Concept explainers
For the multiple-load transformer in Fig. 23.43, where
- Determine the load voltages and currents.
- Calculate Z1.
Want to see the full answer?
Check out a sample textbook solutionChapter 23 Solutions
EBK INTRODUCTORY CIRCUIT ANALYSIS
- A 6.9 kV/600 V, multi-tap, single-phase distribution transformer is connected to the far end of a distribution line for which the rear end voltage is maintained at 6.9 kV. The equivalent impedance of the transformer referred to low voltage side is 0.05 + j0.25 Ω per phase. The impedance of each line is 1 + j2 Ω. It is required to maintain a terminal voltage of 600 V when the line current of 300 A at 80% pf lagging is delivered to the load. What approximate percentage tapping is required in the primary side? Neglect the changes in impedance due to changes in turns ratio.arrow_forward A 2.4 kVA, 2400/240 V 50 Hz step downtransformer has the following parameters R1= 1.5Ω, X1= 2.5Ω, R2 = 0.02Ω, X2 =0.03Ω,Rc1 = 6kΩ, Xm1 = 8kΩ It is operating at 80% of its rated load at 0.8power factor lagging. Using the approximateequivalent circuit of the transformer referredto the secondary side, determine its efficiency, the voltage regulation andsketch its phasor diagram.arrow_forwardIn a cold storage, cosφ = 0.9 for 8 various motors, the total power of the motors is 48kW, the synchronicity factor of the facility is 0.70, and for lighting, 8 60W, 2 100W incandescent lamps (cosφ = 1) 4 pieces of 125W, 2 pieces of 250W, 3 pieces of 400W sodium vapor lamps (cosφ = 0,8) are used. Find the power of the distribution transformer to be selected. (Norm transformer powers: 50KVA, 100 KVA, 160 KVA, 250KVA, 400 KVA, 630 KVA, 800KVA, 1250KVA, 1600KVA)arrow_forward
- A 40-kVA, 8000/230-V distribution transformer has an impedance referred to the primary of 18 + j80 Ω. The components of the excitation branch referred to the primary side are Rc = 100 kΩ and Xc = 20 kΩ. If the primary voltage is 7920 V and the load impedance is ZL = 1.5 + j*0.7 Ω what is the secondary voltage, in volts?arrow_forwardMr. Musa Al Biruni is analyzing a 100 kVA, 60 Hz, 7200-480V, single phase transformer, which hasthe following parameters expressed in ohms: RHS=3.06, XHS=6.05, XM,HS=17809, RLS=0.014,XLS=0.027, Rfe,HS=71400The transformer is supplying a distribution side load that draws a rated current at 480V and 75percent power-factor lagging. Sketch the appropriate equivalent circuit and determine (a) theequivalent resistance and equivalent reactance referred to high side (b) the input voltage to thetransformerarrow_forwardThe low voltage side of a particular transformer has 747 turns while its high voltage side has 69471 turns,when connected as a step-up transformer, its secondary impedance is 371907 + J 250821 ohms. What is thenequivalent of this impedance in the primary side of the transformer?arrow_forward
- An Electrical engineer is asked by a client to prepare a technical specification on specific items connected with a project. Hence, the engineer is requested to prepare the technical specification of the following: PROJECT: A Subdivision Development Lot AREA; 2 Hectares LOCATION: Brgy. Kanlurang Mayao, Lucna City Technical specification of fuse cutout Technical specification of transformerarrow_forwardA 4500/16000V, 1500 kVA, 50 Hz transformer has the following parameters: R1 = 0.03 Ω, R2 = 0.44 Ω, R0 = 1688 Ω X1 = 0.092 Ω, X2 = 1.34 Ω, X0 = 256 Ω The transformer is supplying full- load at power factor of 0.8 lagging. Using exact equivalent circuit, find the input currenarrow_forwardA single-phase, 50kVA, 2400:240V distribution transformer has an impedance of 0.72+j0.92Ω from the high voltage winding and 0.007+j0.009Ω from the low voltage winding. This transformer is supplied by a feeder whose impedance is 0.3+j1.6Ω. Determine the voltage at the emitter terminal of the feeder when the load connected to the transformer secondary draws rated current at 240V with 0.8 lagging power factor. For this case, it is convenient to use the approximate circuit of the transformer given below. PLEASE, TYPE, HAND WRITING GETS UNDERSTANDING,arrow_forward
- Given a 115kV/13.2kV distribution transformer rated at 30MVA with an 8% nameplate impedance what is the full Load current in ampsarrow_forwardA 200 kVA, 440/11000 V single phase transformer has an effective impedance of (4 + j9) ohm on the secondary side. Estimate the following : 1) The effective resistance in the primary side in mΩ 2)The effective reactance in the primary side in mΩ 3)The short circuit voltage on the secondary side.arrow_forwardElectrical engineering A 375 kVA, 6600/400 V, 3-phase core type transformer has a total loss of 3700 watts on full load. The transformer tank is 1.25 m in height and 1 m × 0.5 m in plan. Design a suitable scheme for cooling tubes if the average temperature rise is to be limited to 35 °C. The diameter of the tube is 50 mm and are spaced 75 mm from each other. The average height of the tube is 1.05 m.arrow_forward
- Introductory Circuit Analysis (13th Edition)Electrical EngineeringISBN:9780133923605Author:Robert L. BoylestadPublisher:PEARSONDelmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage LearningProgrammable Logic ControllersElectrical EngineeringISBN:9780073373843Author:Frank D. PetruzellaPublisher:McGraw-Hill Education
- Fundamentals of Electric CircuitsElectrical EngineeringISBN:9780078028229Author:Charles K Alexander, Matthew SadikuPublisher:McGraw-Hill EducationElectric Circuits. (11th Edition)Electrical EngineeringISBN:9780134746968Author:James W. Nilsson, Susan RiedelPublisher:PEARSONEngineering ElectromagneticsElectrical EngineeringISBN:9780078028151Author:Hayt, William H. (william Hart), Jr, BUCK, John A.Publisher:Mcgraw-hill Education,