The electrician mounted the disconnect switch for a central air-conditioning unit 8 ft (2.5 m) above the ground. This was easy to do because all he had to do was run the conduit across the ceiling joists in the basement, through the outside wall, and directly into the back of the disconnect switch. The electrical inspector turned the job down, citing NEC ______ that requires that the disconnecting operating handle must not be higher than ______ above the ground.

BuyFindarrow_forward

EBK ELECTRICAL WIRING RESIDENTIAL

19th Edition
Simmons
Publisher: CENGAGE LEARNING - CONSIGNMENT
ISBN: 9781337516549

Solutions

Chapter
Section
BuyFindarrow_forward

EBK ELECTRICAL WIRING RESIDENTIAL

19th Edition
Simmons
Publisher: CENGAGE LEARNING - CONSIGNMENT
ISBN: 9781337516549
Chapter 27, Problem 36R
Textbook Problem
28 views

The electrician mounted the disconnect switch for a central air-conditioning unit 8 ft (2.5 m) above the ground. This was easy to do because all he had to do was run the conduit across the ceiling joists in the basement, through the outside wall, and directly into the back of the disconnect switch. The electrical inspector turned the job down, citing NEC ______ that requires that the disconnecting operating handle must not be higher than ______ above the ground.

To determine

Fill the given blanks regarding the location of operating handle with respect to ground.

Explanation of Solution

Discussion:

The National Electrical Code committee develops NEC – the standard electrical code and the main objective for the origin of the code is to protect and safeguard people and elements from electrical hazards.

According to NEC 404.8(A) in the textbook, all the switches, operating handles, and circuit breakers must be located in a readily accessible place. It tells that the highest position of the operating handle must not be greater than 6ft7in.(2

Still sussing out bartleby?

Check out a sample textbook solution.

See a sample solution

The Solution to Your Study Problems

Bartleby provides explanations to thousands of textbook problems written by our experts, many with advanced degrees!

Get Started

Chapter 27 Solutions

EBK ELECTRICAL WIRING RESIDENTIAL
Show all chapter solutions
add
Ch. 27 - What is the minimum size copper grounding...Ch. 27 - What is the recommended height of a meter socket...Ch. 27 - a. Is the bare grounded neutral conductor of a...Ch. 27 - How far must mechanical protection be provided...Ch. 27 - a. A service disconnect is permitted to consist of...Ch. 27 - Complete the following table by filling in the...Ch. 27 - a. What size conductors supply Panelboard B?...Ch. 27 - How many electric meters are provided for this...Ch. 27 - a. According to the NEC, is it permissible to...Ch. 27 - What table in the NEC lists the sizes of grounding...Ch. 27 - NEC 250.53(D)(2) requires that a supplemental...Ch. 27 - Do the following conductors require mechanical...Ch. 27 - Why is bonding of service-entrance equipment...Ch. 27 - What special types of bushings are required on...Ch. 27 - When insulated conductors 4 AWG or larger that are...Ch. 27 - What minimum size copper bonding jumpers must be...Ch. 27 - a. Where is Panelboard A located? __________ b. On...Ch. 27 - When conduits pass through the wall from outside...Ch. 27 - Briefly explain why electrical systems and...Ch. 27 - In general, systems are required to be grounded if...Ch. 27 - To ensure a complete grounding electrode system:...Ch. 27 - An electric clothes dryer is rated at 5700 watts....Ch. 27 - A heating cable rated at 750 watts is used...Ch. 27 - When used as service equipment, a panelboard (load...Ch. 27 - Here are five commonly used terms in the...Ch. 27 - The electrician mounted the disconnect switch for...Ch. 27 - a. According to the NEC definition of a wet...Ch. 27 - When using rebars as the concrete-encased...Ch. 27 - The circuit directory in a panelboard (may)...Ch. 27 - A main service panel is located in a dark corner...Ch. 27 - The term used when the utility charges different...Ch. 27 - A ground rod is driven below the meter outside of...Ch. 27 - Copper-coated steel ground rods are the most...Ch. 27 - What section of the Code prohibits the use of...Ch. 27 - Which section of the NEC prohibits using the space...Ch. 27 - What section of the NEC prohibits using an...Ch. 27 - When wiring a gas furnace, what additional steps,...

Additional Engineering Textbook Solutions

Find more solutions based on key concepts
Show solutions add
The standard taper in most lathe tailstocks is the _______ taper.

Precision Machining Technology (MindTap Course List)

What is a task? What is an event? What is a milestone?

Systems Analysis and Design (Shelly Cashman Series) (MindTap Course List)

What is informatics?

Fundamentals of Information Systems

What is a cost-benefit analysis?

Management Of Information Security

Why is water sprayed on newly poured concrete for some time after it is poured?

Engineering Fundamentals: An Introduction to Engineering (MindTap Course List)

Compute the nominal flexural strength of the composite beam of Problem 9.1-1. Use Fy=50 ksi.

Steel Design (Activate Learning with these NEW titles from Engineering!)

operating system

Enhanced Discovering Computers 2017 (Shelly Cashman Series) (MindTap Course List)

Sketch and briefly describe the three-stage organizational change model.

Principles of Information Systems (MindTap Course List)

If your motherboard supports ECC DDR3 memory, can you substitute non-ECC DDR3 memory?

A+ Guide to Hardware (Standalone Book) (MindTap Course List)