The plotting of rate of heat transfer against the convection heat transfer coefficient for the surface emissivities of 0.1, 0.5, 0.8, and 1. Also, discuss the results.
Answer to Problem 100P
The plotting of rate of heat transfer against the convection heat transfer coefficient for the surface emissivities of 0.1, 0.5, 0.8, and 1 are shown in Figure (1) and results are discussed as below.
Explanation of Solution
Calculate the rate of heat transfer by convection.
Here, change in the temperature is
Calculate the rate of heat transfer by radiation.
Here, surface temperature is
Calculate the total rate of heat transfer from the ball.
Conclusion:
Let us solve for
Substitute
Substitute
Substitute 34.35 W for
Follow the above process to calculate the rate of heat transfer against the convection heat transfer coefficient for the surface emissivities of 0.1 and 0.5 using spreadsheet including equations (I), (II), and (III) as in table (1).
5 | 11.4511 | 2.04127 | 13.4924 | 10.2064 | 21.6575 |
7.5 | 17.1767 | 2.04127 | 19.2179 | 10.2064 | 27.383 |
10 | 22.9022 | 2.04127 | 24.9435 | 10.2064 | 33.1086 |
12.5 | 28.6278 | 2.04127 | 30.669 | 10.2064 | 38.8341 |
15 | 34.3533 | 2.04127 | 36.3946 | 10.2064 | 44.5597 |
17.5 | 40.0789 | 2.04127 | 42.1201 | 10.2064 | 50.2852 |
20 | 45.8044 | 2.04127 | 47.8457 | 10.2064 | 56.0108 |
22.5 | 51.53 | 2.04127 | 53.5712 | 10.2064 | 61.7363 |
25 | 57.2555 | 2.04127 | 59.2968 | 10.2064 | 67.4619 |
27.5 | 62.9811 | 2.04127 | 65.0224 | 10.2064 | 73.1874 |
30 | 68.7066 | 2.04127 | 70.7479 | 10.2064 | 78.913 |
Continue table (1) for
16.3302 | 27.7813 | 20.4127 | 31.8638 |
16.3302 | 33.5068 | 20.4127 | 37.5894 |
16.3302 | 39.2324 | 20.4127 | 43.3149 |
16.3302 | 44.9579 | 20.4127 | 49.0405 |
16.3302 | 50.6835 | 20.4127 | 54.766 |
16.3302 | 56.4091 | 20.4127 | 60.4916 |
16.3302 | 62.1346 | 20.4127 | 66.2172 |
16.3302 | 67.8602 | 20.4127 | 71.9427 |
16.3302 | 73.5857 | 20.4127 | 77.6683 |
16.3302 | 79.3113 | 20.4127 | 83.3938 |
16.3302 | 85.0368 | 20.4127 | 89.1194 |
Show the plotting of rate of heat transfer against the convection heat transfer coefficient for the surface emissivities of 0.1, 0.5, 0.8, and 1.0 using Table (1) and (2) as in Figure (1).
Want to see more full solutions like this?
Chapter 2 Solutions
CONNECT FOR THERMODYNAMICS: AN ENGINEERI
- Consider a person standing in a room at 23°C. Determine the total rate of heat transfer from this person if the exposed surface area and the skin temperature of the person arel.7 m2 and 32°C, respectively, and the convection heat transfer coefficient is 5 W/m2· °C. Take the emissivity of the skin and the clothes to be 0.9, and assume the temperature of the inner surfaces of the room to be the same as the air temperature.arrow_forwardDetermine the rate of heat loss from the pipe by natural convection, in kW. 18. An aluminum pan whose thermal conductivity is 237 W/m · °C has a flat bottom whose diameter is 20 cm and thickness 0.4 cm. Heat is transferred steadily to boiling water in the pan through its bottom at a rate of 500 W. If the inner surface of the bottom of the pan is 105°C, determine the temperature of the outer surface of the bottom of the pan.arrow_forwardThe inner and outer glasses of a 2-m × 2-m double pane window are at 18°C and 6°C, respectively. If the 1-cm space between the two glasses is filled with still air, determine the rate of heat transfer through the air layer by conduction, in kW.arrow_forward
- Calculate the quantity of heat to be transferred in BTU to 3 kg of brass to raise its temperature from 26.7°C to 239.9°C The specific heat of the brass is 0.394 kJ/kg k. answer in 3 decimal places.arrow_forwardA 3-m2 hot black surface at 80°C is losing heat to the surrounding air at 25°C by convection with a convection heat transfer coefficient of 12 W/m2 ·°C, and by radiation to the surrounding surfaces at 15°C. The total rate of heat loss from the surface is (a) 1987 W (b) 2239 W (c) 2348 W (d) 3451 W (e) 3811 Warrow_forwardA 2-kW electric resistance heater in a room is turned on and kept on for 30 min. The amount of energy transferred to the room by the heater isarrow_forward
- 3-26 Consider a person standing in a room at 20°C with an exposed surface area of 1.7 m². The deep body temperature of the human body is 37°C, and the thermal conductivity of the human tissue near the skin is about 0.3 W/m · °C. The body is losing heat at a rate of 150 W by natural convection and radia- tion to the surroundings. Taking the body temperature 0.5 cm beneath the skin to be 37°C, determine the skin temperature of the person.arrow_forwardTransPipe company is going to transport a flammable liquid. It is known that this liquid is being transported in a pipe (I.D=10 m) where heat (20 kW) is added to the liquid. The specific heat and density of this liquid are given as 2.5 kJ/kg.K and 790 kg/m², respectively. The volume flow rate of the liquid that is necessary to keep the liquid temperature below its flashpoint (16 °C) is to be determined. Assume steady operating conditions exist and fluid properties are constant. Determine: (1) the minimum volume flow rate of the liquid to maintain the liquid in the pipe well below its flashpoint. (2) If the company wants to reduce the minimum volume flow rate below your calculated minimum volume flow rate, what can they retrofit? You as an engineer, give them one suggestion (less than 20 words). Liquid T = 10°C Toutarrow_forwardA 1000-W iron is left on the ironing board with its base exposed to the air at 23°C. The convection heat transfer coefficient between the base surface and the surrounding air is 20 W/m2 ·°C. If the base has an emissivity of 0.4 and a surface area of 0.02 m2 , determine the temperature of the base of the iron.arrow_forward
- Principles of Heat Transfer (Activate Learning wi...Mechanical EngineeringISBN:9781305387102Author:Kreith, Frank; Manglik, Raj M.Publisher:Cengage Learning