 23 - Prob. 32PCh. 23 - Using a transformer from the library find the load...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Q4: A 50 Hz, 11KV, 3-ph, alternator with earthed neutral has a reactance of 5 Ω\ ph and is connected to bus bar through a C.B. The distributed capacitance up to C.B between phase and neutral is 0.01μF, determine: 1-the recovery voltage across the contacts of the breaker, 2-the frequency of oscillation, 3- The restriking voltage across the contacts of the breaker, 4-the average rate of rise of restriking voltage up to the first peak, 5- the time to reach the peak restriking voltage, 6- the value of resistance to be used across the contacts of C.B. to eliminate the restriking voltage, and 7- the value of inductance and capacitance of this systemarrow_forwardA three-phase wye-connected generator is connected to an industrial motor load. The generator has an output coil voltage of 120 V, a coil current of 15 A, and a lagging power factor angle of 40 degrees. Find the line voltage, the line current, the total apparent power, and the total true power.arrow_forwardWhat is the phase sequence of a three-phase alternator connected in Y for which e,<(image)>. moreover find Vcnarrow_forward
- A critical factor in the section of a generation of a generator for a particular application is that ______? A. It must fit on the applicable concrete pans and match the décor of the commercial building B. It must have the same voltage output as the normal building power supply C. The fuel supply must be available only 50% of allowable time D. The repair parts must be manufactured and conform to the ISO 9001 standards.arrow_forwardQ26/B Discuss the current transformer with neat schematic diagram.arrow_forwardIt is desired to purchase a synchronous condenser to correct the 2,400-KVA 0.67-lagging power factor load in an industrial plant to 0.95 lagging. Neglect losses, calculate: (a) the kilovolt-ampere input rating of the required synchronous condenser; (b) the total kilovoltamperes of the plant. Using the phasor diagram.arrow_forward
- In the Open-circuit test of the transformer (OC TEST), wattmeter measures 2 kW, in the short-circuit test of the transformer (SC TEST) wattmeter measures 200kW. Find the core loss of the transformer?arrow_forward. For the iron-core transformer (k == 1) in Fig. 23.58: + E = 40 V √=60H/ N₁ = 20 HANN HA MARE, LA N. = 120 a. Find the magnitude of the induced voltage E. b. Find the maximum fluxarrow_forwardIdentify the company or private distributor of electricity involved in primary power distribution in the PHILIPPINES. (Example: NGCP)arrow_forward
- 9/ Incoming and outgoing lines in a substation are connected to a Busbar. Select one: True Falsearrow_forwardIn 132 kV transmission system, the phase to ground capacitance is 0.01micro F. The inductance being 4 H. Calculate the voltage appearing across the pole of a circuit breaker if a magnetizing current of 9 A is interrupted. Find the value of resistance to be used across contact space to eliminate the striking voltage transient.arrow_forwarda plant is feeding a load 1.2k feet away. the load demands 100 amps at 500V. an ac system with transformer rated 500/5000V near the generating station and 5000/500V near the load. if the line has resistance of 0.2 ohms and receiving voltage of 500V, find the sending end voltage and powerflows and transmission losses.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Introductory Circuit Analysis (13th Edition)Electrical EngineeringISBN:9780133923605Author:Robert L. BoylestadPublisher:PEARSONDelmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage LearningProgrammable Logic ControllersElectrical EngineeringISBN:9780073373843Author:Frank D. PetruzellaPublisher:McGraw-Hill Education
- Fundamentals of Electric CircuitsElectrical EngineeringISBN:9780078028229Author:Charles K Alexander, Matthew SadikuPublisher:McGraw-Hill EducationElectric Circuits. (11th Edition)Electrical EngineeringISBN:9780134746968Author:James W. Nilsson, Susan RiedelPublisher:PEARSONEngineering ElectromagneticsElectrical EngineeringISBN:9780078028151Author:Hayt, William H. (william Hart), Jr, BUCK, John A.Publisher:Mcgraw-hill Education,
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:PEARSON
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning
Programmable Logic Controllers
Electrical Engineering
ISBN:9780073373843
Author:Frank D. Petruzella
Publisher:McGraw-Hill Education
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:9780078028229
Author:Charles K Alexander, Matthew Sadiku
Publisher:McGraw-Hill Education
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:9780134746968
Author:James W. Nilsson, Susan Riedel
Publisher:PEARSON
Engineering Electromagnetics
Electrical Engineering
ISBN:9780078028151
Author:Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:Mcgraw-hill Education,
TRANSFORMERS - What They Are, How They Work, How Electricians Size Them; Author: Electrician U;https://www.youtube.com/watch?v=tXPy4OE7ApE;License: Standard Youtube License