Textbook Question
Chapter 29, Problem 8R
What is the calculated load when fixed electric heating is used in a residence? (220.51)
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
What is the minimum General lighting load for a 11750 square-foot nightclub with an actual connected lighting load of 14060 vA
List the equipment in detail with rating for substation and swictchgear installation.
A homeowner wants to add 12 general-purpose receptacle outlets to the electrical drawings before the house is built, what additional load, in volt-amperes will they add to the service load calculation?
Chapter 29 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Ch. 29 - Prob. 1RCh. 29 - a. What is the unit load per ft2 for the general...Ch. 29 - a. What is the ampere rating of the circuits that...Ch. 29 - Why is the air-conditioning load for this...Ch. 29 - What demand factor may be applied when four or...Ch. 29 - What load may be used for an electric range rated...Ch. 29 - What is the calculated load for an electric range...Ch. 29 - What is the calculated load when fixed electric...Ch. 29 - On what basis is the neutral conductor of a...Ch. 29 - Why is it permissible to omit an electric space...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- when calculating a dwelling lighting load on the "volt-ampere per ft2" basis, the receptacle load used for floor lamps, table lamps, and so fourtharrow_forwardWhen calculating a dwelling lighting load on the "volt-ampere per ft" basis, the receptacle load used for floor lamps, table lamps, and so forth arearrow_forwardWhat demand factor may be applied when four or more fixed appliances are connected to a service, in addition to an electric range, air conditioner, clothes dryer, or space-heating equipment? (220.53) ____arrow_forward
- a. What is the minimum power demand allowed by the Code for an electric dryer if no actual rating is available for the purpose of calculating feeder and service-entrance conductor sizing? ______________ b. What is the current draw? _____________________arrow_forwardWhat is the estimated demand load for general lighting and general-use receptacles in a 24-room motel, where each unit has an area of 700 square feet?arrow_forwardwhat is the receptacle demand load for a 9600 square foot office building with 52 receptaclesarrow_forward
- An eighteen-unit multifamily dwelling contains the following appliances in each unit : a 1-kVA, 115-volt dishwasher, a 1/3 hp, 115-volt in-sink waste disposer and a 4500-watt, 230 volt water heater. Using the standard method, what is the service neutral load contribution, in volt-amperes , for these appliances ? ( Assume water heater watt rating equivalent to volt-ampere )arrow_forwardCan two 25,000-Btu room air conditioners be wired into the same electricalcircuit protected by a 25-ampere fuse? Each air conditioner is rated at 3,050watts for a 230-volt circuit. (This rating is while the air conditioner is runningsteadily.)arrow_forwardCalculate the voltage drop of a 120/240 volts, three wire underground residential service installed with 2 AWG aluminum URD cable if the load is 80 amps and the one way length of the underground service conductor is 100 feet.arrow_forward
- Explain how electricty power is generated and tramnsimitted to customer unit. Show The single line diagram of a typical distribution system. Also Explain different methods of electricity distribution and the equipment used for different methods of electrical distribution.arrow_forwardWhat spaces are not included in the floor area when computing the load in volt-amperes per square foot?arrow_forwardYou have determined that a 4700-ohm, 1/2-watt resistor on an electronic circuit board is defective. Assuming room permits, can the resistor be replaced with a 4700-ohm, 1-watt resistor without damage to the rest of the board, or will the higher wattage resistor generate excessive heat that could damage other components?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENTElectricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning
What is an electric furnace and how does it work?; Author: Fire & Ice Heating and Air Conditioning Inc;https://www.youtube.com/watch?v=wjAWecPGi0M;License: Standard Youtube License