Electric machinery fundamentals
5th Edition
ISBN: 9780073529547
Author: Chapman, Stephen J.
Publisher: MCGRAW-HILL HIGHER EDUCATION
expand_more
expand_more
format_list_bulleted
Concept explainers
Textbook Question
Chapter 3, Problem 3.6P
A three-phase, Y-connected, 60 Hz, two-pole synchronous machine has a stator with 5000 turns of wire per phase. What rotor flux would be required to produce a terminal (line-to-line) voltage of 13.2 kV?
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A 3-phase, 2-pole-pair, induction machine operates at 1450 revolutions per minute when fed from a 50Hz supply at 240rmsV phase voltage. If the air-gap flux linkage of the machine is kept approximately constant when the supply frequency Is 41 Hz, the rms phase voltage of the machine should be ?
3-phase,50 Hz, delta connected generator, its stator winding having 12 slots per pole pair and 6 conductors in each, if the total air gap flux is 160mwb. Find the terminal voltage. The prime mover speed is 750rpm.
A 2-pole, 50 Hz, 3-phase, turbo-alternator is excited to generate the busbar voltage of 11 kV on no load. The machine is star-connected and the short circuit current for this excitation is 1000 A. Calculate the synchronizing power per degree of mechanical displacement of the rotor and the corresponding synchronizing torque.
Chapter 3 Solutions
Electric machinery fundamentals
Ch. 3 - What is the principal difference between a...Ch. 3 - Prob. 3.2QCh. 3 - Prob. 3.3QCh. 3 - What is the equation for the induced torque in an...Ch. 3 - The simple loop rotating in a uniform magnetic...Ch. 3 - Prob. 3.2PCh. 3 - The first ac power system in the United States ran...Ch. 3 - A three-phase, Y-connected, four-pole winding is...Ch. 3 - A three-phase, -connected, six-pole winding is...Ch. 3 - A three-phase, Y-connected, 60 Hz, two-pole...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A three-phase alternator, 20 kV, synchronous has a reactance of 10Ω and a negligible resistance. The machine draws an armature current of 150A, 0.80 pf lagging. If the steam admission is constant and field current isadjusted raising the induced emf by 25 %, find the new armature current.arrow_forwardThe stator of a three-phase, 60-Hz, 8 pole synchronous generator has 48 slots. Determine (a) the speed of the rotor, (b) the number of coils in a phase group, (c) the slot pitch, and (d) the coil pitch. Sketch the winding arrangement for two phase groups.arrow_forwardA 3-phase star connected, 6 pole synchronous machine has 36 slots. Show the distribution of winding for each phase separately (Not combined). Find the distribution factor and pitch factor.arrow_forward
- A 4 pole dc generator runs at 750 rpm and generates an emf of 240 V. The armature is wave wound and has 792 conductors. If the total flux from each pole is 0.0145 Wb, If leakage coefficient is given as the ratio of the total flux/pole to the working flux per pole, find its value.arrow_forward3.An induction motor has a rotor resistance and reactance at standstill of 0.1 ohm and 3.5 ohm respectively. At standstill the voltage induced to the rotor is 60volts per phase. If the slip is 5%, determine the rotor currentarrow_forwarda four pole dc generator has an armature winding containing a total of 648 conductors connected in 3 parallel paths. if the flex pole is .321x10^6 maxwells. and speed is 1800 rpm. calculate the average generated voltagearrow_forward
- A 54-slot stator of a synchronous generator is wound for three-phase, 50-Hz, 6-pole applications. Determine (a) the number of coils in a phase group, (b) the slots per pole, (c) the slot span, (d) the coil span, and (e) the speed at which the rotor must be rotated.arrow_forwardEvaluate the emf generated in a 6-pole, lap wound DC machine having flux/pole equal to 0.3 wb rotating at 1800 rpm? (No. of coil sides = 100) Option 1: 500 V Option 2: 300 V Option 3: 600 V Option 4: 900Varrow_forwardThe stator of a 3? , 8-poles machine has 96 stator slots and short-pitched by 9/12.The airgap flux density shows that third and fifth harmonics are present and are of amplitude30 and 15 percent of the fundamental. Determine the ratio of the line-to-line voltage and linenatural voltagearrow_forward
- A 6 pole, 50kW, 500 Volts wave-connected dc compound generator has 492 conductors on its armature.The brushes are shifted by an angle of 9 mechanical degrees to eliminate sparking on the commutatorwhen delivering full-load current. What is the respective cross-magnetizing and demagnetizing amp-turnsper pole?arrow_forwardASAP a.) In a separately excited dc generator, if the current in the field winding increases, the terminal voltage of the machine _______. b.) If the value of the field flux in a dc generator increases, the generated emf will ________. choices: increase, decrease, the same, zeroarrow_forwardThe stator of a three-phase, 60-Hz, %pole synchronous generator has 48 slots. Determine (a) the speed of the rotor, (b) the number of coils in a phase group, (c) the coil pitch, and (d) the slot pitch. Sketch the complete winding arrangement of the stator.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Electricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage Learning
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning
How Electric Motors Work - 3 phase AC induction motors ac motor; Author: The Engineering Mindset;https://www.youtube.com/watch?v=59HBoIXzX_c;License: Standard Youtube License