Question
Chapter 27, Problem 25R
To determine
Find the additional provision required on the conduit ends when insulated 4 AWG or larger conductors are required to be insulated.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
QUESTION 25
Type TC cable shall not be _____.
a.
installed where it will be exposed to physical damage
b.
all of these
c.
installed outside of a race-way or cable tray system, unless permitted in 336.10(4), 336.10(7), 336.10(9), and 336.10(10)
d.
used where exposed to direct rays of the sun, unless identified as sunlight resistant
In the conduit layout shown in picture attached, determine how many wires are contained in each conduit between each piece of equipment. Identify each wire with a proper terminal marking, as shown in the example, above the disconnect switch.
Assuming all terminals are rated 75 degrees Celsius, you have three (3) #10 AWG THHN/THWN conductors in a conduit and the conduit is run inside an office building, the largest size circuit breaker or fuse permitted to protect this wire?
Chapter 27 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Ch. 27 - Define the Service Point. ______________Ch. 27 - Define service-drop conductors.Ch. 27 - Prob. 3RCh. 27 - a. The service head must be located (above)...Ch. 27 - Prob. 5RCh. 27 - When a conduit is extended through a roof, must it...Ch. 27 - a. What size and type of conductors are installed...Ch. 27 - How and where is the grounding electrode conductor...Ch. 27 - What are the minimum distances or clearances for...Ch. 27 - What are the minimum size ungrounded conductors...
Ch. 27 - What is the minimum size copper grounding...Ch. 27 - What is the recommended height of a meter socket...Ch. 27 - Prob. 13RCh. 27 - Prob. 14RCh. 27 - Prob. 15RCh. 27 - Prob. 16RCh. 27 - Prob. 17RCh. 27 - Prob. 18RCh. 27 - Prob. 19RCh. 27 - Prob. 20RCh. 27 - Prob. 21RCh. 27 - Prob. 22RCh. 27 - Prob. 23RCh. 27 - Prob. 24RCh. 27 - Prob. 25RCh. 27 - Prob. 26RCh. 27 - Prob. 27RCh. 27 - Prob. 28RCh. 27 - Prob. 29RCh. 27 - Prob. 30RCh. 27 - Prob. 31RCh. 27 - Prob. 32RCh. 27 - Prob. 33RCh. 27 - Prob. 34RCh. 27 - Prob. 35RCh. 27 - Prob. 36RCh. 27 - Prob. 37RCh. 27 - Prob. 38RCh. 27 - Prob. 39RCh. 27 - Prob. 40RCh. 27 - Prob. 42RCh. 27 - Prob. 43RCh. 27 - Prob. 44RCh. 27 - Prob. 45RCh. 27 - Prob. 46RCh. 27 - Prob. 47RCh. 27 - Prob. 48R
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- The recessed fluorescent luminaires installed in the ceiling of the recreation room of this residence are connected with trade size flexible metal conduit. These flexible connections are commonly referred to as fixture whips. Does the flexible metal conduit provide adequate grounding for the luminaires, or must a separate equipment grounding conductor be installed? ________________arrow_forwardHow many circuit wires enter the entry ceiling box? How many equipment grounding conductors enter the entry ceiling box?arrow_forwardWhen a metal junction box is installed as part of the cable wiring to a clothes dryer or electric range, may this box be grounded to the circuit neutral conductor?arrow_forward
- What is the minimum branch-circuit wire size that may be installed in a dwelling?arrow_forwardComplete the wiring diagram for the Recreation Room. Follow the suggested cable layout. Use colored pencils or pens to identify the various colors of the conductor insulation.arrow_forwardIf you use 600-volt rated conductors for Class 2 wiring, does the Code permit pulling these conductors through the same raceway as the power conductors? (Yes) (No) (Circle the correct answer.) Give the NEC section number. ____________arrow_forward
- 16. The _______ point is where the facilities of the serving utility and the premises wiring connect.A. groundedB. neutralC. serviceD. bondingarrow_forward5. If a separate, wire-type equipment grounding conductor (EGC) is used for any reason, the EGC of a grounding-type receptacle must be connected to which of the following?A. The grounding terminal bar outside the service equipment enclosure in a grounded systemB. An EGC that's part of another branch circuit that originates from where the branch circuit for the receptacle originatesC. Any accessible point on the grounding electrode conductorD. The service conductor outside the service equipment enclosure in an ungrounded systemarrow_forwardRefer to the specifications in the back of this text following Chapter 33. a. What electrical codes must be conformed to? ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ b. What is the wiring method to be used in the workshop? ________________________________________________________________________ c. What size conductors are to be used for the lighting branch circuits? ______________________ AWG the small-appliance branch circuits? ______________________ AWG d. What section of the specifications tells us the size of the service entrance to be installed for this residence?arrow_forward
- 6. Which of the following is a condition that a liquidtight flexible metal conduit must meet in order to be suitable as an equipment grounding conductor? A. The conduit is terminated in listed fittings.B. For trade sizes 3/4 through 1 1/4, the conduit conductors contained in the conduit are protected by overcurrent devices rated at 20 amperes or less.C. The combined length of the conduit and other tubing and conduit in the same ground-fault path exceeds six feet. D. For trade sides 3/8 through 1/2, the circuit conductors contained in the conduit are protected by overcurrent devices rated not more than 60 amperes. 7. You're going to connect a surge protection device to a separately derived electrical system. In this situation, the surge protection device should be connected at A. the load side of the first overcurrent protection device. B. the input to the transformer's primary winding.C. the end of the shortest branch circuit.D. the first connected IT cabinet. 8. What is another term…arrow_forwardThe white wire of a cable may be used to connect to a "hot" ungrounded circuit conductor only if ?arrow_forwarda. The Code requires a minimum of two small-appliance circuits in a kitchen. Is it permitted to connect a receptacle in a dining room to one of the kitchen small-appliance circuits? _______________ What Code section applies to this situation? _______________ b. Are outdoor weatherproof receptacles permitted to be connected to a 20-ampere small-appliance circuit? _______________ c. Receptacles located above the countertops in the kitchen must be supplied by at least _______________ 20-ampere small-appliance circuits.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Why HIGH VOLTAGE DC power Transmission; Author: ElectroBOOM;https://www.youtube.com/watch?v=DFQG9kuXSxg;License: Standard Youtube License